CircuitProtection 2016.QXD CircuitProtection 4/4/16 12:25 PM Page 86 RP - Series RCCB Earth Leakage Circuit Breakers RCCB Series compact Earth Leakage Circuit Break ers de tect and in ter rupt earth (ground) faults. They are VDE approved for the Eu - ro pe an system of pro tecti ng peo - ple, animals, equipment and prop - er ty from dangero us line-to-ground RP2 RP4 and shock haz ard cur rents. Maximum US applications include ground- Rated Fault Fault fault prot ec tion of equip ment Line Trip Trip (GFPE) using the 10mA and 30mA Current Current Cat. No. Current Cat. No. fault current rat ings, es pe ciall y 16A 10mA RP2101 when high distributed ca pac i tance or other leakag es cause exc ess ive 25A 30mA RP2203 30mA RP4203 25A 300mA RP2230 300mA RP4230 nuis ance trips at lower fault cur- 25A 500mA RP4250 rents. Applications for the 300mA and 500mA ratings are equipm ent 40A 30mA RP2303 30mA RP4303 protection and fire preven tion, lim - 40A 300mA RP2330 300mA RP4330 it ing the energy of a fault to less 40A 500mA RP4350 than the minimum ignition en er gy 63A 30mA RP2403 30mA RP4403 for many materials. 63A 300mA RP2430 300mA RP4430 Type Designation 63A 500mA RP2450 500mA RP4450 80A 30mA RP4503 RP (a) (b) (c) 80A 300mA RP4530 80A 500mA RP4550 (a) = 2-2 pole 4-4 pole 100A 30mA RP4603 (b) = 1-16A 2-25A 3-40A 4-63A 100A 300mA RP4630 5-80A 6-100A 7-125A 100A 500mA RP4650 (c) = 01 - 10mA 125A 30mA RP4703 = 03 - 30mA 125A 300mA RP4730 = 30 - 300mA 125A 500mA RP4750 = 50 - 500mA Stock items are shown in BOLD. Voltage Rating (maximum) 230V AC, 50Hz 400Y/230V AC, 50Hz Short Circuit Withstand Rating No back-up fuse: Rated current (RC) 16/25/40A: 500A RC 63/80A: 800A RC 100A: 1000A RC 125A- 1250A. With back-up fuse: 10kA Size of fuse: (2 pole version): RC 25/40/63: 100A (4 pole version): RC 25/40/63A: 100A RC 80/100/125A: 125A FI trips are calibrated at less than fault trip current for ensured safety (Typical trip range between Fault Trip Current Calibration 66.6-83.3% fault trip current, e.g., typical trip at 20-25mA for fault RC of 30mA) Fully functional after 5,000 operations to DIN/VDE 0664T10, IEC 61008-1 and 2000 additional fault current trips. Typical Life Standard Pack and Weight 1/230g (0.6 lb.) 1/420-460g (0.9 lb.-1.0 lb.) 2 2 Terminal Size Acceptability 1.5-50mm (16-1 AWG) 1.5-50mm (16-1 AWG) Terminal Torque 3Nm (26.5 lb.in.) 3Nm (26.5 lb.in.) Circuit Diagram a, b a /N For 2-Phase applications, terminal 5 and 6 (next to Neutral terminals) must be connected to one phase for the test circuit to be operable. b For voltage systems without a neutral conductor. Please use jumper from 1 or 3 to top N terminal. This will assure proper functioning of the test /N circuit. RH11 - Auxiliary Contact and Signal Switch (switchable) (C.O./N.C.) Contact Wire Rating Size Torque Cat. No. Circuit Diagram 2 12 6A / 230V AC 1-1.5mm (16 AWG) max. 0.8Nm (7lb.in.) RH11 Note: If the power 21 system has a marked 1A / 110V DC conductor, it must 14 Std. Pk.: 1 connect through the FI 11 and not be grounded at Unit Weight: 45 grams (0.12 lb.) any point downstream. 22 Width: 9mm (.354in.) Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 P 908.806-9400 F 908.806.9490 www.altechcorp.com 86 Earth Leakage UL 1077 ANNEX UL 1077 UL 508 UL 489 Circuit Breakers Equipment Breakers CircuitProtection 2016.QXD CircuitProtection 4/4/16 12:25 PM Page 87 Dimensions in mm RP2 RP4 RP2 and RP4 Temperature Range Environmental Information marked with Snowflake approval for -25C to 40C (-13F to 104F) ambient temperature. (Temperature effect on RC: for every 10C temperature rise above 40C decrease RC by 7%.) Fluctuating Climate Conditions According to IEC 60068-2-30: heat (25C~55C), relative humidity (93%~95%) Electrical Shock Protection Uninsulated electrically live parts within 30mm of the operating handle are finger safe (terminal screw heads) and uninsulated live parts within 100mm of the operating handle are back-of- hand safe (terminals). 20g with impact force half-cycle sinusoidal and 20ms duration, 18 impacts total with 6 on each Impact/Shock Protection principal axis (3 impacts each face). FI is DIN Rail mounted during the test, and electrically loaded with 25% of Fault RC. Successful testing required no trip during the test, no damage and no loosened parts. 5g, at frequency of 80Hz, applied for 30 minutes along each of the three principal axes, plus 5 Vibration/Seismic Resistance minutes of application at every established critical resonant frequency. FI is DIN Rail mounted during the test, and loaded with 25% Fault RC. To pass, the FI did not trip at 25% Fault RC, but did trip between each of the principal axis tests when the fault current was raised to 125% Fault RC, and there was no damage and no loosened parts. Suitable for machinery and mobile vehicle applications. IP20 higher protection Class is dependent on housing. Protection Class The FI is tested and approval stamped for tripping sensitivity to non-sinusoidal fault currents, Non-Sinusoidal Fault which become zero or almost zero within one cycle of the line frequency. Waveforms and allowed trip-current ranges are as follows: 1. AC Sinusoidal Fault - 0.5-1.0 times Fault RC 2a. Pulsating DC Fault Positive and Negative Half-Waves - 0.35-1.4 times Fault RC 2b. Phased Half-Wave, 90 - 0.25-1.4 times Fault RC Phased Half-Wave, 135 - 0.11-1.4 times Fault RC 3. Pulsating DC on 6mA DC (continuous) Base - Max. 1.4 times Fault RC + 6mA At VDE rated voltage, suitable for Class C environments with relatively high dust and moisture Insulation Category levels and little HVAC control, e.g., industrial, commercial, agricultural on machine tools, hoists, warehouse equipment, etc. in boiler rooms, unheated storage, covered shipping/receiving, open workshops, etc. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 P 908.806-9400 F 908.806.9490 www.altechcorp.com 87 Earth Leakage UL 1077 ANNEX UL 1077 UL 508 UL 489 Circuit Breakers Equipment Breakers