G3VM-61H1 MOS FET Relays MOS FET Relays Designed for Switching Minute Signals and Analog Signals. Continuous load current of 400 mA. RoHS compliant Note: The actual product is marked differently from the image shown here. Application Examples Terminal Arrangement/Internal Connections 6 54 Semiconductor test equipment Test & Measurement equipment OMRON logo Model name Communication equipment Pin 1 mark 932 LOT.No. Data loggers 132 Note: The actual product is marked differently from the image shown here. List of Models Minimum package quantity Load voltage Package type Contact form Terminals Model (peak value) * Number per tube Number per tape and reel G3VM-61H1 75 - 1a SOP6 Surface-mounting Terminals 60 V (SPST-NO) G3VM-61H1 (TR) -2,500 * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25 C) Item Symbol Rating Unit Measurement conditions Note: 1. The dielectric strength between the input and output was LED forward current IF 50 mA checked by applying voltage between all pins as a group on Repetitive peak LED forward current IFP 1 A 100 s pulses, 100 pps the LED side and all pins as a group on the light-receiving side. LED forward current reduction rate IF/ C 0.5 mA/C Ta 25C Connection Diagram LED reverse voltage VR 5 V Connection temperature TJ 125 C 1 6 Load Load voltage (AC peak/DC) VOFF 60 V Connection A 2 5 AC or Connection A 400 DC Continuous Connection A: AC peak/DC 3 4 Connection B IO 400 mA load current Connection B and C: DC Connection C 800 Connection A 4.0 ON current 1 6 Load reduction Connection B IO/C 4.0 mA/C Ta 25C Connection B 2 5 DC rate Connection C 8.0 3 4 Connection temperature TJ 125 C Dielectric strength between VI-O 1500 Vrms AC for 1 min 1 6 Load I/O (See note 1.) Connection C Ambient operating temperature Ta 40 to +85 C With no icing or condensation 2 5 DC Ambient storage temperature Tstg 55 to +125 C With no icing or condensation 3 4 Soldering temperature -260 C10 s Electrical Characteristics (Ta = 25 C) Item Symbol Minimum Typical Maximum Unit Measurement conditions LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Reverse current IR -- 10 A VR = 5 V Capacity between terminals CT - 30 - pF V = 0, f = 1 MHz Note: 2. Turn-ON and Turn-OFF Times Trigger LED forward current IFT -1.6 3 mA IO = 400 mA IF 1 6 RL VDD Connection A -1 2 IF = 5 mA, IO = 400 mA Maximum VOUT 2 4 resistance Connection B RON - 0.5 1 IF = 5 mA, IO = 400 mA with output ON Connection C -0.25 - IF = 5 mA, IO = 800 mA Current leakage when the relay is open ILEAK -- 1.0 A VOFF = 60 V Capacity between terminals Coff - 130 - pF V = 0, f = 1 MHz IF Capacity between I/O terminals CI-O - 0.8 - pF f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals RI-O 1000 - - M VI-O = 500 VDC, ROH 60 % 90% VOUT Turn-ON time tON - 0.8 2.0 ms IF = 5 mA, RL = 200 , 10% t ON t OFF VDD = 20 V (See note 2.) Turn-OFF time tOFF -0.1 0.5 ms 1 Output Input Output InputG3VM-61H1 MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD - - 48 V Operating LED forward current IF 57.5 25 mA Continuous load current (AC peak/DC) IO -- 400 mA Ambient operating temperature Ta 20 - 65 C Engineering Data LED forward current vs. Ambient Continuous load current vs. Ambient LED forward current vs. LED forward temperature temperature voltage IF - Ta IO - Ta IF - VF 100 1200 100 Ta = 25C 1000 30 80 Connection C 800 10 60 600 3 40 Connection A and B 400 1 20 200 0.3 0 0 0.1 0.6 0.8 1 1.2 1.4 1.6 1.8 -20 020 40 60 80 100 120 -20 020 40 60 80 100 120 Ambient temperature Ta (C) Ambient temperature Ta (C) LED forward voltage VF (V) Continuous load current vs. On-state On-state resistance vs. Ambient Trigger LED forward current vs. voltage temperature Ambient temperature IO - VON RON - Ta IFT - Ta 600 5 5 IO = 400 mA Ta = 25C IO = 400 mA t < 1s Connection A IF = 5 mA 400 Connection A IF = 5 mA 4 4 Connection A 200 3 3 0 2 2 -200 1 1 -400 -600 0 0 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 -20 020 40 60 80 100 -20 020 40 60 80 100 On-state voltage VON (V) Ambient temperature Ta (C) Ambient temperature Ta (C) Turn ON, Turn OFF time vs. LED Turn ON, Turn OFF time vs. Ambient Current leakage vs. Ambient forward current temperature temperature tON, tOFF - IF tON, tOFF - Ta ILEAK - Ta 5000 3000 30 Ta = 25C 3000 VOFF = 60 V tON VDD = 20 V 1000 10 RL = 200 1000 300 3 500 tOFF 300 100 1 tOFF 100 30 0.3 VDD = 20 V RL = 200 50 tON IF = 5 mA 30 10 0.1 1 3 5 10 30 50 100 300 -20 020 40 60 80 100 -20 020 40 60 80 100 LED forward current IF (mA) Ambient temperature Ta (C) Ambient temperature Ta (C) Safety Precautions Refer toCommon Precaution for all G3VM models. 2 Turn ON, Turn OFF time tON, tOFF (s) Continuous load current IO (mA) LED forward current IF (mA) Turn ON, Turn OFF time tON, tOFF (s) Continuous load current IO (mA) On-state resistance RON ( ) Trigger LED forward current IFT (mA) Current leakage ILEAK (nA) LED forward current IF (mA)