Telaire T5100 Series Low-Cost Wall Mount CO Transmitter 2 The new Telaire T5100 series is a new low cost, high performing CO transmitter for the building 2 controls market. It works seamlessly with building automation systems, and allows you to simply and effectively control fresh air. Demand-controlled ventilation using CO sensors prevents energy 2 losses from over-ventilation while maintaining indoor air quality. Features: Patented, Absorption Infrared Gas sensing Sensors are shipped factory calibrated. engine provides high accuracy in a compact low cost package. Modern enclosure Patented ABC Logic self-calibration Low-cost system eliminates the need for manual calibration in most applications. Reliable (20 years of low-cost infrared sensor manufacturing) Lifetime CO calibration guarantee when 2 using ABC Logic. Available output options: - Voltage 0-10V or 0-5V (jumper selectable) Mounting plate with two-piece terminal - Current 4-20 mA blocks provide quick, easy wiring. UIP software compatible for customizations Gas permeable, water resistant CO 2 diffusion filter prevents particulate and water CE, RoHS, REACH and WEEE compliant contamination of the sensor. Lifetime calibration warranty Locking screw secures cover and sensor to the mounting bracket for tamper resistance. Two enclosure sizes for regional acceptance Amphenol Advanced SensorsControlled Ventilation Ventilation is an important part of maintaining a Numerous organizations now require and/or recommend comfortable, healthy, productive environment for people. CO -based ventilation control in different commercial 2 Improper ventilation can have a negative impact on HVAC applications. Some utility companies also offer occupant health and performance, increase the risk rebates to building owners for installing CO sensors. 2 from litigation, and/or waste energy. Demand-controlled Wall mount sensors are used to control a specific area ventilation using CO sensors prevents energy losses 2 such as a conference room, classroom, meeting hall, from over-ventilation while maintaining indoor air quality. etc. The Telaire 5100 Ventostat series are easy to install The most energy savings potential is in buildings where and have a clean, modern look that suits most indoor occupancy fluctuates during a 24-hour period. environments. T5100 Series Wall Mount Specifications Sensing Method Warranty Non-dispersive infrared (NDIR) absorption 24 months on mechanical defects Gold-plated optics Calibration - lifetime warranty (ABC Logic on.) Patented ABC Logic self calibration algorithm Certifications CO Measurement Range CE EMC, RoHS, REACH and WEEE compliant 2 0 to 2000 ppm Signal Update (0 ppm = 0 V, 4 mA) Every 5 seconds CO Accuracy 2 CO Warm-up Time 30 ppm or 3% of the reading shown,whichever is higher* 2 < 2 minutes (operational) Power Supply Requirements 10 minutes (maximum accuracy) 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, Operating Conditions polarity protected 32F to 122F (0C to 50C) 0 to 95% RH, non-condensing *AHRAE regulation 62 states maximum indoor CO2 level of 1000 ppm Storage Conditions -40F to 158F (-40C to 70C) Power Consumption Typical 0.7 W at nominal voltage of 24V AC RMS Flammability Classification UL94 5VA Temperature Dependence 0.2% FS per C (0.11% per F) Output Stability <2% of FS over life of sensor (15 years) Analog (CO ) 2 0 to 5 V, or 0 to 10 V jumper selectable (100 output Pressure Dependence impedance) 0.135% of reading per mm Hg Or 4 to 20 mA (RL maximum 500 ) Voltage and current outputs are not available *C0 accuracy statement excludes standard gas used for simultaneously 2 calibration that has an accuracy of 2%. In addition, there is Digital to analog error 1% a potential digital to analog error of up to 2%.