ULTRAVOLT M SERIES MINIATURE, MICRO-SIZED HIGH VOLTAGE BIASING SUPPLIES The miniature, micro-sized M series is the ideal solution for applications requiring biasing voltage ranging from 0 to 3000 V and very small currentonly 16.4 cc 3 (1.00 in ). Less than 12.7 mm (0.5 ) high, these modules are ideal for low-profile applications. PRODUCT HIGHLIGHTS Seven models from 0 to 600, 1000, 1250, 1500, 2000, 2500, or 3000 V Output power: 0.5, 0.8, or 1 W Tight line/load regulation Arc and continuous short circuit protection Self-restoring output voltage Low cost Miniature and lightweight Voltage monitoring Low ripple (0.01% peak to peak) Optional flying lead UL/cUL recognized, IEC-60950-1, CE Mark (LVD and RoHS) TYPICAL APPLICATIONS Bias supplies Electrostatic chucks Hand held x-ray florescence (XRF) Avalanche photo diodes (APD) Photomultiplier tubes (PMT) Silicon detector (SiD) X-ray flat panel detector (FPD) 2019 Advanced Energy Industries, Inc. Ionization chamber detectorULTRAVOLT M SERIES ELECTRICAL SPECIFICATIONS Parameter Specifications Units Input Voltage Vin 5 0.5 (2 to 3 kV ONLY) 12 1 15 1 (600 V 24 2 VDC (Pins 1 and 2) to 1.5 kV ONLY) Input Voltage 5 (2 to 3 kV ONLY) 12 V Input Current No load: 55, full load: 450 No load: 45, full load: 200 mA Input Voltage 15 (600 V to 1.5 kV ONLY) 24 V Input Current No load: 40, full load: 190 No load: 35, full load: 160 mA Polarity Fixed positive or fixed negative Output Voltage 0 to 600 0 to 1000 0 to 1250 0 to 1500 VDC Input Voltage 12 15 24 12 15 24 12 15 24 12 15 24 VDC Output Power 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1 W Output Current 0.83 1.33 1.67 0.5 0.8 1 0.4 0.64 0.8 0.33 0.53 0.67 mA Output Voltage 0 to 2000 0 to 2500 0 to 3000 VDC Input Voltage 5 15 24 5 15 24 5 15 24 VDC Output Power 0.5 0.8 1 0.5 .0.8 1 0.5 .0.8 1 W Output Current 0.25 0.40 0.50 0.20 0.32 0.40 0.167 0.267 0.333 mA Parameter All Types Units HV Setting 10 to 100 K (potentiometer across Vref. and signal ground, wiper to adjust) - Load Voltage Regulation < 0.01% of full output voltage for no load to full load VDC Line Voltage Regulation < 0.01% of full output voltage over specified input voltage range VDC Residual Ripple < 0.01% at full load V pk to pk Temperature Coefficient 100 ppm/C for the max output voltage after starting and over temperature range 0 to 50C - Output Voltage 600 to 1500 V: +1 V/1 kV max or -1 V/-1 kV max according to model polarity output impedance = to 200 - Monitoring k 1% 2 to 3 kV (12 to 24 V input only): 0 to +5 V2% - 2 to 3 kV (5 V inputs): 0 to +2.5 V2% - Reference Voltage 12 to 24 V input only: 5 V 1%, TC: 100 ppm/C, max output current: 1 mA - 5 V inputs: 2.5 V 1%, TC: 100 ppm/C, max output current: 1 mA - Operating Temperature -10 to +65, full load, max Eout, case temp C Storage Temperature -40 to +70 C Safeguards Arc and short-circuit protection - Options Shielded flying lead for HV output (0.6 to 1.5 kV units only) - Enhanced Interface (-EI) Enable/disable (ON/OFF): 0 to +0.5 V enable, +2.4V to Vinput disable (default = disable) - Option (2 to 3 kV Only) Output current monitor (5 V input only): 0 to +2.5 V 2% - Output current monitor (12 to 24 V input): 0 to +5.0 V 2% - 2 advancedenergy.com