RSR30 Slimline Interface Relays Optically isolated Applications: household appliances, temperature control system, industrial automatic control, Low on-state resistance light system, office appliances, factory appliances Low input power consumption Mounting: relays RSR30 are designed for direct PCB mounting, single in line package TTL and CMOS compatible RC networks (V AC) MOSFET output thyristor (V DC) E105728 AC Load - 2 A / 240 V Input circuit Nominal voltage Control voltage range Max. control current Release voltage Input resistance Part Number V DC V DC mA V DC k RSR30-D05-A1-24-020-1 5 310 12 1.0 0.32 RSR30-D12-A1-24-020-1 12 720 10 1.0 1.07 RSR30-D24-A1-24-020-1 24 1832 7.7 1.0 3.0 AC Load - 2 A / 240V Output circuit Nominal load current 1 A AC see Figure below Max. load current 2 A AC see Figure below Nominal load voltage rest condition: 240 V AC Load voltage range 12...280 V AC Non-repetitive peak voltage rest condition: 600 V AC Non-repetitive surge current operating state: 80 A Max. off-state leakage current rest condition: 1.5 mA Max. on-state voltage drop operating state: 1.2 V Min. load current operating state: 50 mA Off-state dV/dt max. allowable rate of voltage rise: 500 V/s Operating frequency range 47...400 Hz RC snubber 10 nF, 100 Operation resistance - Peak power dissipation - Operating switching frequency - Transient voltage suppressor - Max voltage of suppressor operation General data Output circuit switching moment R - instantaneous switching of the output circuit Max. turn-on time 100 s at rated voltage Max. turn-off time 1/2 cycle + 1 ms at rated voltage Insulation dielectric strength between input and output: 4 000 V AC 1 minute Dimensions (L x W x H) 28 x 5 x 15 mm Weight 4 g Storage temperature -40...+100C Operating temperature -20...+80 C rated value: +55 C see Figure below Max. solder bath temperature 220 C 10 s DIMENSIONS PIN OUTS Load current in the function of the ambient temperature and distances between relays 0.2 0.2 0.2 3.8 16.5 5.1 2 0.8 2 1.1 2.54 2.54 o Ambient temperature C BOLD - Regular stocked items. 84 Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com DATA SUBJECT TO CHANGE WITHOUT NOTICE Load current A RSR30 Slimline Interface Relays Optically isolated Applications: household appliances, temperature control system, industrial automatic control, Low on-state resistance light system, office appliances, factory appliances Low input power consumption Mounting: relays RSR30 are designed for direct PCB mounting, single in line package TTL and CMOS compatible RC networks (V AC) MOSFET output thyristor (V DC) E105728 DC Load - 2,5 A / 48 V Input circuit Nominal voltage Control voltage range Max. control current Release voltage Input resistance Part Number V DC V DC mA V DC k RSR30-D05-D1-04-025-1 5 310 12 1.8 0.32 RSR30-D12-D1-04-025-1 12 720 10 3.6 1.07 RSR30-D24-D1-04-025-1 24 1832 7.7 8.3 3.0 RSR30-D48-D1-04-025-1 48 3858 4.4 8.3 10.8 DC Load - 2.5A / 48V Output circuit Nominal load current 1 A DC see Figure below Max. load current 2.5 A DC see Figure below Nominal load voltage rest condition: 48 V DC Load voltage range 0...60 V DC Non-repetitive peak voltage rest condition: 100 V DC Non-repetitive surge current operating state: 6 A Max. off-state leakage current rest condition: 1 mA Max. on-state voltage drop operating state: 0.4 V Min. load current operating state: 1 mA Off-state dV/dt - Operating frequency range - RC snubber - Operation resistance operating state: 160 m at rated current Peak power dissipation 600 W Operating switching frequency 10 Hz Transient voltage suppressor Yes Max voltage of suppressor operation 60 V DC General data Output circuit switching moment R - instantaneous switching of the output circuit Max. turn-on time 50 s at rated voltage Max. turn-off time 600 s at rated voltage Insulation dielectric strength between input and output: 3 750 V AC 1 minute Dimensions (L x W x H) 28 x 5 x 15 mm Weight 4 g Storage temperature -25...+100C Operating temperature -20...+80 C rated value: +55 C see Figure below Max. solder bath temperature 220 C 10 s DIMENSIONS PIN OUTS Load current in the function of the ambient temperature and distances between relays 0.2 0.2 0.2 3.8 16.5 5.1 2 0.8 2 1.1 2.54 2.54 o Ambient temperature C BOLD - Regular stocked items. Altech Corp. 35 Royal Road Flemington, NJ 08822-6000 Phone (908)806-9400 FAX (908)806-9490 www.altechcorp.com 85 DATA SUBJECT TO CHANGE WITHOUT NOTICE Load current A