The ABC800 Series of open frame power supplies feature a wide universal AC input range of 85 264 VAC, offering up to 800 W of output power with forced air cooling in a compact footprint, with a variety of single output voltages. The high efficiency and high power density of the ABC800 series ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications. 5 x 8.5 x 1.61 Inch Form Factor (127 x 216 x 41 mm) Convection or Forced Air Cooling Universal input Current Sharing Option Peak Power Capability 5 VDC Stand by output 12 V Fan output Power Good / Power Fail Signal Suitable in POE applications Lesser than 1U high High voltage output range up to 58 VDC N+1 redundant power supply Single wire current sharing Built in OR-ing diode / FET (- R suffix) Instrumentation Renewable Energy Lighting Test and Measurement Industrial Applications Robotics Applied Computing Wireless Communication 2 ABC800 Series ABC800-1T12 U-Channel 25 A 33.33 A ABC800-1T12-H 12 V U-Channel + Slotted Cover 17.5 A 31.25 A 0.0 A 2% ABC800-1T12-P U-Channel + Plain Cover 15 A 31.25 A ABC800-1T15 U-Channel 25 A 33.33 A ABC800-1T15-H 15 V U-Channel + Slotted Cover 17.5 A 31.25 A 0.0 A 2% ABC800-1T15-P U-Channel + Plain Cover 15 A 31.25 A ABC800-1T24 U-Channel 25 A 33.33 A ABC800-1T24-H 24 V U-Channel + Slotted Cover 17.5 A 31.25 A 0.0 A 2% ABC800-1T24-P U-Channel + Plain Cover 15 A 31.25 A ABC800-1T30 U-Channel 20 A 26.66 A ABC800-1T30-H 30 V U-Channel + Slotted Cover 14 A 25 A 0.0 A 2% ABC800-1T30-P U-Channel + Plain Cover 12 A 25 A ABC800-1T48 U-Channel 12.5 A 16.66 A ABC800-1T48-H 48 V U-Channel + Slotted Cover 8.75 A 15.625 A 0.0 A 2% ABC800-1T48-P U-Channel + Plain Cover 7.5 A 15.625 A ABC800-1T58 U-Channel 10.34 A 13.78 A ABC800-1T58-H 58 V U-Channel + Slotted Cover 7.25 A 12.93 A 0.0 A 2% ABC800-1T58-P U-Channel + Plain Cover 6.2 A 12.93 A 1 To order product without the redundancy diode option please add the suffix-Sxxx to your required part number. Please contact the factory for availability. 2 For Ripple measurement minimum output power requirement is 25 W. Ripple is peak to peak with 20 MHz bandwidth and 10 F (Electrolytic capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. Specifications are for nominal input voltage, 25C unless otherwise stated. Input Voltage Universal 85 264 VAC / 120 390 VDC Input Frequency 47 63 Hz 120 VAC: 8.00 A max. Input Current 240 VAC: 3.64 A max. Input Protection In Live & Neutral both F16 A / 250 V Over entire input range with main output kept off using No Load Power 3 W typ. Remote ON/OFF Inrush Current 240 VAC: 25 A max. Leakage Current 240 VAC / 50 Hz 400 A Touch Current: < 100 A 120 VAC: 0.98 Power Factor 240 VAC: 0.95 PFC converter: Variable 85 kHz typical Switching Frequency Resonant converter: Variable 100 kHz typical North America Asia-Pacific Europe, Middle East +86 755 298 85888 +353 61 225 977 +1 408 785 5200 2020 Bel Power Solutions & Protection BCD.01018 B