G3VM-101LR MOS FET Relays * Worlds Smallest SSOP Package MOS FET Relays with High Load Voltage of 100 V. Leakage current of 200 pA max. when output relay is open. * As of March 2011 Survey by OMRON RoHS compliant Note: The actual product is marked differently from the image shown here. Application Examples Terminal Arrangement/Internal Connections Semiconductor test equipment Test & Measurement equipment Model name 416 Communication equipment OMRON mark Data loggers 612 LOT.No. Note: The actual product is marked differently from the image shown here. List of Models Minimum package quantity Load voltage Package type Contact form Terminals Model (peak value) * Number per tape and reel G3VM-101LR - 1a SSOP4 Surface-mounting Terminals 100 V G3VM-101LR (TR05) 500 (SPST-NO) G3VM-101LR (TR) 1,500 Note: Ask your OMRON representative for orders under 1500 pcs or 500 pcs. We can supply products with the tape already cut. Tape-cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions. * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25 C) Item Symbol Rating Unit Measurement conditions LED forward current IF 50 mA LED forward current reduction rate IF/C 0.5 mA/C Ta 25 C LED reverse voltage VR 5 V Connection temperature TJ 125 C Load voltage (AC peak/DC) VOFF 100 V Continuous load current (AC peak/DC) IO 80 mA ON current reduction rate IO/C 0.8 mA/C Ta 25 C Connection temperature TJ 125 C Dielectric strength between VI-O 1500 Vrms AC for 1 min I/O (See note 1.) Note: 1. The dielectric strength between the input and Ambient operating temperature Ta 20 to +85 C With no icing or condensation output was checked by applying voltage Ambient storage temperature Tstg 40 to +125 C With no icing or condensation between all pins as a group on the LED side and Soldering temperature - 260 C10 s all pins as a group on the light-receiving side. Electrical Characteristics (Ta = 25 C) Item Symbol Minimum Typical Maximum Unit Measurement conditions LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times Reverse current IR - - 10 A VR = 5 V IF 1 4 RL VDD Capacity between terminals CT - 15 - pF V = 0, f = 1 MHz VOUT 2 3 Trigger LED forward current IFT -1 5 mA IO = 80 mA Maximum resistance with output ON RON -8 14 IF = 10 mA, IO = 80 mA, t = 10 ms Current leakage when the relay is open ILEAK -- 200 pA VOFF = 80 V Capacity between terminals COFF - 6 8 pF V = 0, f = 100 MHz, t < 1 s IF Capacity between I/O terminals CI-O - 0.6 - pF f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals RI-O 1000 - - M VI-O = 500 VDC, ROH 60 % 90% VOUT 10% Turn-ON time tON - 0.1 0.3 ms IF = 5 mA, RL = 200 , t ON t OFF VDD = 20 V (See note 2.) Turn-OFF time tOFF - 0.1 0.3 ms 1 Output Input Output InputG3VM-101LR MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) VDD -- 80 V Operating LED forward current IF 10 - 30 mA Continuous load current (AC peak/DC) IO -- 80 mA Ambient operating temperature Ta 25 - 60 C Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature LED forward current vs. LED forward voltage IF - Ta IO - Ta IF - VF 100 120 100 Ta = 25 C 100 80 80 10 60 60 40 40 1 20 20 0 0.1 0 -20 0 20 40 60 80 100 120 0.6 0.8 1 1.2 1.4 1.6 1.8 -20 0 20 40 60 80 100 120 Ambient temperature Ta (C) LED forward voltage VF (V) Ambient temperature Ta (C) Continuous load current vs. On-state voltage On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature IO - VON RON - Ta IFT - Ta 3030 100 55 IO = 80 mA Ta = 25 C IO = 80 mA 80 IF = 10 mA, t < 1 s IF = 10 mA t < 1 s 60 44 40 2020 20 33 0 -20 22 1010 -40 -60 11 -80 00 -100 00 -1 -0.5 0 0.5 1 -20 0 20 40 60 80 100 -20 0 20 40 60 80 100 On-state voltage VON (V) Ambient temperature Ta (C) Ambient temperature Ta (C) Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time vs. Ambient temperature Current leakage vs. Load voltage tON, tOFF - IF tON, tOFF - Ta ILEAK - VOFF 5000 5000 100 3000 3000 VDD = 20 V Ta = 25 C Ta = 25 C VDD = 20 V RL = 200 IF = 5 mA RL = 200 1000 1000 80 500 500 300 300 tON tOFF 60 100 100 tOFF 50 50 30 30 40 10 10 tON 5 5 20 3 3 1 1 0 -20 0 20 40 60 80 100 113355000100 020 40 60 80 100 LED forward current IF (mA) Ambient temperature Ta (C) Load voltage (V) Output terminal capacitance vs. Load voltage COFF - VOFF 10 Ta = 25 C 8 6 4 2 0 010 20 30 40 Load voltage (V) Safety Precautions Refer toCommon Precaution for all G3VM models. 2 LED forward current IF (mA) Turn ON, Turn OFF time tON, tOFF (s) Continuous load current IO (mA) Output terminal capacitance COFF/COFF (pF) On-state resistance RON ( ) Continuous load current IO (mA) Turn ON, Turn OFF time tON, tOFF (s) LED forward current IF (mA) Current leakage ILEAK (pA) Trigger LED forward current IFT (mA)