T3022 Series IP65 CO Sensor for 2 OEM Installation Designed to meet the needs of OEM manufacturers for low cost Carbon Dioxide (CO ) sensor 2 installations, the Telaire T3022 Series provides reliable and convenient CO measurement in an 2 IP65-rated enclosure. Compatible with other sensors in the Amphenol Advanced Sensors product 2 portfolio, the T3022 easily integrates into environmental monitoring and control systems via I C serial communication protocols. Applications Features An affordable gas sensing solution for OEMs Air-air heat exchanger volume control A reliable sensor design based on 25 years Residential demand-based ventilation of engineering and manufacturing expertise Self-contained ventilation system control Flexible CO sensor platform designed to 2 interact with other microprocessor devices Accurate Carbon Dioxide (CO ) Transmitter 2 for HVAC control applications Eliminates the need for calibration in most applications with Telaires patented ABC Logic software. Lifetime calibration warranty. Easy mounting with external tab Different calibrations available, subject to commercial consideration Extended operating temperature range Digital output Non-Dispersive Infrared (NDIR) measuring technology Sensors are shipped factory-calibrated IP65 ingress protection ensures reliable operation in harsh environments Amphenol Advanced SensorsTelaire T3022 Series Specifications Method Output 2 Non Dispersive Infrared (NDIR), gold plated optics, I C Digital, see T6700 Series Application Guide for diffusion or flow through sampling (with Telaires detail Patented ABC Logic Self Calibrated Algorithm) Protection Measurement Range IP65 0 to 5000 ppm** Power Supply Requirements Overall Dimensions 4.5-5.5 VDC 60mm X 35mm X 15 mm (approx) Peak 200mA (155mA typical) Average 25mA (20mA typical) Accuracy 400-5000 ppm 75 ppm or 10% of reading, Pin Designations whichever is greater* JST EHR-4 connector Mating PCB Connector JST B4B-EH-A or S4B-EH Temperature Dependence 0.2% FS per C 1. V+ 2. Ground 3. SDA Stability 4. SCL < 2% of FS over life of sensor (15 years typical) Molex 22-01-3047 Pressure Dependence PCB Connector Molex 171856-0004 0.13% of reading per mm Hg 1. SCL Calibration Interval 2. SDA Not required 3. Ground 4. V+ Response Time 7 minutes (approximate) Warranty Terms 12 months Signal Update Every 4 seconds Compliance REACH, ROSH and Prop65 compliance Warm Up Time Flammability rating of enclosure UL94 5VA < 2 minutes (operational) 10 minutes (maximum accuracy) Operating Conditions 32F to 122F (0C to 50C) * Tolerance based on span gas of 2% 0 to 95% RH, non-condensing ** Subjecting sensors to environments less than 400 ppm for more than 15 minutes may affect Storage Conditions accuracy due to ABC Logic algorithm. -40F to 158F (-40C to 70C)