20 June 2013 Page 1 FEATURES 260W Open Frame Power Supply SP-250 Series 9VDC to 58VDC in a 1VDC increments Active Power Factor Correction Short Circuit, Over Load and Over Voltage Protection Optional Over Temperature Protection UL/cUL EN 60950 2nd Edition CE Compliant 1U Height RoHS Compliant SPECIFICATION Model SP-250-09-B SP-250-12-B SP-250-20-B SP-250-24-B SP-250-48-B SP-250-58-B Voltage (1) 9V 12V 20V 24V 48V 4.5A Current Range 0 ~ 20A 0 ~ 21.67A 0 ~ 13A 0 ~ 10.83A 0 ~ 5.42A 0 ~ 4.5A Rated Power 180W 260W 260W 260W 260W 260W Ripple & Noise 1% Pk to Pk (Max) (2) Voltage Adjustment 10% Range Voltage 5% Tolerance Line Regulation 0.5% Load Regulation 1% Setup, Rise Time All output shall reach their steady state values within 3 Sec. of turn on Holdup Time 16mS min. Voltage 90V ~ 264VAC Frequency 47Hz / 63Hz Efficiency (Typ. 115V 75% 85% 85% 85% 85% 85% AC) AC Current (max.) 4.0A 120VAC Inrush Current (max.) Will not exceed 30A / 115VAC, Cold Start, 25C Leakage Current <300 uA 110-130 % rated output power Over Current Hiccup mode, recovers automatically after fault condition is removed Short Circuit Hiccup mode, recovers automatically after fault condition is removed 110% ~ 150% rated output voltage Over Voltage Hiccup mode, recovers automatically after fault condition is removed Operational 0C ~ 50C with 290 LFM forced air-cooling and or 80 Watts convection cooled. Temperature Range Storage - 40 ~ +80C Operational 20 ~ 90% RH non-condensing Working Humidity Storage 5 ~ 95% R.H Temperature Coefficient 0.05%/C typical on all outputs Vibration 3G, 10-25Hz, 15min. Per cycle for each axis (X, Y, Z) Autec Power Systems Tel: (805)522-0888 www.autec.com 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 Environmental Conditions Protections Input Requirements Output R 20 June 2013 Page 2 Model SP-250-09-B SP-250-12-B SP-250-20-B SP-250-24-B SP-250-48-B SP-250-58-B Safety UL (60950-1:2001) , cUL, DEMKO and CB Standards Withstand I/P - O/P: 3KVAC (4242 DC), 10mA for 1 minute Voltage Isolation I/P - O/P, I/P - case: 10M Ohms / 500VDC Resistance EMI Conduction EN55022 , FCC Class B & Radiation EMS EN61204, EN61000-3-2, EN61000-3-3 Immunity MTBF 30K HRS Compliance: MIL-HDBK-217F Dimension 127*83.82*38.1 (mm) - 5.0*3.3*1.5 (inch) (L*W*H) Weight 0.18kg - 0.40Lb PIN ASSIGNMENT SHIPPING SPECIFICATIONS AC DC Series UNITSP PER CARTON CARTON WEIGHT Connector SP-250 Input Output 20.0 12.34 Kgs 27.21 Lbs Line +V PIN 1 PIN 2 NC +V INDIVIDUL BOX WIDTH LENGTH HEIGHT PIN 3 Neutral +V DIEMENSION Series Inch 14.00 15.00 10.00 PIN 4 NC +V MM 355.6 381.0 254.0 SP-250 PIN 5 Ground +V PIN 6 -V PIN 7 -V PIN 8 -V PIN 9 -V PIN 10 -V +S (remote Sense) PIN 11 PIN 12 -S Connector Molex 26-60-4050 Molex 26-60-4120 Autec Power Systems Tel: (805)522-0888 www.autec.com 667 E Cochran St, Simi Valley, CA93065 Fax: (805)522-8777 Others Safety & EMC