Evaluates: MAX30110 and MAX30112 MAX30110 Evaluation Kit General Description Quick Start The MAX30110 evaluation kit (EV kit) allows for the quick Required Equipment evaluation of the MAX30110 and MAX30112 optical AFE MAX30110 EV Kit for applications at various sites on the body, particularly MAX30110 EV Kit Micro-PCB the wrist. MAX30110 supports standard SPI compatible (MAX30110 UC EVKIT) 2 interface, whereas MAX30112 supports I C compatible MAX30110 EV Kit Sensor PCB 1 interface. The EV kit allows flexible configurations to (MAX30110 OSB EVKIT) optimize measurement signal quality at minimal power MAX30110 EV Kit Sensor PCB 2 consumption. The EV kit helps the user quickly learn how (MAX30110 SFH7050 EVKIT) to configure and use the MAX30110 and MAX30112. 10-pin Flex cable The EV kit consists of three boards. MAX30110 UC Micro-USB cable EVKIT is the main data acquisition board while MAX30110 MAX30110 EV Kit GUI Software SFH7050 EVKIT and MAX30110 OSB EVKIT are the Windows PC sensor daughter boards in which the MAX30110 devices are placed in different optical configurations. The EV kit is Procedure powered using the USB supply to generate +1.8V for the 1) The EV kit is fully assembled and tested. AFE and accelerometer and +4.5V for the LEDs. Follow the steps below to verify board operation: The EV kit comes with a MAX30110EWG+ in a 24-bump Visit www.maximintegrated.com/evkit-software wafer-level package (WLP). to download the most recent version of the EV kit software, MAX30110GUISetupVxxx Web.ZIP. Features Save the EV kit software to a temporary folder and uncompress the ZIP file. Quick Evaluation of the MAX30110 2) Open up MAX30110GUISetupVxxx.exe and follow Supports Optimization of Configurations the instructions from the pop-up windows as shown in Facilitates Understanding MAX30110 Architecture Figure 1, Figure 2, Figure 3, and Figure 4. and Solution Strategy 3) If the MAX30110 EV kit 10-pin flex cable is not Real-Time Monitoring already connecting the MAX30110 EV kit micro- Data-Logging Capabilities PCB to the MAX30110 EV kit sensor PCB 1/2, then connect the two PCBs with the cable as shown in USB-Powered Figure 5, Figure 6, Figure 7, Figure 8, and Figure 9. On-Board Accelerometer 4) Use the micro-USB cable to connect the MAX30110 EV Kit micro-PCB to any USB adapter in a Window 7, or Window 10 compatible PC. Ordering Information appears at end of data sheet. 5) After that, start the MAX30110 EV kit GUI program. The GUI will be launched as shown in Figure 10. 6) Look for the Connected statement in the lower right hand of the GUI as shown in Figure 10. If Discon- nected is shown in the Connection Status, please check the USB connection. 7) Click on the <Start Monitor> button on the left side to start the data acquisition. 8) When running, the LEDs on the micro-PCB should illuminate and the five graphs on the GUI should stream with data. 319-100029 Rev 1 7/17Evaluates: MAX30110 and MAX30112 MAX30110 Evaluation Kit Figure 1. MAX30110 EV KitSetup GUI Software Step 1 Maxim Integrated 2 www.maximintegrated.com