T3030 Series CO Sensors for 2 Harsh Environments with Analog Outputs Telaire T3030 Series is a range of Carbon Dioxide (CO2) Sensors designed to meet the specific needs of customers who require measuring CO2 in harsh or difficult environments. Based on a series of modules, the casing offers a number of combinations to meet the needs of range, supply voltage, and output type in various applications. Example applications include incubators, buses, refrigerators, subway stations, and railway carriages, in addition to agricultural applications, such as glass houses, mushroom sheds, and pig and chicken sheds. Features Accurate CO transmitter for HVAC Analog or digital output options 2 control applications Non-Dispersive Infrared (NDIR) measuring Easy mount with 2 external tabs technology Rated up to IP67 (build dependent) Sensors are shipped factory-calibrated Available with potting Accuracy for 10 year life Different calibrations available up to 20% Extended operating temperature range CO concentration 2 Amphenol Advanced SensorsT3030 Series Specifications Sensing Method Storage Temperature Non-Dispersive Infrared (NDIR), single or dual -40 to +70C wavelength Minimum Lifetime Power Supply Requirements 10 years or 30,000 operating hours 15 15 VDC 10% Flammability Classification 24 - 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, To UL94 5VA (dependent upon build) polarity protected RH Range Power Consumption 0% to 99% RH (non-condensing) Typical 0.7 W at nominal voltage of 24V AC RMS Atmospheric Conditions Range Sensors have been designed and tested to the See Ordering Information for calibrated ranges following However, not all models are as capable Resolution please discuss your application with Telaire. Minimum 10bit or analog equivalent Marine, salt mist and particles present Accuracy 0 level 0-21 vol% 2 Single Wavelength 0 to 100% RH. 3 (0~2,000 ppm as example) Ammonium max 200mg/m 400-1250 ppm 30 ppm or 3% of reading, S0 max 0,5 vol% 2 whichever is greater*,** Ethylene max 500ppm vol 1250-2000 ppm 5% of reading + 30ppm *, ** Ozone Dual Wavelength IP Class (0~2,000 ppm range as example) Up to IP67, dust tight and immersion to 1m. 75 ppm or 10% of reading (whichever is greater) Optional potting (0~200,000 ppm range as example) Discuss your requirement with Telaire. 5% of reading or 0,3 vol% CO (whichever is 2 larger) at 0 - 20 vol% CO and 0C to +25C 2 At 25C to 50C additional 0,1% of reading or Output Configurations 0,01 vol% CO (whichever is larger) per degree 2 Analog* C. 0 to 5 V *Tolerance based on span gas of 2% 0 to 10 V ** ABC Logic not deactivated 4 to 20mA Temperature Dependence 0.2% FS / C *Digital to Analog Error 1% Response Time, tau (63%) < 200 sec Aging (Dual Wavelength Only) +/- 5% of reading annual drift. Less than +/- 25% of reading within product life time. Recommended Recalibration Interval Single Wavelength No calibration required Dual Wavelength - 1 year Working Temperature 0 to +50C (measures within tolerance) Operation Temperature (Sensor Is Powered) -30 to +50C