THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS AT A GLANCE The Thyro-PX series are modular, easy-to-use premier performance SCR power controllers for heating elements, resistive loads and transformer loads, in Phase Type heating, melting, drying, and forming applications. 1, 2, and 3-phase power controller Accuracy PRODUCT HIGHLIGHTS 0.5% voltage or current Comprehensive operating and control modes to minimize 1% power harmonic distortion and utility costs AC Input Line Voltage Rating High-efficiency, wear-free design with integrated soft starting for usage with downstream transformers 230 to 500 V -20 to +10% 690 V -20 to +10% Premier performance control accuracy to maximize end-process repeatability Multi-zone capability that independently controls multiple Type Current Range single-phase loads from a single controller 16 to 2900 A Wide communication protocol flexibility for simple integration into Rockwell PAC via certified AOP Control Modes Wide performance range with rated currents up to 2900 A Zero cross firing (TAKT) and rated voltages up to 690 V Phase-angle firing (VAR) I ntuitive performance and status feedback via a modular, Voltage sequence control (VSC) integrated touch screen display or PC tool Soft start, soft down Communications TYPICAL APPLICATIONS Ethernet/IP, EtherCAT Transformer loads, resistive loads, and heating elements in electric furnaces PROFIBUS, PROFINET used for glass, metals, and ceramics manufacture Modbus RTU, Modbus TCP/IP Heat tracing for piping and process elements in chemical, DeviceNET petro-chemical, and oil processing Extruder and plastic press heating, IR drying, and automotive applications 2018 Advanced Energy Industries, Inc.THYRO-PX SERIES PRODUCT SPECIFICATIONS THYRO-PX Model Thyro-PX 1PX Thyro-PX 2PX Thyro-PX 3PX One-phase power controller Two-phase power controller for three-phase economic circuit Three-phase power controller Full wave switch (TAKT) Full wave switch (TAKT) Full wave switch (TAKT) Phase-angle firing (VAR) Phase-angle firing (VAR) THYRO-PX Series Control Accuracy 0.5% voltage or current, 1% power Load Types Resistive loads, transformer loads, and loads with large Rwarm/Rcold up to factor 20 (MOSI starting mode) Operating Modes TAKT: full frequency package control VAR: phase-angle firing VSC VAR: voltage sequence control with phase-angle firing 2 2 Control Types U-voltage, U -voltage, I-current, I -current, P-power, without regulation Set Point Input Up to 3 analog inputs (freely configurable), control start/finish can be set as desired between 0 (4) to 20 mA 0 (1) to 10 (2)V. Actual Value Outputs 3 measuring values for optional display of U, I, and P can be set as desired between 0 to 20 mA 0 to 10 V Load Circuit/Self-Monitoring Provided Operation/Fault Indicators Via 3 fault signaling relays and status/diagnostic LEDs, freely configurable Fuse Integrated semiconductor fuse ELECTRICAL SPECIFICATIONS Rated Connection Voltage 500 V type: 230 V -20% up to 500 V +10% 690 V type: 500 V -20% up to 690 V +10% Frequency All types, 45 to 65 Hz Control Voltage AC min 90 to max 265 V alternative DC 24 V (10%) Ventilator (HF Types Only) 230 V, 50 to 60 Hz optional 115 VAC, 50 to 60 Hz Environmental Ambient Temperature Up to 35C (95F) by external fan cooling (for HF types, with integrated fan) with rated current Up to 45C (113F) by passive convection cooling with rated current At higher temperatures, operation is permissible with reduced current limits. Max 40C (104F) for UL applications Storage Temperature -25 to +55C (-13 to 131F) Humidity Class DIN EN 50178 Tab. 7 Site Altitude Up to 1000 m (3281 ft) above sea level at nominal load above 1000 m (3281 ft), on request Regulatory Certifications CE marked for EU LV Directive 2014/35/EU and 2004/108/EC UL Certified, UL 508A (100 kVA short circuit test) 2 advanced-energy.com