Telaire T6713 Series CO Module 2 NDIR CO Module 2 designed for applications that require high accuracy in a compact package The Telaire T6713 CO Series is ideal for 2 Features applications where CO levels need to be 2 measured and controlled for indoor air quality An affordable gas sensing solution for OEMs. and energy saving applications such as demand control ventilation. Eliminates the need for calibration in most applications with Telaires patented ABC All units are factory calibrated to measure CO 2 Logic software. Lifetime calibration concentration levels up to 5000 ppm. warranty. A reliable sensor design based on 20 years of Engineering and manufacturing expertise. Flexible CO sensor platform designed to 2 interact with other microprocessor devices. Small compact design allowing simple product integration. Amphenol Advanced SensorsTelaire T6713 series CO 2 Module Specifications Method Non Dispersive Infrared (NDIR), gold plated optics, diffusion sampling (with Telaires Patented ABC Logic Self Calibrated Algorithm) (2) Measurement Range 0 to 5000 ppm Dimensions 1.18in X 0.787in X 0.34in (30mm X 15.6mm X 8.6mm) All dimensions in millimeters (mm) (1) (5) Accuracy Output + 400-5000 ppm /- 30 ppm 3% of reading + 400-2000 ppm /- 25 ppm 3% of reading (3) Digital 2 I C slave up to 100kHz Temperature Dependence UART 19200 Baud w/Modbus support 5 ppm per C or 0.5% of the reading per C, whichever is greater PWM Output Mode Two options: Stability Cycle period 1002 ms (~1Hz) < 2% of FS over life of sensor (15 years typical) 40 us (25kHz) (4) Pressure Dependence Power Supply Requirements 0.13% of reading per mm Hg 4.5-5.5 VDC Peak 200mA (155mA typical) Average 25mA (20mA typical) Calibration Interval Not required Interface Connections Designed for six (6) pin male header with Response Time 0.1 in (2.54 mm) spacing. Header not included. < 3 minutes for 90% step change typical Signal Update Every 5 seconds Notes: (1) Tolerance based on span gas of 2%, which adds to the uncertainty, tested at Standard Warm Up Time Ambient Temperature and Pressure (SATP). < 2 minutes (operational) 10 minutes (maximum accuracy) (2) Subjecting sensors to environments less than 400 ppm for more than 15 minutes may affect accuracy due to ABC Logic algorithm. Operating Conditions 14F to 140F (-10C to 60C) (3) Please call for detailed product specifications. 0 to 95% RH, non-condensing (4) Based on nominal 5VDC input voltage. For best performance, DC supply should Storage Conditions be a regulated, low noise power source. -22F to 158F (-30C to 70C) (5) The module may exhibit a tolerance addition of 60ppm when first installed. This will be corrected by the ABC Logic in first weeks of operation.