Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. 6416 Construction Diameters (In) 1) Component 1 2 X 1 PAIR a) Conductor 20 (7/28) AWG Tinned Copper 0.038 b) Insulation 0.010 Wall, Nom. PVC, Semi Rigid 0.058 (1) Color(s) Pair Color Pair Color Pair Color 1 BLACK-RED 2 GREEN-WHITE c) Pair 2/Cond Cabled Together (1) Twists: 8.0 Twists/foot (min) Individually Applied: Foil Free Alum/Mylar Tape, 25% d) Shield: Overlap, Min. (1) Foil Direction Foil Facing In (2) Drain Wire 22 (7/30) AWG Tinned Copper 2) Cable Assembly 2 Components Cabled a) Twists: 4.0 Twists/foot (min) Components to be arranged from b) Orientation: INSIDE LAYER to OUTSIDE LAYER 3) Jacket 0.041 Wall, Nom.,PVC 0.295 (0.309 Max.) a) Color(s) SLATE ALPHA WIRE-* P/N 6416 2PR 20 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2464 OR C(UL) 75C TYPE CMG FT4 CE ROHS b) Print * = Factory Code Note: Product may have c(UL) or CSA markings depending upon plant of manufacture. Applicable Specifications 80C / 300 V 1) UL AWM/STYLE 2464 RMS CM 75C VW-1 2) CSA International CMG 75C FT4 3) CE: EU Low Voltage Directive 2014/35/EU Environmental 1) CE: EU Directive 2011/65/EU(RoHS2): This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire s web site for RoHS C of C. 2) REACH Regulation (EC 1907/2006): This product does not contain Substances of Very High Concern (SVHC) listed on the European Union s REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha s REACH SVHC Declaration. Exempt from warning labels based on the Consent Judgment. Please see 3) California Proposition 65: Alpha s CA Prop 65 Statement for more information. Properties Physical & Mechanical Properties 1) Temperature Range -20 to 80C 2) Bend Radius 10X Cable Diameter 3) Pull Tension 46 Lbs, Maximum Electrical Properties (For Engineering purposes only) 300 V 1) Voltage Rating RMS 2) Mutual Capacitance 55 pF/ft 1 kHz, Nominal 3) Ground Capacitance 95 pF/ft 1 kHz, Nominal 4) Conductor DCR 10.3 /1000ft 20C, Nominal 5) Ind. Shield DC Resistance 13.9 /1000ft 20C, Nominal