F200 Series Residual current devices UL 1053 residual current devices The F200 product range is approved as a UL 1053 recognized component. ABB recommends the installation of F200 RCDs wherever uptime is a critical factor. F200 Residual current devices Product range The F200 series includes 2 and 4-pole devices designed to protect against AC ground faults (AC type) and both AC and pulsating DC ground faults (A type). AP-R models provide high resistance to nuisance tripping. Selective S models provide an intentional trip delay. F200 AC Type Catalog number Description Catalog number Description F204AC-40/0.03 RCD F200 4P 40A 30mA AC F202AC-16/0.01 RCD F200 2P 16A 10mA AC F204AC-63/0.1 RCD F200 4P 63A 100mA AC F202AC-25/0.03 RCD F200 2P 25A 30mA AC F204AC-80/0.03 RCD F200 4P 80A 30mA AC F202AC-40/0.03 RCD F200 2P 40A 30mA AC F204AC-100/0.03 RCD F200 4P 100A 30mA AC F202AC-63/0.03 RCD F200 2P 63A 30mA AC F202AC-80/0.03 RCD F200 2P 80A 30mA AC F204AC-125/0.03 1 RCD F200 4P 125A 30mA AC F202AC-100/0.03 RCD F200 2P 100A 30mA AC F204AC-25/0.1 RCD F200 4P 25A 100mA AC F202AC-25/0.1 RCD F200 2P 25A 100mA AC F204AC-40/0.1 RCD F200 4P 40A 100mA AC F202AC-40/0.1 RCD F200 2P 40A 100mA AC F204AC-63/0.1 RCD F200 4P 63A 100mA AC F202AC-63/0.1 RCD F200 2P 63A 100mA AC F204AC-80/0.1 RCD F200 4P 80A 100mA AC F204AC-100/0.1 RCD F200 4P 100A 100mA AC F202AC-80/0.1 RCD F200 2P 80A 100mA AC RCD F200 4P 125A 100mA AC F202AC-100/0.1 RCD F200 2P 100A 100mA AC F204AC-125/0.1 1 F202AC-25/0.3 RCD F200 2P 25A 300mA AC F204AC-25/0.3 RCD F200 4P 25A 300mA AC F202AC-40/0.3 RCD F200 2P 40A 300mA AC F204AC-40/0.3 RCD F200 4P 40A 300mA AC F202AC-63/0.3 RCD F200 2P 63A 300mA AC F204AC-63/0.3 RCD F200 4P 63A 300mA AC F202AC-80/0.3 RCD F200 2P 80A 300mA AC F204AC-80/0.3 RCD F200 4P 80A 300mA AC F202AC-100/0.3 RCD F200 2P 100A 300mA AC F204AC-100/0.3 RCD F200 4P 100A 300mA AC F202AC-25/0.5 RCD F200 2P 25A 500mA AC F204AC-125/0.3 1 RCD F200 4P 125A 300mA AC F202AC-40/0.5 RCD F200 2P 40A 500mA AC F204AC-25/0.5 RCD F200 4P 25A 500mA AC F202AC-63/0.5 RCD F200 2P 63A 500mA AC F204AC-40/0.5 RCD F200 4P 40A 500mA AC F202AC-80/0.5 RCD F200 2P 80A 500mA AC F204AC-63/0.5 RCD F200 4P 63A 500mA AC F202AC-100/0.5 RCD F200 2P 100A 500mA AC F204AC-80/0.5 RCD F200 4P 80A 500mA AC F204AC-25/0.03 RCD F200 4P 25A 30mA AC F204AC-100/0.5 RCD F200 4P 100A 500mA AC F204AC-125/0.5 1 RCD F200 4P 125A 500mA AC F200 A Type Catalog number Description Catalog number Description F204A-25/0.03 RCD F200 4P 25A 30mA A F202A-16/0.01 RCD F200 2P 16A 10mA A F204A-40/0.03 RCD F200 4P 40A 