Data Sheet GE TM 12A Digital SlimLynx : Non-Isolated DC-DC Power Modules 3Vdc 14.4Vdc input 0.45Vdc to 5.5Vdc output 12A Output Current Features Compliant to RoHS II EU Directive 2011/65/EU Compliant to REACH Directive (EC) No 1907/2006 Compliant to IPC-9592 (September 2008), Category 2, Class II Ultra low height design for very dense power applications. High technology encapsulation for improved thermal performance, electrical insulation, and easy manufacturing. RoHS Compliant Small size: 20.32 mm x 11.43 mm x 3 mm (Max) (0.8 in x 0.45 in x 0.118 in) Output voltage programmable from 0.6Vdc to 5.5Vdc via external resistor. Digitally adjustable down to Applications 0.45Vdc Distributed power architectures Wide Input voltage range (3Vdc-14.4Vdc) Wide operating temperature range -40C to 105C . See Intermediate bus voltage applications derating curves Telecommunications equipment DOSA approved footprint Servers and storage applications TM Digital interface through the PMBus protocol Networking equipment TM Tunable Loop to optimize dynamic output voltage response Industrial equipment Flexible output voltage sequencing EZ-SEQUENCE Vin+ Vout+ VIN VOUT Power Good signal VS+ PGOOD RTUNE Remote On/Off MODULE SEQ Fixed switching frequency with capability of external CTUNE synchronization CLK Cin TRIM Co DATA Output overcurrent protection (non-latching) ADDR0 SMBALRT RTrim ADDR1 Overtemperature protection ON/OFF RADDR1 RADDR0 Ability to sink and source current SIG GND SYNC GND VS- Compatible in a Pb-free or SnPb reflow environment GND UL* 60950-1Recognized, CSA C22.2 No. 60950-1-03 Certified, and VDE 0805:2001-12 (EN60950-1) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities Description TM The 12A Digital SlimLynx power modules are non-isolated dc-dc converters that can deliver up to 12A of output current. These modules operate over a wide range of input voltage (VIN = 3Vdc-14.4Vdc) and provide a precisely regulated output voltage from 0.45Vdc to 5.5Vdc, programmable via an external resistor and PMBus control. Features include a digital interface using the PMBus protocol, remote On/Off, adjustable output voltage, over current and over temperature protection. The PMBus interface supports a TM range of commands to both control and monitor the module. The module also includes the Tunable Loop feature that allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to savings on cost and PWB area. * UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards The PMBus name and logo are registered trademarks of the System Management Interface Forum (SMIF) June 15, 2016 2016 General Electric Company. All rights reserved. GE Data Sheet TM 12A Digital SlimLynx : Non-Isolated DC-DC Power Modules 3Vdc 14.4Vdc input 0.45Vdc to 5.5Vdc output 12A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All V -0.3 15 V IN Continuous SEQ, SYNC, VS+ All 7 V CLK, DATA, SMBALERT All 3.6 V Operating Ambient Temperature All T -40 85 C A (see Thermal Considerations section) Storage Temperature All T -55 125 C stg Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All V 3 14.4 Vdc IN Maximum Input Current All I 10A Adc IN,max (V =3V to 14V, I =I ) IN O O, max V = 0.6 Vdc I 50 mA O,set IN,No load Input No Load Current (VIN = 12Vdc, IO = 0, module enabled) V = 5Vdc I 220 mA O,set IN,No load Input Stand-by Current All IIN,stand-by 20 mA (V = 12Vdc, module disabled) IN 2 2 Inrush Transient All I t 1 A s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1H source impedance VIN =0 to All 50 mAp-p 14V, IO= IOmax See Test Configurations) Input Ripple Rejection (120Hz) All -55 dB June 15, 2016 2016 General Electric Company. All rights reserved. Page 2