Special POWER QUALITY ANALGRYZERS, METERS & LOUND RESISTANCE TESOGGERSTER DATA LDOGGERSATA LOGGERS product features Simple LoggerSimple Logger II TRMS Current II TRMS Current Three-Phase Power Quality Multi-FunctionAnalyzer Models L101, L102 & L111 One channel loggers with the ability to perform a variety of recording tasks FEATURES Compatible standard current probes with voltage output and BNC connection (Models L101 & L102) (sold separately) Fused input (Model L111) Compatible with standard AC current probes with current output and banana plug connection (Model L111) 2 inputs (Model L102) 64 samples per cycle Programmable storage rates from 8 every second to 1 every day IP 4 user selectable storage modes 40 Rated SPECIFICATIONS Stores up to 240,000 measurements in non-volatile memory MODELS L101 L102 L111 ELECTRICAL Powered by standard Alkaline batteries Channels One Two One Lightweight, compact, fits anywhere Input Connection BNC One BNC Two recessed banana jacks 5 LED indicators quickly and clearly connector per channel display logger status Measurement Range 0 to 1Vac (probe dependent) 0 to 1Aac (probe dependent) Includes FREE DataView software for data storage, Resolution 0.1mV 0.1mA real-time display, analysis and report generation Accuracy 0 to 10mV: unspecified 0 to 10mA: unspecified (50/60Hz) 10 to 50mV: 10 to 50mA: Optically isolated USB 2.0 communication (0.5% of Reading + 1mV) (0.5% of Reading + 1mA) cable included 50 to 1000mV: 50 to 1000mA: (0.5% of Reading + 0.5mV) (0.5% of Reading + 0.5mA) EN 61010-1 50V CAT III Input Impedance 800k 1 Sample Rate 64 samples/cycle APPLICATIONS ( MODELS L101 & L111) Storage Rate Programmable from 8 every second to 1 every day Load profiling Storage Modes Start/Stop, FIFO, Extended Recording Mode (XRM ) and Alarm Fault current detection Recording Length 15 minutes to 8 weeks, programmable using DataView Intermittent problem detection Memory 240,000 measurements (512KB) The recorded data is stored in non-volatile memory and will be Demand recording retained even if the battery is low or removed. Neutral current monitoring Communication USB 2.0 optically isolated Harmonic current recording using DataView software Power Source 2 x 1.5V AA-cell Alkaline batteries (included) Battery Life 100 hours to >45 days Metering CT resizing (dependent on sample rate and recording length) Start-Stop time stamping MECHANICAL Dimensions 5.18 x 2.75 x 1.28 5.38 x 2.75 x 1.28 APPLICATIONS ( MODEL L102) (132 x 70 x 32mm) (136 x 70 x 32mm) Split phase load monitoring Max Conductor Size Current probe dependent Neutral & ground current monitoring Weight (with battery) 6.4 oz (181g) 6.64 oz (188g) Intermittent problem detection Case UL94-V0 Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz) Harmonic current monitoring using DataView software Shock IEC 68-2-27 (30G) Machine load monitoring Drop IEC 68-2-32 (1m) Start-Stop time stamping Current probe selection chart on following pages CATALOG NO. DESCRIPTION 2126.02 Simple Logger II Model L101 (1-Channel, TRMS, 0 to 1Vca , DataView software) 2126.03 Simple Logger II Model L102 (2-Channel, TRMS, 0 to 1Vca , DataView software) 2126.04 Simple Logger II Model L111 (1-Channel, TRMS, 0 to 1Aca , DataView software) Technical Assistance (800) 343-1391 www.aemc.comDATA LOGGERS Probe Selection Chart AEMC AEMC USED WITH PROBE PROBE MAX RANGE CABLE BUS BAR OUTPUT MODEL CATALOG LOGGER NOTES OUTPUT RANGE FOR SLII DIAMETER SIZE CONNECTION NUMBER NUMBER MODEL L101 100mV/Aac 0.1 to 24Aac 10Aac MN261 2115.82 0.78 N/A Lead w/BNC L102 10mV/Aac 0.5 to 240Aac 100Aac L562 JM830A 2110.83 0.333mA/Aac 1 to 2400A 2400a 2.52 1.97 x 5.31 Lead L111 10mV/Aac 1 to 30Aac 30Aac L101 JM861 2110.90 1mV/Aac 1 to 300Aac 300Aac 2.52 1.97 x 5.31 Lead w/BNC L102 0.1mV/Aac 1 to 3000Aac 3000Aac L562 L101 100mV/Aac 30Aac 10Aac MF 300-6-2-10 2126.81 1.77 2.25 x 3/4 Sensor w/BNC L102 10mV/Aac 300Aac 100Aac L562 L101 100mV/Aac 5 to 30A 10A Sensor Must use adapter 300-24-2-1 2112.88 8 N/A L102 10mV/Aac 5 to 300A 100A w/Banana Plugs 2118.46 L562 L101 Sensor Must use adapter 1000-24-1-1 2112.39 1mV/Aac 5 to 1000A 1000A 8 N/A L102 w/Banana Plugs 2118.46 L562 L101 10mVac 5 to 100A 100A Sensor Must use adapter 1000-24-2-1 2112.98 8 N/A L102 1mV/Aac 5 to 1000A 1000A w/Banana Plugs 2118.46 L562 L101 10mVac 5 to 100A 100A Sensor Must use adapter 1000-36-2-1 2113.00 11 N/A L102 1mV/Aac 5 to 1000A 1000A w/Banana Plugs 2118.46 L562 L101 3.3mV/Aac 5 to 300A 300A Sensor Must use adapter 3000-24-2-0.3 2114.87 8 N/A L102 0.3mV/Aac 5 to 3000A 3000A w/Banana Plugs 2118.46 L562 L101 1mV/Aac 5 to 600A 600A Sensor Must use adapter 6000-36-2-0.1 2113.21 11 N/A L102 0.1mV/Aac 5 to 6000A 6000A w/Banana Plugs 2118.46 L562 L101 1mV/Aac 5 to 3000A 1000A Sensor Must use adapter 30000-24-2-0.1 2113.33 8 N/A L102 0.1mV/Aac 5 to 30,000A 10000A w/Banana Plugs 2118.46 L562 MN01 2129.17 1mA/Aac 2 to 150A 150A 0.39 N/A Lead L111 50mA to 100A (1) MN02 2129.20 1mA/Aac 100Aac 0.39 N/A Lead L111 50mA to 90A (10) L101 Lead Must use adapter MN03 2129.18 1mV/Aac 2 to 100Aac 100Aac 0.47 N/A L102 w/Banana Plug 2118.46 L562 L104 MN93-BK 2140.32 5mV/Aac 2 to 240Aac 200Aac 0.8 N/A Proprietary L564 200mV/Aac 5A L104 MN193-BK 2140.36 5 to 100Aac 0.8 N/A Proprietary 10mV/Aac 100A L564 L101 Lead Must use adapter MN251 2115.77 1mV/Aac 0.5 to 240A 240Aac 0.78 N/A L102 w/Banana Plug 2118.46 L562 L101 100mV/Aac 0.1 to 24Aac 10Aac Lead Must use adapter MN255 2115.81 0.78 N/A L102 10mV/Aac 0.1 to 240Aac 100Aac w/Banana Plug 2118.46 L562 www.aemc.com Technical Assistance (800) 343-1391