30mA A F202A-25/0.03 RCD F200 2P 25A 30mA A F202A-40/0.03 RCD F200 2P 40A 30mA A F204A-63/0.03 RCD F200 4P 63A 30mA A F202A-63/0.03 RCD F200 2P 63A 30mA A F204A-80/0.03 RCD F200 4P 80A 30mA A F204A-100/0.03 RCD F200 4P 100A 30mA A F202A-80/0.03 RCD F200 2P 80A 30mA A F204A-125/0.03 1 RCD F200 4P 125A 30mA A F202A-100/0.03 RCD F200 2P 100A 30mA A F204A-25/0.1 RCD F200 4P 25A 100mA A F202A-25/0.1 RCD F200 2P 25A 100mA A F204A-40/0.1 RCD F200 4P 40A 100mA A F202A-40/0.1 RCD F200 2P 40A 100mA A F204A-63/0.1 RCD F200 4P 63A 100mA A F202A-63/0.1 RCD F200 2P 63A 100mA A F202A-80/0.1 RCD F200 2P 80A 100mA A F204A-80/0.1 RCD F200 4P 80A 100mA A F202A-100/0.1 RCD F200 2P 100A 100mA A F204A-100/0.1 RCD F200 4P 100A 100mA A F202A-25/0.3 RCD F200 2P 25A 300mA A F204A-125/0.1 1 RCD F200 4P 125A 100mA A F204A-25/0.3 RCD F200 4P 25A 300mA A F202A-40/0.3 RCD F200 2P 40A 300mA A F204A-40/0.3 RCD F200 4P 40A 300mA A F202A-63/0.3 RCD F200 2P 63A 300mA A F204A-63/0.3 RCD F200 4P 63A 300mA A F202A-80/0.3 RCD F200 2P 80A 300mA A F204A-80/0.3 RCD F200 4P 80A 300mA A F202A-100/0.3 RCD F200 2P 100A 300mA A F202A-25/0.5 RCD F200 2P 25A 500mA A F204A-100/0.3 RCD F200 4P 100A 300mA A F202A-40/0.5 RCD F200 2P 40A 500mA A F204A-125/0.3 1 RCD F200 4P 125A 300mA A F202A-63/0.5 RCD F200 2P 63A 500mA A F204A-25/0.5 RCD F200 4P 25A 500mA A F202A-80/0.5 RCD F200 2P 80A 500mA A F204A-40/0.5 RCD F200 4P 40A 500mA A F202A-100/0.5 RCD F200 2P 100A 500mA A F204A-63/0.5 RCD F200 4P 63A 500mA A 1 125A versions are not UL approved. 1 125A versions are not UL approved.F200 A Type, cont. Catalog number Description Catalog number Description F204A-80/0.5 RCD F200 4P 80A 500mA A F202AS-40/0.5 RCD F200 2P 40A 500mA A S F204A-100/0.5 RCD F200 4P 100A 500mA A F202AS-63/0.5 RCD F200 2P 63A 500mA A S F204A-125/0.5 1 RCD F200 4P 125A 500mA A F202AS-100/0.5 RCD F200 2P 100A 500mA A S F202A-25/0.03APR RCD F200 2P 25A 30mA A AP-R F202AS-40/1.0 RCD F200 2P 40A 1000mA A S F202A-40/0.03APR RCD F200 2P 40A 30mA A AP-R F202AS-63/1.0 RCD F200 2P 63A 1000mA A S F202A-63/0.03APR RCD F200 2P 63A 30mA A AP-R F202AS-100/1.0 RCD F200 2P 100A 1000mA A S F202A-80/0.03APR RCD F200 2P 80A 30mA A AP-R F204AS-40/0.1 RCD F200 4P 40A 100mA A S F202A-100/0.03APR RCD F200 2P 100A 30mA A AP-R F204AS-63/0.1 RCD F200 4P 63A 100mA A S F204A-25/0.03APR RCD F200 4P 25A 30mA A AP-R F204AS-100/0.1 RCD F200 4P 100A 100mA A S F204AS-40/0.3 RCD F200 4P 40A 300mA A S F204A-40/0.03APR RCD F200 4P 40A 30mA A AP-R F204A-63/0.03APR RCD F200 4P 63A 30mA A AP-R F204AS-63/0.3 RCD F200 4P 63A 300mA A S