ULTRAVOLT V SERIES VERTICAL, MICRO-SIZED HIGH VOLTAGE BIASING SUPPLIES The vertical, micro-sized V series is the ideal solution for applications that require a bias voltage ranging from 3 0 to 3000 V and very small current, at only 13.8 cc (0.84 in ). 2 2 With a footprint under 2.54 cm (1 in ), these modules are perfect for applications with limited board space. PRODUCT HIGHLIGHTS 7 models from 0 to 600, 1000, 1250, 1500, 2000, 2500, or 3000 V 0.5, 0.8, or 1 W of output power Tight line/load regulation Arc and continuous short circuit protection Self-restoring output voltage Low cost, miniature, and lightweight Voltage monitoring Low ripple (0.01% peak t o peak) Optional flying lead f or high-voltage output UL/cUL recognized, IEC-60950-1, CE Mark (LVD and RoHS) TYPICAL APPLICATIONS Bias supplies Electrostatic chucks Hand held x-ray florescence (XRF) Avalanche photo diodes (APD) Photomultiplier tubes (PMT) Silicon detector (SiD) X-ray flat panel detector (FPD) Ionization chamber detector 2019 Advanced Energy Industries, Inc.ULTRAVOLT V SERIES ELECTRICAL SPECIFICATIONS Parameter Specifications Units Input Voltage Vin 5 0.5 (2 to 3 kV only) 12 1, 15 1 (600 V to 1.5 kV only), or 24 2 VDC (Pins 1 and 2) Input Voltage 5 (2 to 3 kV only) 12 15 (600 V to 1.5 kV only) 24 V Input Current No load: 55, full load: 450 No load: 45, full load: 200 No load: 40, full load: 190 No load: 35, full load: 160 mA Polarity Fixed positive and fixed negative - Output Voltage 0 to 600 0 to 1000 0 to 1250 0 to 1500 VDC Input Voltage 12 15 24 12 15 24 12 15 24 12 15 24 VDC Output Power 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1 W Output Current 0.83 1.33 1.67 0.5 0.8 1 0.4 0.64 0.8 0.33 0.53 0.67 mA Output Voltage 0 to 2000 0 to 2500 0 to 3000 VDC Input Voltage 5 12 24 5 12 24 5 12 24 VDC Output Power 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1 W Output Current 0.25 0.40 0.50 0.20 0.32 0.40 0.167 0.267 0.333 mA HV Setting 10 to 100K (potentiometer across vRef. and signal ground, wiper to adjust) - Load Voltage < 0.01% of full output voltage for no load to full load VDC Regulation Line Voltage Regulation < 0.01% of full output voltage over specified input voltage range VDC Residual Ripple < 0.01% at full load V pk to pk Temperature 100 ppm/C for the max output voltage after starting and over temperature range 0 to 50C - Coefficient Output Voltage Monitor +1 V/1 kV max or -1 V/-1 kV max according to model polarity output impedance = 200 k 1% - (600 to 1500 V) Output Voltage Monitor 12 to 24 V input only: 0 to +5 V 2% - (2 to 3 kV) 5 V inputs: 0 to +2.5 V 2% - Reference Voltage 12 to 24 V input only: 5 V 1%, TC: 100 ppm/C, max output current: 1 mA - 5 V inputs: 2.5 V 1%, TC: 100 ppm/C, max output current: 1 mA - Operating Temperature -10 to +65, full load, max Eout, case temp. C Storage Temperature -20 to +70 C Safeguards Arc and short circuit protection - Options Flying lead for HV output - Enhanced Interface Enable/disable (ON/OFF): 0 V to +0.5 V enable, +2.4 V to V input disable (default = disable) - (-EI) Option Output current monitor (5 V input only): 0 to +2.5 V 2% - (2 to 3 kV Only) Output current monitor (12 to 24 V input): 0 to +5.0 V 2% - 2 advancedenergy.com