ULTRAVOLT MPM 100 TO 500 SERIES COMPACT DC TO HIGH VOLTAGE DC CONVERTERS The UltraVolt MPM series of proportional DC-to-DC converters provide compact, general purpose high voltage power. PRODUCT HIGHLIGHTS Unregulated proportional control outputs ranging from 100 to 500 VDC maximum AT A GLANCE Single output: positive and negative polarity models 1.5 W maximum output power 12 or 24 VDC input Maximum Output Voltage Output ripple performance < 0.5% (to < 0.05% with optional shield) 100, 200, 300, or 500 VDC Temperature coefficient < 300 ppm/C Maximum Output Power PCB-mount Reversed polarity and intermittent short-circuit protection 1.5 W Optional 100 VDC isolation between input and high voltage output Type Available shielded case to guard against external radiated emissions Single Output CE mark (LVD and RoHS) Ripple TYPICAL APPLICATIONS < 0.5% DC to high voltage DC bias supplies for general purpose uses Control Interface Ink-jet printers and electrostatic separators Proportional Rail supplies for PMT/APD detectors and Geiger-Muller tubes Temperature Coefficient Electron-beam deflectors and focusing optics < 300 ppm/C 2018 Advanced Energy Industries, Inc.ULTRAVOLT MPM 100 TO 500 SERIES ELECTRICAL SPECIFICATIONS Model 1 100 Series 200 Series High Voltage Output Range (Proportional, Positive or Negative) 17 to 100 VDC 34 to 200 VDC High Voltage Outputs Single Single Input Voltage (VDC, Nominal) 12 VDC 24 VDC 12 VDC 24 VDC Power Output (Watts, Nominal) 1.5 W 1.5 W DC Input Vin (Input Voltage) Range VDC (positive polarity only) 0 to 12 0 to 24 0 to 12 0 to 24 Vin (Nominal) VDC 2 to 12 4 to 24 2 to 12 4 to 24 lin (Input Current, Nominal) A 100% HVout, 100% LOAD < 0.25 < 0.13 < 0.25 < 0.13 A 100% HVout, 0% LOAD < 0.04 < 0.04 DC Output HVout (Output Voltage) VDC (positive polarity models = +HVout) +17 to +100 +17 to +100 +34 to +200 +34 to +200 VDC (negative polarity models = -HVout) -17 to -100 -17 to -100 -34 to -200 -34 to -200 Iout (Output Current) mA (max) 0 to 100% HVout, Vin (nominal) 15 7.5 Pout (Output Power) Watts (max) 1.5 1.5 , Ripple 2 3 % (% with S option) < 0.5% (< 0.25%) < 0.5% (< 0.05%) ppm (ppm with S option) < 5000 (< 2500) < 5000 (< 500) Vpp (Vpp with S option) < 0.5 (< 0.25) < 1 (< 0.1) Model 1 300 Series 500 Series High Voltage Output Range (Proportional, Positive or Negative) 50 to 300 VDC 84 to 500 VDC High Voltage Outputs Single Single Input Voltage (VDC, Nominal) 12 VDC 24 VDC 12 VDC 24 VDC Power Output (Watts, Nominal) 1.5 W 1.5 W DC Input Vin (Input Voltage) Range VDC (positive polarity only) 0 to 12 0 to 24 0 to 12 0 to 24 Vin (Nominal) VDC 2 to 12 4 to 24 2 to 12 4 to 24 lin (Input Current, Nominal) A 100% HVout, 100% LOAD < 0.25 < 0.13 < 0.25 < 0 .13 A 100% HVout, 0% LOAD < 0.04 < 0.04 DC Output HVout (Output Voltage) VDC (positive polarity models = +HVout) +50 to +300 +50 to +300 +84 to +500 +84 to +500 VDC (negative polarity models = -HVout) -50 to -300 -50 to -300 -84 to -500 -84 to -500 Iout (Output Current) mA (max) 0 to 100% HVout, Vin (nominal) 5 3 Pout (Output Power) Watts (max) 1.5 1.5 , Ripple 2 3 % (% with S option) < 0.5% (< 0.05%) < 0.5% (< 0.05%) ppm (ppm with S option) < 5000 (< 500) < 5000 (< 500) Vpp (Vpp with S option) < 1.5 (< 0.15) < 2.5 (< 0.25) 1 Standard product specifications shown unless noted. For 1000 to 3000 VDC HVout ranges, see MPM 1K to 3K series datasheet. 2 Nominal ripple measured 100% HVout, 100% LOAD into 300 pf bypass capacitor. 3 % = percent 100% HVout ppm = parts per million 100% HVout Vpp = VDC peak to peak 100% HVout. 2 advanced-energy.com