ULTRAVOLT A SERIES HIGH VOLTAGE BIASING SUPPLY The A Series consists of miniature, PCB-mount, high voltage, regulated DC-DC converters. Designed and built utilizing state-of-the-art power-conversion topology, these units feature surface-mount technology and encapsulation techniques that provide high reliability and performance. PRODUCT HIGHLIGHTS Eight models from 0 to 62 V through 0 to 6 kV 4, 20, or 30 W of output power Maximum Iout capability down to 0 V Wide input voltage range Available with Ripple Stripper filter (-F option) Indefinite output short-circuit protection Output current monitor Fixed-frequency, low-stored-energy design > 430,000 hour MTBF at 65C (149F) UL/cUL recognized component CE Mark (LVD and RoHS) TYPICAL APPLICATIONS Bias supplies Electrostatic detectors Mass spectrometers Photomultiplier tubes (PMTs) 2018 Advanced Energy Industries, Inc.ULTRAVOLT A SERIES ELECTRICAL SPECIFICATIONS Parameter Conditions Models Units Input 12 V Voltage Full Power +11 to 16 VDC Range Voltage Derated Power +9 to 32 VDC Range Range Current Standby / Disable < 30 mA Current No Load, Max Eout < 100 mA Current Max Load, Max ~ 400 mA Eout AC Ripple Nominal Input, < 80 mA p-p Current Full Load Output 1/16A 1/8A 1/4A 1/2A Voltage Nominal Input 0 to 62 0 to 125 0 to 250 0 to 500 VDC Range Nominal Input Voltage 12 24 24 12 24 24 12 24 24 12 24 24 VDC Power Nominal Input, Max 4 20 30 4 20 30 4 20 30 4 20 30 W Eout Current Iout Entire Output 64 320 480 32 160 240 16 80 120 8 40 60 mA Voltage Range Current Full Load 0.985 3.90 7.40 438.4 1860.5 2891.5 0.985 3.90 7.40 438.4 1860.5 2891.5 mA/V Monitor Scaling Voltage With -Y5 option 10:1 2% into 10 M 10:1 2% into 10 M - Monitor Scaling Ripple Full Load, Max 0.02 0.03 0.05 0.013 0.015 0.016 0.01 0.04 0.048 0.001 0.02 0.017 %V p-p Eout Ripple Full Load, Max 0.002 0.004 0.006 0.0048 0.0056 0.006 0.0052 0.0028 0.005 0.001 0.0138 0.0016 %V p-p with -F-M Eout, 300 pF Option* Bypass Cap Dynamic to Full Load, < 0.12 < 0.12 < 0.12 < 0.12 < 0.12 < 0.12 < 0.20 < 0.20 < 0.20 < 0.50 < 0.50 < 0.50 V pk Load Max Eout per 0.1 Regulation mA Line Nom. Input, Max < 0.01 % < 0.01 % VDC Regulation Eout, Full Power Static Load No Load to Full < 0.01% < 0.01% VDC Regulation Load, Max Eout Stability 30 Min. warmup, < 0.01%/< 0.02% < 0.01%/< 0.02% VDC per 8 hr/ Per Day Programming & Controls All Types Input Nominal Input + output models 1.1 M to GND, - output models 1.1 M to +5 Vref M Impedance Adjust Typical 10 to 100 K (Pot. across Vref. and signal GND, wiper to adjust) Resistance Potentiometer Values Adjust 0 to +5 for +Out, +5 +4.64 VDC for +output or +0.36 for -output = nominal Eout - Logic to 0 for - Out Output T=+25C + 5.00 VDC 2%, Zout = 464 1% - Voltage & Impedance Enable/Disable 0 to +0.5 disable, +2.4 to 32 enable (default = enable) VDC 2 advanced-energy.com