Data Sheet GE FLP0412FPx Open Frame Power Supply 90 - 265Vac input 2-4 outputs 450W Output Power Features Compact size 76.2 mm x 178 mm x 36.8 mm 3 (3 in x 7 in x 1.45 in) with density of 15 W/in Universal AC Input Range (90 265VAC) Output voltages of +12V (adjustable 5%), +24V (adjustable 16-34V), +5V (adjustable 1-5.5V), +3.3V (adjustable 1-5.5V) Standby output of 5V 1A Maximum output current of 37.5A12V, 2A24V, 12A5V, 12A3.3V (450W total, see description below) High efficiency (>91% at Full Load, 230VAC in) Full load capability at 42C and 1m/s airflow with derating at higher temperatures or lower airflows Capable of 320W out in sealed enclosure applications with enclosure ambient at 55C Output overcurrent protection (non-latching) Overtemperature protection Applications Output overvoltage protection Industrial equipment Minimum of 11ms of holdup time at 450W out Parallelable with output current sharing on main 12V Telecommunications equipment output option, please request details Active power factor corrected input Conducted EMI - meets CISPR22 (EN55022/EN55032) and FCC Class B requirements Meets IEC61000-4-5, Level 4 (2kV/4kV) Compliant to RoHS EU Directive 2002/95/EC UL and cUL approved to UL/CSA60950-1, TUV (EN60950- 1), CE Mark (for LVD) and CB Report available ISO** 9001 and ISO 14001 certified manufacturing facilities Description In a small 3 x 7 inch footprint, the 450W 2-4 output FLP0412x open frame power supply delivers greater than 90 percent typical power efficiency and full load output at 42C and 1m/s airflow. Protection features include output overcurrent (OCP), overvoltage (OVP), and overtemperature (OTP). There is power trading between the outputs. Whatever power is going to be taken from V2, V3, and V4, should be deducted from the gross power available from V1. This unit also offers PMBus control and monitoring of V3 and V4. Use of this feature is optional. * U L is a registered trademark of Underwriters Laboratories, Inc. C SA is a registered trademark of Canadian Standards Association. VD E is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards December 1, 2017 2017 General Electric Corporation. All rights reserved. Data Sheet GE FLP0412FPx Open Frame Power Supply 90 - 265Vac input 2-4 outputs 450W Output Power Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Min Max Unit Input Voltage - Continuous All 90 265 Vac For up to 10 seconds All 90 275 Vac Operating Ambient Temperature All -40 85 C (see Thermal Considerations section) Storage Temperature All -40 85 C Humidity (non-condensing) All 5 95 % Altitude All 5000 m Isolation Voltage Input to output All 3000 Vac Input to safety ground All 1500 Vac All Outputs to safety ground 50 Vac Electrical Specifications Parameter Device Min Typ Max Unit Operating Input Voltage All 90 115/230 265 Vac Input Source Frequency All 47 50/60 63 Hz Input Current (V = 90Vac) All 6 A IN RMS Input Power Factor (230Vac, Full Load) All 0.95 Inrush Transient Current (V = 265Vac, T = 25C) All 60 A Peak IN amb Leakage Current to earth ground (V = 265Vac) All 3.5 mA IN V1 Output Voltage Setpoint All 12 Vdc V1 Output Voltage Tolerance (due to set point, temperature variations, All -2 2 % load and line regulation) V1 Output Voltage Adjustment Range All 11.4 12.6 Vdc V1 Output Remote Sense Range All 250 mVdc V1 Output Load Regulation All 1 %Vout V1 Output Line Regulation All 0.5 %Vout V1 Output Ripple and Noise measured with 0.1F ceramic capacitor in parallel with 470F electrolytic capacitor All 240 mV p-p Peak-to-peak (20MHz Bandwidth) V1 Dynamic Load Response 50% to 100% transient, 1A/s slew rate Output voltage deviation All 5% % Settling Time All 500 s V1 Output Current gross see page 1 All 0 37.5 Adc V1 Output Current Limit Inception All 105 145 % IO,max V1 Maximum Output Capacitance All 10000 F Standby Output Voltage All 5 Vdc Standby Output Current All 1 Adc Efficiency: VIN = 230Vac, 20% load All 84.5 % 50% load All 91.3 % 100% load All 91.9 % VIN = 115Vac, 20% load All 83.5 % 50% load All 89.9 % 100% load All 90 % 1 Holdup Time VIN = 115Vac, 450W load All 11 ms VIN = 230Vac, 450W load All 11 ms 1 Holdup time may be lower at cold temperatures December 1, 2017 2017 General Electric Corporation. All rights reserved. Page 2