Customer: N o. SH065052A Date: 2006- 07- 20 ALPS EUROPE DISTRIBDTION Attention: Your ref.No. : Your Part No. : SSSS922500 SPECIF I CATION ALPS STSSS9221 MODEL: S p e c. N o. : SSSS9-S-501 Sample No. : P3291177H RECEIPT STATUS RECEIVED By Date S ignature Name Title ALPS. ALPS ELECTRIC CO., LTD. Head Office 1-7,Yukigaya-otsuka-cho,Ota-ku,Tokyo.145-8501 Japan Phone.+81(3)3726-1211 (SL) PAGE P3CUHENT No. TITIS PRODUCT SPECIFICATIONS 1/5 SSS59-S-501 Ht iS. -fcfc S =QF BACKGEOTOD 1. General 1.1 Application fflHIEffl This specification is applied to low current circuit (Secondary circuit) slide switcb used for electronic equiptent. CDli&SfctSEfc TfByWiBCfflUSffitCtSlElHifl (2ttfflElSS I) X94 Y3.-f yf-UJSKlti, 1.2 Operating terpcraturo range ffifflSU&ISBB: -40 ~ 85*C 1.3 Storage teaperature range KfffflffiKffl: -40 - WC l. Toot conditions && & Unless otherwise specified, ths atBospheric conditions for Baking oeasurenents and tests are as follows. Anbient tenperature ffl S: 5~35*C Relative huaidity : 45~90X Air pressure p ffi: 86~106kPa Should any doubt arise in judgetent, tests shall be conducted at the following coalitions. Aibient teiperaturc 81 & : 202*C Relative huaidity *f: 60-70SS Air pressure ft &: 8S~10SkPa 2.Appearance, construction and dieensions JMBL Switch shall nave good finishing, and no rust, crack or plating failures. 2.1 Appearance ftR asottiifttJiff-c, tt6B-t*rsa. a. ein, m 2.2 Construction end dieensians WiE> fffi Eefer to individual product drawing. S.Eating ffite Haxisani rating fcfc i2 V DC 0.1 A (Eesistive load)(Sttfla) 12 V DC 0.6 A (Eesistive loadXttttflW) Hinimia rating JS 1 V DC lOaA (Eesistive loid)(ttfl ) 4. Electrical spscification Criteria Test conditions a tt Item W B 30 aQ Htt Shall bo aeasured at 1 WIi+200 Hi (20 aV XU, SO iA HU) or 1 A, 5 V DC by 4.1 Contact resistance iftttffift voltaso drop Mtbod. 1 kH:200 Kz. ffi 20 aV UT. 50 M dc sv, u 100 MO HIK 4.2 Insulation Test voltage: SOD V DC, teasured after 1 tin 5 s resistance Applied position Between all terainals Between teninals and grouad(frsBe) DC 809 V Test voltage : 500 V AC (50~KHt, cut-off current 2 tA) No dielectric breakdown shall occur. 4.3 Voltage proof ISE Duration: 1 zin Applied position: Between all teninals Between terainals and grounii(fran) AC 500 V (50~60Hi, &&&& 2 A) Ottffifc lffl Sffl. Rita 15. 4.4 Changeover tining Safer to individual product drawing. S. Hechaoical specification Criteria Teat conditions K ff S Refer to individual product drawing. A static load shall be applied to ths root of actuator in opsroting direction. 5.1 Operating force ft ffi A 5.2 Eobustsess of A static load of 3 H i=89IHift shall bo applied to the tip of terminal in a Shall be free froa tcrsinal looseness, daiage and breakage of terninal holding tcnrinal desired direction for 1 ain. The test shall be done once per tertisal. portion. Tcrainals lay be bent after test. 3 h /J Electrical porfomance rcwiraent speci fied in itea 4 shall be satisfied. otts. tit. meat s-rsct. CSOD. CHXD. AP Dr97 H.K H. , H.K JnneS93 H.K S.T X. EL. Kamada APfO CHKD STMB DATE FAGS DATE PAGE BACKCEOffllD APPD CHKD ALPS ELECTeiCCO.,LTD.