E-TRIP ONE POLE ONE POLE PLUS NEUTRAL CHARACTERISTICS Application Examples: High efficiency motors, which have exceedingly high inrush currents. Relatively short thermal trip delays and very high magnetic trip points. Prototype testing is recommended. The V-EA-E is the result of continuous research and improvement of our G- and D-Trip circuit breakers. It combines the short thermal trip delay 1E 2EN of the G-Trip and an even higher magnetic trip point than the D-Trip. Rated Type/ Type/ Therefore, the V-EA-E provides Current Cat. No. Approvals Cat. No. Approvals adequate motor overload and short 0.3A 1EU03 U U L 2ENU03 L circuit protection. U U 0.5A 1EU05 L 2ENU05 L 0.75A 1EU075 U U L 2ENU075 L Type Designation 0.8A NA NA 1.0A 1EU1 U U L 2ENU1 L 2E N U 60 U U 1.6A 1EU1.6 L L 2ENU1.6 2.0A 1EU2 U U L 2ENU2 L (a) (b) (c) (d) (e) 2.5A 1EU2.5 U U L 2ENU2.5 L U U 3.0A 1EU3 L 2ENU3 L (a) = Number of Poles U U 3.5A 1EU3.5 L 2ENU3.5 L (b) = Trip Characteristic U U L L 4.0A 1EU4 2ENU4 (c) = Blank: without neutral pole U U L L 5.0A 1EU5 2ENU5 U U = N: with neutral pole L L 6.0A 1EU6 2ENU6 U U L 2ENU8 L 8.0A 1EU8 (d) = U: UL/CSA version U U L 2ENU10 L 10A 1EU10 = R: ring tongue terminals, U U L 2ENU12 L 12A 1EU12 UL/CSA version U U L 2ENU125 L 12.5A 1EU125 U U = Blank: European version L L 2ENU13 13A 1EU13 U U L 2ENU15 L 15A 1EU15 (e) = Rated Current U U L 2ENU16 L 16A 1EU16 U U L L 20A 1EU20 2ENU20 U U L 2ENU25 L 25A 1EU25 U U 30A 1EU30 L 2ENU30 L Approvals: U U L 2ENU32 L 32A 1EU32 U U 40A 1EU40 L 2ENU40 L U U L L 50A 1EU50 2ENU50 UL508 Listed U U 60A 1EU60 L 2ENU60 L 63A 1EU63 2ENU63 277VAC 277VAC Voltage Rating 0.3-60A (RC): 10kA with UL-listed 0.3-60A (RC): 10kA with UL-listed Interrupting Capacity RK5 back-up fuse or MCCB RK5 back-up fuse or MCCB (UL/CSA - Ratings) 0.3-10A (RC): 10kA 12-60A (RC): 5kA 0.3-10A (RC): 10kA 12-60A (RC): 5kA Group Short Circuit no branch circuit protection required no branch circuit protection required (UL/CSA - Ratings) 0.3-63A (RC): 10kA 0.3-63A (RC): 10kA Interrupting Capacity (VDE - Ratings) 10000 ON/OFF operations 10000 ON/OFF operations Mechanical Endurance 40C (104F) 40C (104F) Calibration Temperature 10/0.3A - 32A = 1.4kg (3.1 lb.) 5/0.3A - 32A = 1.3kg (2.9 lb.) Standard Pack and Weight 40A - 63A = 1.6kg (3.5 lb.) 40A - 63A = 1.45kg (3.2 lb.) Top: 18-3 AWG Bottom: 18-2 AWG Top: 18-3 AWG Bottom: 18-2 AWG Terminal Size Acceptability 20 lb.in. 20 lb.in. Terminal Torque Basic Dimensions (Elevation View) Not European standard rating. 