F204A-80/0.03APR RCD F200 4P 80A 30mA A AP-R F204AS-100/0.3 RCD F200 4P 100A 300mA A S F204A-100/0.03APR RCD F200 4P 100A 30mA A AP-R F204AS-125/0.3 1 RCD F200 4P 125A 300mA A S F204A-125/0.03APR 1 RCD F200 4P 125A 30mA A AP-R F204AS-40/0.5 RCD F200 4P 40A 500mA A S F202AS-40/0.1 RCD F200 2P 40A 100mA A S F204AS-63/0.5 RCD F200 4P 63A 500mA A S F202AS-63/0.1 RCD F200 2P 63A 100mA A S F204AS-100/0.5 RCD F200 4P 100A 500mA A S RCD F200 4P 125A 500mA A S F202AS-100/0.1 RCD F200 2P 100A 100mA A S F204AS-125/0.5 1 F202AS-40/0.3 RCD F200 2P 40A 300mA A S F204AS-40/1.0 RCD F200 4P 40A 1000mA A S F202AS-63/0.3 RCD F200 2P 63A 300mA A S F204AS-63/1.0 RCD F200 4P 63A 1000mA A S F202AS-100/0.3 RCD F200 2P 100A 300mA A S F204AS-100/1.0 RCD F200 4P 100A 1000mA A S 1 125A versions are not UL approved. Technical data Item F200AC F200A Standards UL 1053 1053 CSA - - VDE - - IEC 61008 61008 Number of poles 2, 4 2, 4 1 1 Rated currents 16, 25, 40, 63, 80, 100, 125 A 16, 25, 40, 63, 80, 100, 125 A Operating voltage 480Y/277 VAC 480Y/277 VAC Sensitivity In 10, 30, 100, 300, 500, 1000 mA 10, 30, 100, 300, 500, 1000 mA Pick up current 0.65 x Sensitivity In 0.65 x Sensitivity In Rated conditional short-circuit current 10 kA 10 kA 2 Inc=Ic with gG fuse 100 A Rated residual breaking capacity I m=Im 1 kA 1 kA Working temperature -25...+55C -25...+55C CPI yes yes Protection category IP20 IP20 Depth of unit per DIN 43880 68 mm/ 2.68 in. 68 mm/ 2.68 in. Mounting position vertical, horizontal vertical, horizontal Standard mounting 35 mm DIN rail 35 mm DIN rail 1 125 A versions are not UL approved. 2 For 125 A F200, the fuse is gG 125 A Item F200A AP-R F200A S Standards UL 1053 1053 CSA - - VDE - - IEC 61008 61008 Number of poles 2, 4 2, 4 1 1 Rated currents 25, 40, 63, 80, 100, 125 A 40, 63, 100, 125 A Operating voltage 480Y/277 VAC 480Y/277 VAC Sensitivity In 10, 30, 100, 300, 500, 1000 mA 10, 30, 100, 300, 500, 1000 mA Pick up current 0.65 x Sensitivity In 0.65 x Sensitivity In Rated conditional short-circuit current 10 kA 10 kA 2 Inc=Ic with gG fuse 100 A Rated residual breaking capacity I m=Im 1 kA 1 kA Working temperature -25...+55C -25...+55C CPI yes yes Protection category IP20 IP20 Depth of unit per DIN 43880 68 mm/ 2.68 in. 68 mm/ 2.68 in. Mounting position vertical, horizontal vertical, horizontal Standard mounting 35 mm DIN rail 35 mm DIN rail 1 125 A versions are not UL approved. 2 For 125 A F200, the fuse is gG 125 A ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-1441 Web: www.abb.us/lowvoltage 1SXU430065L0201 Rev.C April 2013