Telaire T8000-R Series Wall Mount CO and 2 Temperature Transmitter with Relay The new Telaire T8000-R series is a new low cost, Gas permeable, water resistant CO diffusion filter 2 prevents particulate and water contamination of the high performing CO transmitter for the building 2 sensor. controls and indoor growers markets. It works seamlessly with building automation systems, and Locking screw secures cover and sensor to the allows you to simply and effectively control fresh air mounting bracket for tamper resistance. into a ventilated space to meet regulated standards, providing immediate energy savings. Relay control Sensors are shipped factory calibrated. can be used to control fresh air when no building automation system is available. The Telaire 8000- Modern enclosure R series can also be used with its built-in relay to control CO producing equipment to assist with plant 2 Conformal coating on 0-5000 ppm models growth. Low-cost Features: Reliable (20 years of low-cost infrared sensor Patented, Absorption Infrared Gas sensing engine manufacturing) provides high accuracy in a compact low cost package. Available CO and Temperature output options: 2 Voltage 0-10V or 0-5V (switch selectable) Patented ABC Logic self-calibration system Or current 4-20 mA, Relay eliminates the need for manual calibration in most applications. UIP software compatible for customizations Lifetime CO calibration guarantee when using ABC 2 CE, RoHS, REACH and WEEE compliant Logic. Lifetime calibration warranty Mounting plate with two-piece terminal blocks provide quick, easy wiring. Amphenol Advanced SensorsControlled Ventilation Ventilation is an important part of maintaining a comfortable, Warranty healthy, productive environment for people. Improper 24 months on mechanical defects ventilation can have a negative impact on occupant health Calibration - lifetime warranty (ABC Logic on.) and performance, increase the risk from litigation, and/ Certifications or waste energy. Demand-controlled ventilation using CO 2 CE EMC, RoHS, REACH and WEEE compliant sensors prevents energy losses from over-ventilation while maintaining indoor air quality. The most energy savings Signal Update potential is in buildings where occupancy fluctuates during Every 5 seconds a 24-hour period. Numerous organizations now require and/ or recommend CO -based ventilation control in different 2 CO Warm-up Time 2 commercial HVAC applications. Some utility companies also < 2 minutes (operational) offer rebates to building owners for installing CO sensors. 2 10 minutes (maximum accuracy) Wall mount sensors are used to control a specific area such Operating Conditions as a conference room, classroom, meeting hall, etc. The 32F to 122F (0C to 50C) Telaire 8000-R Ventostat series are easy to install and have a 0 to 95% RH, non-condensing clean, modern look that suits most indoor environments. Storage Conditions -40F to 158F (-40C to 70C) Wall Mount Specifications Flammability Classification UL94 5VA Sensing Method Non-dispersive infrared (NDIR) absorption Gold-plated optics Relay Patented ABC Logic self calibration algorithm Normally open and normally close contacts CO Measurement Range Rated Load 2 8100-R 0 to 2000 ppm 0.50 A at 125 VAC, 1A 24 VDC 8200-R 0 to 5000 ppm Contact Material (0 ppm = 0 V, 4 mA) Ag + Au-Alloy CO Accuracy Carry current 2 A 2 30 ppm or 3% of the reading shown, whichever is higher * Max. Operating Voltage Active Temperature Accuracy /Range 125 VAC, 60 VDC 0-50C (32-122F) 1C from 15-30C (1.8F from 59 to 86F) Max. Operating Current 1 A Power Supply Requirements 18-30 VAC RMS, 50/60 Hz, or 18 to 42 VDC, Max. Switching Capacity polarity protected 62.50 VA *AHRAE regulation 62 states maximum indoor CO 2 Output level of 1000 ppm Analog (Temperature and CO ) Power Consumption 2 0 to 5 V, or 0 to 10 V switch selectable (100 output Typical 0.7 W at nominal voltage of 24V AC RMS impedance) Temperature Dependence Or 4 to 20 mA (RL maximum 500 ) 0.2% FS per C (0.11% per F) Voltage and current outputs are not available simultaneously Stability Digital to analog error 2% <2% of FS over life of sensor (15 years) Pressure Dependence 0.135% of reading per mm Hg *C0 accuracy statement excludes standard gas used for 2 calibration that has an accuracy of 2%. In addition, there is a potential digital to analog error of up to 2%.