AC Current Probe Model MN373 The Model MN373 is the latest in Features Applications compact AC current probes. It is Small, compact size Measur ing in breaker panels designed to meet the most stringent demands in industry and electrical Measurement range of Industrial loads contracting. Model MN373 meets 0.01 to 150A HVAC EN 61010, 600V, Cat. III safety Large jaw opening accommodates standards and is CE Marked and Residential and commercial sites conductors up to 250MCM UL approved for Canada and 5A secondary current tr ansformers United States. Designed for DMMs, loggers, (CTs) monitoring recorders and oscilloscopes The Model MN373 has a 0.78 (20mm) Data logging/recording jaw opening and accommodate 40Hz to 10kHz response conductors up to 250MCM. The 1000mV/A ca 10mV/Aca unique hooked jaw design facilitates output signals clamping and hooking onto Designed to EN 61010, 600V, conductors. Polycarbonate materials Cat. III safety standard and ultrasonic welding are used throughout to ensure ruggedness UL approved for Canada and and overall lasting reliability. United States The Model MN373 is a high Doub le Insulation performance model and uses a CE Mark custom nickel core to improve a ccuracy and phase shift on the low end of the measurement range. The Model MN373 is an excellent probe to be used in power and low level current measurement applications. MN373 211628 (pdf) 0408 Rev.04 Technical Assistance (800) 343-1391 www.aemc.com 1 of 4Specifications Model MN373 ElEctrical Nominal range 2A & 150A Measurement range 0.1 to 150A transformation ratio Voltage output Output Signal 2A: 1000mV/A 150A: 10mV/A accuracy (2A Range) 0.01 to 0.1A 5% of Reading 2mV 0.1 to 1A 3% of Reading 1mV 1 to 2.4A 1% of Reading Phase Shift (2A Range) Not Specified Overload (2A Range) 2.4A for 10 min ON & 30 min OFF accuracy (150A Range) 0.1 to 1A 3% of Reading 200V 1 to 20A 2% of Reading 200V 20 to 80A 1% of Reading 80 to 150A 3% of Reading 150 to 200A Not Specified Phase Shift (150A Range) 0.1 to 1A Not Specified 1 to 20A 3 20 to 80A 2 80 to 150A 3 150 to 200A 4 Overload 240A for 10 min ON, 30 min OFF Frequency range 40 to 10kHz limit Operating 200A permanently to 1kHz Derating above 3kHz: 200A x (1/0.333F), F in kHz to 1kHz crest Factor 2A: 3 2A Peak with an error (due to CF) of 3% 150A: 3 150A Peak with an error (due to CF) of 3% Working/common 600Vrms Mode Voltage Output termination 5 ft Lead MEchaNical Operating temperature 14 to 131F (-10 to 55C) Storage temperature -40 to 158F (-40 to 70C) Operating relative 10 to 35C 85% RH (without roll-off above 35C) humidity Jaw Opening 0.83 (21mm) Maximum conductor Size 0.78 (20mm) Dimensions 5.47 x 2.00 x 1.18 (139 x 51 x 30mm) Weight 6.5 oz (180g) Polycarbonate Material Polycarbonate with fiberglass charge, UL94 V0 SaFEty Electrical EN 61010-2-32 Ul approval Yes Canada and United States Double insulation Yes cE Mark Yes Note: Ref erence conditions: 20 to 26C, 20 to 75% RH, external magnetic field <40A/m, 48 to 65Hz sine wave, distortion factor less than 1%, no DC component, no external current carrying conductor, test sample centered. Load impedance >1m MN373 211628 (pdf) 0408 Rev.04 Technical Assistance (800) 343-1391 www.aemc.com 2 of 4