CT Series DIN W48H48mm, W72H36mm, W72H72mm counter/timer Upgrade Upgraded functions Available to set 6 digits(0.00001 to 999999) prescale value (4digit : 0.001 to 9999) Built-in Modbus communication function(Communication model) Available to set the One-Shot output time in 10ms. (0.01sec. to 99.99sec.) Increase contact capacity to 5A(CTS, CTM Series) Available to set Count Start Point.(Initial value) Improved to select memory protection function in the indicator Added BATCH counter function(CTM Series) Added Counter Up-1 / Up-2 / Down-1 / Down-2 input modes Added Counter TOTAL / HOLD operation modes in the indicator Added Timer TOTAL / HOLD / On Time Display operation modes in the indicator Added Timer INT2 / NFD / NFD.1 / INTG output modes Added Timer range 999.999s / 9999m59 / 99999.9h Please read Caution for your safety in operation manual before using. DAQMaster(integrated device management program) DAQMaster is a integrated device management program for convenient management of parameters and multiple device data monitoring. < DAQMaster screen > Visit our website (www.autonics.com) to download user manual and integrated device management program. Item Minimum requirements IBM PC compatible computer with Intel Pentium System or above Operating system Microsoft Windows 98/NT/XP/Vista/7 Memory 256MB or more Hard disk More than 1GB of free hard disk space VGA 1024768 or higher resolution display Others RS-232 serial port(9-pin), USB port Ordering information CT 6 M - 2P 4 T A shaded ( ) part is upgraded or added function. Communication No mark None T RS 485 Power supply 4 100-240VAC 50/60 2 24VAC 50/60 / 24-48VDC 2P Dual preset Output 1P Single preset I Indicator S DIN W48H48mm Size Y DIN W72H36 mm M DIN W72H72mm Digit 4 9999(4digit) 4digit type does not exist 6 999999(6digit) in the indicator type. Item CT Counter/Timer J-8Programmable Counter/Timer (A) Specifications Photo electric Series CTS CTY CTM sensor Digit 4 6 6 6 (B) Dual Preset CT4S-2P CT6S-2P CT6Y-2P CT6M-2P Fiber optic Model Single Preset CT4S-1P CT6S-1P CT6Y-1P CT6M-1P sensor Single Preset - CT6S-1 CT6Y-1 CT6M-1 Single Preset 11mm 10mm 10mm 13mm Digit (C) Door/Area Size Single Preset 8 7 7 9 mm mm mm mm sensor Single Preset 100-240VAC 50/60Hz Power Supply Single Preset 24VAC 50/60Hz / 24-48VDC (D) Proximity Allowable voltage range 90 to 110% of rated voltage(AC Power type) sensor Single Preset Max. 12VA Power consumption Single Preset AC: Max. 10VA / DC: Max. 8W (E) INA/INB Max. counting speed Selectable 1cps / 30cps / 1kcps / 5kcps / 10kcps Pressure sensor Counter Reset signal : Selectable 1ms, 20ms Min. input INA, INH, RESET, INHIBIT, BATCH signal width Timer INA, INB RESET : Selectable 1ms, 20ms RESET : Selectable 1ms, 20ms (F) Rotary Selectable voltage input or No-voltage input encoder Input Voltage input Input impedance is 5.4k, H level : 5-30VDC, L level : 0-2VDC No-voltage input Short-circuit impedance : Max. 1k, Residual voltage : Max. 2VDC (G) One-shot output Count, timer : Selectable 0.01s to 99.99s Connector/ Socket Contact Dual preset : SPST(1a) 2EA Dual preset : SPST(1a) 1EA, SPDT(1c) 1EA With- output Single preset : SPDT(1c) 1EA Single preset : SPDT(1c) 1EA out (H) Solid state Dual preset : 1NPN open collector Dual preset:3NPN open collector com. Temp. output Single preset : 1NPN open collector Single preset:2NPN open collector controller Contact Dual preset : SPST(1a)2EA Dual preset: SPST(1a), SPDT(1c) With- output Single preset : SPDT(1c)1EA Single preset: SPDT(1c) (I) Control out SSR/ output Solid state Dual preset: - Dual preset:2NPN open collector Power com. - controller output Single preset:1NPN open collector Single preset:2NPN open collector Contact 250VAC 5A resistive load 250VAC 3A resistive load 250VAC 5A resistive load With- output (J) out Counter Solid state com. 30VDC Max. 100mA Max. output External sensor power 12VDC 10%, 100mA Max. (K) Timer Memory retention 10years(When using non-volatile semiconductor memory type) Repeat error SET error (L) Power ON Start : Max. 0.01% 0.05 sec Timer Panel Signal Start : Max. 0.01% 0.03 sec Voltage error meter Temperature error Insulation resistance Min. 100M(500VDC Megger) (M) Tacho/ Dielectric strength 2,000VAC 50/60Hz for 1minute Speed/ Pulse meter Noise strength (AC Power) 2kV the square wave noise(pulse width:1) by the noise simulator Mechanical 0.75mm amplitude at frequency of 10 to 55(for 1 min.)Hz in each of X, Y, Z directions for 1 hour (N) Vibration Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 minutes Display unit Mechanical 300m/s(approx. 30G) in each of X, Y, Z directions for 3 times Shock Malfunction 100m/s(approx. 10G) in each of X, Y, Z directions for 3 times (O) Mechanical Min. 10,000,000 operations Relay Sensor Life cycle controller Electrical Min. 100,000 operations Protection IP65(Front panel only) (P) Ambient Switching -10 to 55, storage : -25 to 65 mode power temperature supply Environment Ambient 35 to 85%RH, storage : 35 to 85%RH (Q) humidity Stepper motor& Approval Driver&Controller Unit weight Approx. 159g Approx. 149g Approx. 253g (R) Graphic/ Environment resistance is rated at no freezing or condensation. Logic panel Communication specification (S) Field network Protocol Modbus RTU(16bit CRC) device Connection method RS485 Application standard Compliance with EIA RS485 (T) Number of connections 31, it is available to set address 1 to 127 Software Communication method Half Duplex Synchronous method Asynchronous (U) Communication distance within max. 800meter Other Communication speed 2,400/4,800/9,600/19,200/38,400bps(Factory default : 9,600bps) Response waiting time 5 to 99ms(Factory default : 20ms) Start bit 1bit(Fixed) Data bit 8bits(Fixed) Parity bit None, Even, Odd(Factory default : None) Stop bit 1, 2bit(Factory default : 2bit) J-9