DATASHEET CLP0512 Open Frame Power Supply 90 - 265Vac Input 12Vdc Output 550W Output Power 5V Standby 5V 1A Description In a s l 3 x 6-inch footprint, the 12Vdc open frame power supply delivers greater than 90 typical power efficien cy and 450W capability at 45C and 1m/s airflow with derating at higher temperatures or lower airflows. Protection features include output overvoltage and (OTP). Applications include: Industrial Equipment Telecommunications Equipment Networks, Routers, Switchers Features Compact size 76.2 mm x 152.4 mm x 35 mm (3 in x 6 in x Output overvoltage protection 3 1.38 in) with density of 21.8 W/in Minimum of 11ms of holdup time at 550W out Universal AC Input Range (90 - 265VAC ) Parallelable with output current sharing Output voltage of 12V (adjustable 5%) Active power factor corrected input Standby output of 5V 1A Conducted EMI - meets CISPR22 (EN55022) and FCC Class Maximum output current of 45.8A 12Vout (550W) B requirements High efficiency (>90% at Full Load, 230VAC in ) Meets IEC61000-4-5, Level 4 (2kV/4kV) and ANSI C62.41 (6kV) 550W capability at 115 V , 50 ambient, 400lfm airflow IN with derating at higher temperatures or lower airflows Compliant to RoHS II EU Directive 2011/65/EU 420W output at 90 V for sealed enclosure applications, UL and cUL approved to UL/CSA60950-1, TUV IN with enclosure outside surface temp at 55 and (EN60950-1), CE Mark (for LVD) and CB Report available enclosure inside ambient at 85 ISO** 9001 and ISO 14001 certified manufacturing facilities Output overcurrent protection (non-latching) AC OK signal Overtemperature protection Dual input fusing option - Line & Return See footnotes on page 4 Page 1 2020 ABB. All rights reserved. Technical Specifications Absolute Maximum Ratings Stresses over the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions over those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous Operation All 90 265 Vac For up to 10 seconds operation All 90 275 Vac Operating Ambient Temperature All -40 85 C (see Thermal Considerations section) Storage Temperature All -40 85 C Humidity (non-condensing) All 5 95 % Altitude All 5000 m Isolation VoltageInput to output All 3000 Vac Input to safety ground All 1500 Vac Outputs to safety ground All 50 Vac Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 265 Vac Input Source Frequency All 47 50/60 63 Hz Input Current (V = 90Vac) All 6.8 A IN RMS Input Power Factor (230Vac, Full Load) All 0.95 Inrush Transient Current (V = 265Vac, T = 25C) All 60 A Peak IN amb Leakage Current to earth ground (V = 265Vac) All 3.5 mA IN Output Voltage Setpoint All 12 Vdc Output Voltage Tolerance (due to set point, temperature variations, load All -2 2 % and line regulation) Output Voltage Adjustment Range All 11.4 12.6 Vdc Output Remote Sense Range All 250 mVdc Output Load Regulation All 1 %Vout Output Line Regulation All 0.5 %Vout Output Ripple and Noise measured with 0.1F ceramic capacitor and 10F electrolytic capacitor in parallel Peak-to-peak (20MHz All 180 mV p-p o Bandwidth output ripple specification is met over 0to 85 C) Dynamic Load Response 50% to 100% load transient, 1A/s slew rate Output voltage deviation All 5% % Settling Time All 500 s Output Current All 0 45.8 Adc Output Current Limit Inception All 110 145 % I O,max Maximum Output Capacitance All 10000 F Standby Output Voltage All except 5 Vdc Standby Output Current All except 1 Adc -continued on next page- See footnotes on page 4 Page 2 2020 ABB. All rights reserved.