91.5 mm 91.5 mm (3.60 in.) (3.60 in.) Please refer to page 21 for specific applications. DC rating (Manufacturers self certification): One pole 48VDC, two pole series 125VDC 17.5 mm (0.69 in.) 35 mm (1.38 in.) Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com 14TWO POLE THREE POLE Basic Dimensions (side view) 35 mm (1.38 in.) 70mm (2.76 in.) 2E 3E V-EA-E Trip Rated Type/ Type/ 0.3A Through 10A Rated Current Current Cat. No. Approvals Cat. No. Approvals 1.05-1.35xI N 60 40 U U 0.3A 2EU03 L 3EU03 L 10 U U 0.5A 2EU05 L 3EU05 L Thermal Overload 4 Must Trip < 1 hr = 135% RC U U 0.75A 2EU075 L 3EU075 L Must Not Trip > 1 hr = 105% RC 0.8A NA NA 1 U U 1.0A 2EU1 L 3EU1 L 10 U U L L 1.6A 2EU1.6 3EU1.6 4 U U 2.0A 2EU2 L 3EU2 L U U 2.5A 2EU2.5 L 3EU2.5 L 1 U U 3.0A 2EU3 L 3EU3 L 0.4 U U 3.5A 2EU3.5 L 3EU3.5 L -1 10 U U L L 4.0A 2EU4 3EU4 -2 4x10 U U L L 5.0A 2EU5 3EU5 -2 U U 10 L L 6.0A 2EU6 3EU6 -3 4x10 U U 8.0A 2EU8 L 3EU8 L U U 10A 2EU10 L 3EU10 L -3 10 123456810 141820 40 100 U U L L 12A 2EU12 3EU12 Multiple of Rated Current U U L L 12.5A 2EU125 3EU125 E0.3A-E10A U U L L 13A 2EU13 3EU13 V-EA-E Trip U U L L 15A 2EU15 3EU15 12A Through 60A Rated Current U U L L 16A 2EU16 3EU16 1.05-1.35xI N 60 U U L L 40 20A 2EU20 3EU20 U U 25A 2EU25 L 3EU25 L 10 U U L L 30A 2EU30 3EU30 Thermal Overload 4 Must Trip < 1 hr = 135% RC U U 32A 2EU32 L 3EU32 L Must Not Trip > 1 hr = 105% RC 1 U U 40A 2EU40 L 3EU40 L U U L L 50A 2EU50 3EU50 10 U U L L 60A 2EU60 3EU60 4 63A 2EU63 3EU63 1 480Y/277VAC 480Y/277VAC 0.4 0.3-60A (RC): 10kA with UL-listed 0.3-60A (RC): 10kA with UL-listed -1 10 RK5 back-up fuse or MCCB RK5 back-up fuse or MCCB -2 4x10 0.3-10A (RC): 10kA 12-60A (RC): 5kA 0.3-10A (RC): 10kA 12-60A (RC): 5kA -2 10 no branch circuit protection required no branch circuit protection required -3 4x10 0.3-63A (RC): 10kA 0.3-63A (RC): 10kA -3 10 1234568 10 14 18 20 40 100 10000 ON/OFF operations 10000 ON/OFF operations Multiple of Rated Current 40C (104F) 40C (104F) E Magnetic Trip Parameters Rated Current, 0.3A to 50A ( ), 5/1.4kg (3.1 lb.) 4/1.68kg (3.7 lb.) 60/63A (- - - - -). Top: 18-3 AWG Bottom: 18-2 AWG Top: 18-3 AWG Bottom: 18-2 AWG Magnetic Trip: 1. Hold for a minimum of 100ms at 20 lb.in. 20 lb.in. surge of 14 times (60A, 10 times) rated current. 2. Trip in under 100ms at 18 times (60A, 14 times) rated current. 91.5 mm 91.5 mm (3.60 in.) (3.60 in.) NB: Trip curves shown comply with North American standards. For trip curves according to European standards please consult Altech. 35 mm (1.38 in.) 52.5 mm (2.07 in.) Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com 15 Tripping time t Tripping time t Seconds Minutes Seconds Minutes