SGX Europe Sp. Z o.o. T: +48 (0) 32 438 4778 Building 11 Ligocka St. 103, E: sales.is sgxsensortech.com 40-568 Katowice, www.sgxsensortech.com Poland SGX-4CO-10k Datasheet OUTLINE Industrial Carbon Monoxide (CO) Sensor for high concentrations All dimensions are in mm All tolerances are 0.15mm PERFORMANCE Output signal 20 10 nA / ppm Typical Baseline Range 20ppm CO equivalent (pure air) Filter Capacity >20 000 ppm hours T90 Response Time < 40 seconds Measurement Range 0 10 000 ppm Maximum Overload 100 000 ppm Linearity Linear up to 2000ppm Repeatability < 2% CO equivalent Recommended Load 10 ohms Resistor Resolution (Electronics <5 ppm typical dependent) OPERATING CONDITIONS Temperature Range -30C to +50C Pressure Range 800 to 1200 mbar Operating Humidity Range 15%-90% RH LIFETIME INTRINSIC SAFETY DATA Long Term Output Drift < 5% per annum Max at 2000ppm 0.3 mA Recommended Storage 0C to 20C Max o/c Voltage 1.3 V Temp Expected Operating Life > 24 months in air Max s/c Current <1.0 A SGX Sensortech 2012-2020 DS-0321 SGX-4CO-10k, Issue 1, 26-Mar-2020, Page 1/3 SGX Europe Sp. Z o.o. T: +48 (0) 32 438 4778 Building 11 Ligocka St. 103, E: sales.is sgxsensortech.com 40-568 Katowice, www.sgxsensortech.com Poland CROSS SENSITIVITY DATA GAS CONCENTRATION SGX-4CO-10k Hydrogen Sulphide 50 ppm <0.1 ppm Sulphur dioxide 20 ppm 0 ppm Hydrogen 100 ppm <35 ppm Nitric Oxide 50 ppm <10 ppm Ethanol 200 ppm <1 ppm Ammonia 50 ppm 0 ppm Chlorine 15 ppm <1 ppm Ethylene 100 ppm 96 ppm Acetylene 100 ppm 90 ppm * See Important Notes Output vs Temp SGX Sensortech 2012-2020 DS-0321 SGX-4CO-10k, Issue 1, 26-Mar-2020, Page 2/3