Compact 150 Watt Enclosed Switching Power Supplies m k 1 5 0 s s e r i e s
Universal 88-264VAC Auto Range Input
Compact Footprint
High Efficiency
Regulated Outputs
3000V Isolation
Built in EMI Filter
3.5W x 6L x 1.75H
model Number Output Voltage Output Amps (max) Ripple/Noise pp,typ
MK150S-5 5 VDC 30 100mv
MK150S-12 12 VDC 12.5 100mv
MK150S-15 15 VDC 10 100mv
MK150S-24 24 VDC 6 100mv
Order On-Line!
astrodyne.com 300 myles standish Blvd., Taunton, mA 02780
WWW.AsTRODYNE.COm
Ph: 1-800-823-8082 Fax: 508-823-8181Compact 150 Watt Enclosed Switching Power Supplies m k 1 5 0 s s e r i e s
INPUT sPECIFICATIONs ENVIRONmENTAL sPECIFICATIONs
Input Voltage Range 88-132/176-264 VAC Oper. Temperature 0 to +60C
Auto Voltage Select (See Derate Curve)
Frequency Range 47-63 Hz Storage Temperature -25 to +85C *
Inrush Current, typ: 20A @ 100VAC * Relative Humidity 10% to 90%, non-cond *
40A @ 200VAC * EMI (Designed to Meet) EN55011, Class B
MTBF 100,000 Hrs
Mil Std 217, 25C
OUTPUT sPECIFICATIONs
Voltage and Current See Selection Chart
PHYsICAL sPECIFICATIONs
Line/Load Regulation (10%-FL) 0.5%, typ
Voltage Tolerance 1%, typ Size 6 x 3.5 x 1.75
DC Voltage Adjust (typ) 6%, typ Construction Enclosed
Temperature Coefficient 0.03%/C Weight 1.37 lb, (630g)
Ripple/Noise 100mV, typ
Over Voltage Protection 130%, Latching, Re-power *
Short Circuit Protection 160%, Indefinite
Hold Up Time 20mS, typ (Nom I/P, FL)
Turn On Time 1.0 sec, typ
Rise Time 20 msec, typ
Over/Under Shoot < 10% of FS
GENERAL sPECIFICATIONs
Isolation I/P-O/P: 3000VAC
I/P-Ground: 1500VAC
O/P-Ground: 500 VAC
Efficiency 78%, typ
Switching Frequency 100Khz, (fixed, typical)
Safety EN60950, IEC60950
UL60950
All specifications are typical at nominal input, full load, and 25C unless other-
wise noted Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
* These are stress ratings. Exposure of the devices to any of these conditions
in hazardous environments, nuclear controls systems, or other
may adversely affect long term reliability. Proper operation under conditions
mission-critical applications.
other than the standard operating conditions is neither warranteed nor implied.
300 myles standish Blvd., Taunton, mA 02780
WWW.AsTRODYNE.COm
Ph: 1-800-823-8082 Fax: 508-823-8181