NPC-1210 Series NovaSensor Medium/Low Pressure Sensors Features Applications High sensitivity Industrial automation High accuracy Air flow monitors Interchangeable Process control Temperature compensated 0C to 60C (32F to 140F) Medical equipment PCB mountable package Underground cable leak detection DIP package Ventilation Solid-state reliability Individual device traceability Respirator monitoring Amphenol Advanced Sensors0.6 in (15.24 mm L, S (See Notes) NPC-1210 Series Specifications Description 1 Pressure Sensor + - -Out A2 The NPC-1210 series of solid-state pressure sensors - are designed to provide a cost effective solution for R applications that require calibrated performance over +In 5 100 kW 4 1.5 mA a wide temperature range. Packaged in a dual-in-line 3.012V Gain Amplified FSO configuration, the NPC-1210 Series is intended for Set 6 100 kW printed circuit board mounting. Optional pressure port R and lead configurations provide superior flexibility in - + low profile applications where pressure connection A3 +Out + I orientation is critical. 3 -In 7 8 2 The NPC-1210 series is based on NovaSensors NC NC advanced SenStable piezoresistive sensing Ground technology. Silicon micromachining techniques Lead Connection are used to ion implant piezoresistive strain gages 1 -Out into a Wheatstone bridge configuration. The NPC- 2 -In 3 +Out 1210 Series offers the added advantage of superior 4 +In temperature performance over the temperature 5,6 Gain-Set Resistor compensated range of 0C to 60C (32F to 140F). A 7,8 No Connection gain set resistor is included to normalize the FSO for field interchangeability. NPC-1210 Series Schematic Diagram 0.60 in (15.24 mm) 0.15 in 0.1 in (3.8 mm) (2.54 mm) 8 7 6 5 0.32 in 0.2 in (8.1 mm) (5.1 mm) G6 1 2 3 4 0.12 in (3.05 mm) 0.37 in (9.4 mm) Diameter 0.127 in (3.23 mm), Two tubes Used for positive differential (P2) Not used for gauge (P1) Not used for absolute (1) Ceramic 0.167 in substrate (4.2mm) 8X 0.07 in (1.78mm) 8X 0.34 in (3) (8.6 mm) 8X 0.02 in (0.51 mm) 1. All dimensions are for reference only. 2. Tube length: L = 0.49 in (12 mm), S = 0.33 in (8.3 mm), N = No tube 3. Lead pins can be either in the same or the opposite direction of the pressure tube. Option (1) has the leads in theU position, the same direction as the tube. Option (3) has the leads in theDow position, the opposite direction from the tube. 4. Gauge and differential pressure devices are calibrated by applying pressure to the positive differential port (P2) and venting to atmosphere the reference port (P1). Absolute pressure devices use only P1 to apply vacuum or pressure. NPC-1210 Series Package Diagram