Telaire 6613 CO Module 2 Small, Compact CO 2 Module Designed to Integrate Into Existing Controls and Equipment The Telaire 6613 CO Module is designed to meet 2 Features the volume, cost, and delivery expectations of Original Equipment Manufacturers (OEMs). The An affordable gas sensing solution for OEMs. module is ideal for customers who are familiar with the design, integration, and handling of A reliable sensor design based on 15 years of electronic components. engineering and manufacturing expertise. All units are factory calibrated to measure CO 2 Flexible CO sensor platform designed to interact 2 concentration levels up to 2000 and 5000 ppm. with other microprocessor devices. Telaire dual channel sensors are available for higher concentrations. Eliminates the need for calibration in most applications with Telaires patented ABC Logic Telaire offers high-volume manufacturing software. Lifetime calibration warranty. capabilities, a global sales force, and additional engineering resources to support your sensing application needs. Amphenol Advanced Sensors0.062 in 1.75 in Telaire 6613 CO Module (0.1575 mm) 2 (44.45 mm) 0.38 in 2 Mounting Holes .105 (2.667) (9.65 mm) Specifications Method Non Dispersive Infrared (NDIR), gold plated optics, diffusion or flow through sampling (with Telaires Patented ABC Logic Self Calibrated Algorithm) 0.15 in (3.81 mm) 0.54 in Measurement Range (13.7 mm) 1.125 in 0 to 2000 ppm** (28.575 mm) 0.60 in 2.25 in (15.24 mm) (57.15 mm) Dimensions Output 2.25 in X 1.365 in X 0.60 in (57.15 mm X 34.67 mm X 15.24 mm) Digital UART 19200 Baud (Please call for detailed product Accuracy* specifications). 400-1250 ppm 30 ppm or 3% of reading, 2 I C slave up to 100 kHz whichever is greater* 1250-2000 ppm 5% of reading + 30ppm* Analog 0 to 4 VDC Temperature Dependence 0.2% FS per C Power Supply Requirements 5 VDC regulated (5%) Stability < 2% of FS over life of sensor (15 year typical) Power Consumption 0.90 watts peak Pressure Dependence 0.165 watts average 0.13% of reading per mm Hg Interface Connections Calibration Interval Designed for 12 pin male header with 0.1 in (2.54 mm) Not required spacing. Header not included. Response Time Flow Rates (Via Flow Ports) < 2 minutes for 90% step change typical Flow through version 40 to 50 cc/min Signal Update Warranty Terms Every 4 seconds 12 months Warm Up Time *Tolerance based on span gas of 2% < 2 minutes (operational) 10 minutes (maximum accuracy) ** Subjecting sensors to environments less than 400 ppm for more than 15 minutes may affect accuracy Operating Conditions due to ABC Logic algorithm. 32F to 122F (0C to 50C) 0 to 95% RH, non condensing Storage Conditions -40F to 158F (-40C to 70C) 1.365 in (34.67 mm) 1.24 in (31.5 mm)