T: +48 799 709 902 SGX Europe Sp. z o.o. E: sales.is sgxsensortech.com 103 Ligocka Str. 40-568 Katowice www.sgxsensortech.com Poland Integrated IR-RF-R290 Datasheet DS-0304 INIR-RF-R290, ISSUE 2 Copyright SGX Sensortech 2012-2019 GENERAL DESCRIPTION The Integrated IR (INIR) sensor has been designed with the latest technology, using a microcontroller with an ARM7 core and via software design the necessary techniques have been implemented to increase the reliability of the device therefore minimize the probability of faults. The INIR is a user friendly digital Gas Sensor, which is designed to use the latest SGX Sensortechs Infrared technology. Integrated IR FEATURES The sensor is designed to decrease the implementation time therefore increase productivity. The Integrated IR sensor incorporates the necessary electronics and embedded software to operate from a low voltage DC power supply. The Gas Sensor with Automatic Switchover between ranges, sensor will process the raw signals to output a linear, High Resolution up to 20ppm, temperature compensated signal proportional to the gas Detectivity Level at 100ppm, concentration applied. The output signal is available in digital Multi-sensor mode, and analogue forms. Analog Output of gas concentration, The SGX Sensortech Integrated IR Gas Sensor provides Serial port communication, users with a simple method of incorporating an Infrared Internal Temperature sensor Sensor into their gas detection instrument which will Active & Reference Signals Monitored significantly reduce the development time and expertise Full Faults Diagnostics & Error Generation required during the design and implementation phase. The Cyclic Redundancy Check (CRC) Integrated IR can also be factory calibrated to allow Typical Low power consumption < 100mW (Average) installation without the need for recalibration. Factory calibrated for Propane or Carbon Dioxide Evaluation Kit available including PC software for easy RECOMMENDED APPLICATIONS testing and production calibration functions Easy implementation into Sensors Network Automation & Control Design for use in Hazardous Areas Indoor Air Quality Certified Sensor for use in Explosive Atmospheres (EX) Industrial Health & Safety Whilst SGX Europe Sp. z o.o. has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. SGX Europe accepts no liability beyond the set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein. In case of modification of the product, SGX disclaims all liability. Copyright SGX Europe Sp. z o.o. 2012-2019 DS-0304 INIR-RF-R290, ISSUE 2, October 2019 Page 2 of 7 Integrated IR(INIR) Datasheet TECHNICAL SPECS ABSOLUTE MAXIMUM RATINGS PIN CONFIGURATION Power Supply Min Typical Max Pin Name Description Supply Voltage 3.2 VDC 3.3 VDC 5.25 VDC 1 TXD Data transmitted from the Integrated IR. Average Current 30mA 32mA 35 mA* 3.2 Volts 5.25 Volts DC input to Integrated *Inrush Current can be up to 65mA 2 +VCC Consumption IR Logic Outputs Level LOW Voltage Level(VOL) : GND Plane, 0 Volts reference for Integrated 0.6V Maximum 3 GND IR HIGH Voltage Level(VOH): 4 RXD Data received by the Integrated IR. 2.0V Minimum Analog Output. Scalable range, see 1.6mA source current maximum 5 OUT Application Note 1 Integrated IR Protocol & Logic Inputs Level LOW Voltage Level(VINL): 0.4V Maximum Calibration for details. HIGH Voltage Level(VINH): Pad Pad Bootloader Pad. Not used by the customer. 2.0V Minimum Humidity Operating Humidity 0% 50% 99% NOTE1: All Dimensions in mm. All tolerances Linear +/- o Storage Humidity 0% 50% 90% 0.1mm and Angular 0.5 unless otherwise stated. Condensation Sensors Detection Limit, Stability & (>100% Humidity) Linearity would be affected, algorithms NOTE2: Do not solder pins. INIR Series sensors are are implemented to minimize as the designed to press-fit into PCB sockets. The end-user should effect. choose a socket to accommodate the full sensor pin length. Temperature This will ensure a stable mechanical location as well as Operating Temp. -40 C +20 C +75 C good electrical contact. SGX Sensortech recommend the Storage Temp. -20 C +20 C +55 C Wearns Cambion type 450-1813-01-03-00 single-pole o o Temp. Cycle Limits 0.8 C/min 1.3 C/min solder mount socket with through hole, or a suitable Pressure ( Compensation will be required ) equivalent. Operating Pressure 80kPa - 120kPa Storage Pressure 80kPa - 120kPa Performance DAC Resolution 12-Bit at 0.0-2.5 Volts DC Max Scalable according to Gas Conc. Operating Range Digital signal format 8 data bits, 1 stop bit, no parity Standard baud rate 38400 as default, 115200, 19200, 9600 Dimensions Diameter (D) 19.9mm 20mm 20.1mm Height (H) 16.50mm 16.60mm 16.70mm Pins Height (pH) 4.0mm 4.8mm 5.6mm Body Material Stainless Steel Weight 25 g 29 g 33 g Gas Sensor Sockets 5-Pin , Polygon Topology S1 Whilst SGX Europe Sp. z o.o. has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. SGX Europe accepts no liability beyond the set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein. In case of modification of the product, SGX disclaims all liability. Copyright SGX Europe Sp. z o.o. 2012-2019 DS-0304 INIR-RF-R290, ISSUE 2, October 2019