The ABC601 Series of industrial and medical AC-DC power supplies provides up to 600 W of regulated output power through wide input voltage range 85 305 VAC in single outputs of 24, 28, 36 or 48 VDC. The ABC601 Series comes in two packages, U-frame chassis or enclosed with a front mounted fan, offering 12 and 5 VSB standby outputs and a full set of protection features. The ABC601 Series features a built-in I-share circuit for parallel operation between power units to enhance total power. An optional OR-ing external circuit can be provided for N+1 redundant operation. The ABC601 Series complies with the latest international safety standards for IT and medical equipment and displays the CE-Mark for the European Low Voltage Directive (LVD). Universal input voltage range (85 305 VAC) Input surge current limiting 800 W peak power (up to 10 s) High efficiency up to 94% 24, 28, 36 and 48 VDC standard output voltages Low stand-by consumption (<0.35 W) Active PFC, EN 61000-3-2 compliant (Class C, >25% load) Low earth / touch leakage current Fan speed control circuit Over temperature, OV, OC and SC protections. Stand by +5 V, 1.5 A and auxiliary / fan 12 VDC, 1 A outputs Built-in current share signal for parallel operation Remote On / Off signal Power good and remote sense signals Medical safety approval to IEC 60601-1, 2x MoPP protection grade BF appliances compatible IEC 60601-1-2 4th edition EMC compliant IEC 62368-1 standards for Audio Video & IT equipment LED lighting approval to UL 8750 RoHS 3 compliant (Directive EU 2015/863) Video Wall Display and SSL Lighting Industrial Process Control and Automation Telecommunications Laboratory / Analysis Equipment Test and Measurement Equipment Medical Applications 2 ABC601 Series INPUT VOLTAGE NOM. OUTPUT MAX. OUTPUT MAX. OUTPUT MODEL NUMBER PACKAGE & COOLING RANGE VOLTAGE POWER CURRENT DIMENSIONS VAC VDC W A Enclosed 107.0 x 206.0 x 41.0 mm ABC601-1T24-S 85 - 305 24 600 25 Front Mounted Fan 4.21 x 8.11 x 1.6 in U-Chassis 107.0 x 178.5 x 41.0 mm ABC601-1T24 85 - 305 24 600 25 Convection / Forced Air 4.21 x 7.03 x 1.61 in Enclosed 107.0 x 206.0 x 41.0 mm ABC601-1T28-S 85 - 305 28 600 21.4 Front Mounted Fan 4.21 x 8.11 x 1.6 in U-Chassis 107.0 x 178.5 x 41.0 mm ABC601-1T28 85 - 305 28 600 21.4 Convection / Forced Air 4.21 x 7.03 x 1.61 in Enclosed 107.0 x 206.0 x 41.0 mm ABC601-1T36-S 85 - 305 36 600 16.7 Front Mounted Fan 4.21 x 8.11 x 1.6 in U-Chassis 107.0 x 178.5 x 41.0 mm ABC601-1T36 85 - 305 36 600 16.7 Convection / Forced Air 4.21 x 7.03 x 1.61 in Enclosed 107.0 x 206.0 x 41.0 mm ABC601-1T48-S 85 - 305 48 600 12.5 Front Mounted Fan 4.21 x 8.11 x 1.6 in U-Chassis 107.0 x 178.5 x 41.0 mm ABC601-1T48 85 - 305 48 600 12.5 Convection / Forced Air 4.21 x 7.03 x 1.61 in PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT AC Input Voltage PS starts and operates at 85 V at all load conditions 85 100-277 305 V AC RMS DC Input Voltage 170 - 300 V DC 440 Hz with reduced PFC and output power rating. Input Frequency 47 50/60 440 Hz Consult factory for details. RMS at 180 V , maximum load, 50 / 60 Hz 4.0 AC Input Current - - A RMS at 85 V , maximum load, 50 / 60 Hz 8.5 AC 115 V - - 20 AC Inrush Current Cold start, 25 C ambient, full load A 230 V - - 30 AC Fusing High breaking, 10 A, 250 V on each AC lines. - - 10 A 20% rated load 89 - - At 115 V 50% rated load 93 - - AC 100% rated load 92 - - Efficiency % 20% rated load 90 - - At 230 / 277 V 50% rated load 94 - - AC 100% rated load 94 - - Power on, 115 V , no load - - 5 AC Input Power Consumption Power on, 230 V , no load - - 4 W AC Stand by, 115, 230 V , no load - - 0.35 AC Power Factor From 50 to 100% of rated load, 230, 115 V , 50 / 60 Hz input voltages. 0.90 - - - AC THDi From 50 to 100% rated load, 115, 230, 277 V 50 / 60 Hz. - - 20 % AC Complies with EN 61000-3-2 at 230 V , 50/60 Hz, Class A, D. AC Harmonic Current Complies with EN 61000-3-2 Class C at 230 V , 50/60 Hz, >150 W load. AC Fluctuations and Flicker Complies with EN 61000-3-3 at nominal voltages and full load. Normal conditions 115 V , 60 Hz - 130 - RMS Earth Leakage Current 230 V , 50 Hz - 240 - A RMS 264 V , 60 Hz (worst case) - - 400 RMS 277 V , 60 Hz - - - RMS 264 V , 60 Hz RMS Touch Leakage Current Normal Condition (NC) - - 100 A Single Fault Condition (SFC) - - 500 264 V , 60 Hz RMS Patient Leakage Current Normal Condition (NC) - - 100 A Single Fault Condition (SFC) - - 500 tech.support psbel.com