The ABC1200 / ABE1200 Series of AC-DC power supplies provide a steady 1200 W of regulated DC power through 180-305 VAC and 1000 W through 85-137 VAC input voltage ranges in a single output of 24 or 48 VDC, offering 12 and 5 VSB standby outputs and a full set of protection features. The ABC1200 / ABE1200 Series is available in three compact 1U height compatible packages. One is enclosed with a built-in front mounted pair of fans and two (available only 24 V variant), U-shaped chassis with or without protective cover, to facilitate system integration. The ABC1200 / ABE1200 Series supports digital power management over the Power Management Bus communications protocol. Multiple units may be connected in parallel for redundancy and / or higher power, enabled with the internal OR-ing and current sharing functions. The ABC1200 / ABE1200 Series complies with the latest international safety standards and displays the CE-Mark for the European Low Voltage Directive (LVD). Universal input voltage range (85 305 VAC) Input inrush current limiting 1200 W rated power High efficiency up to 94% Single 24 VDC or 48 VDC output voltages available Active PFC, EN61000-3-2 compliant (Class C, >25% load) Low earth / touch leakage current Fan speed control function 800 LFM airflow for ABC1200 models Over temperature, OV, OC and SC protections +12 V, 0.5 A +5 V, 1 A Stand by outputs Built-in current sharing and OR-ing for parallel operation and N+1 redundancy Remote On / Off signal Power good and remote sense signals Power Management Bus communication protocol supported Safety approvals to IEC/EN/UL 62368-1, IEC 60950-1 LED lighting approval to UL 8750 Video Wall Display, Entertainment Lighting LED Lighting Engine Industrial Control Systems Industrial Laser Applications 2 ABC1200 / ABE1200 Series INPUT VOLTAGE NOM. OUTPUT MAX. OUTPUT MAX. OUTPUT PACKAGE & MODEL NUMBER RANGE VOLTAGE POWER CURRENT DIMENSIONS COOLING VAC VDC W A U-chassis, 101.6 x 234.0 x 41.0 mm ABC1200-1T24-UCF 85 - 305 24 1200 50 external air flow 4.00 x 9.21 x 1.61 in Protective cover, 101.6 x 234.7 x 41.0 mm ABC1200-1T24-PCF 85 - 305 24 1200 50 external air flow 4.00 x 9.24 x 1.61 in Enclosed, 101.6 x 264.1 x 41.0 mm ABE1200-1T24 85 - 305 24 1200 50 front mounted fan 4.00 x 10.4 x 1.61 in Enclosed, 101.6 x 264.1 x 41.0 mm ABE1200-1T48 85 - 305 48 1200 25 front mounted fan 4.00 x 10.4 x 1.61 in PARAMETER DESCRIPTION / CONDITION MIN NOM MAX UNIT PS starts at 85 V at all load conditions AC Operating input voltage range 85 100-277 305 V RMS AC Input Voltage ABC1200 / ABE1200 Series is designed to operate with a square or trapezoidal input voltage wave form (i.e. from UPS) Built in fuses safety certified up to 250 V . Operating the 1200 Series DC DC Input Voltage 120 - 300 VDC above that limit up to 300 V , does require an external fuse protection * DC Input Frequency 400 Hz (max 440 Hz) operation over 85 137 VAC input range 47 50/60 63 Hz At 180 V , maximum load, 50 / 60 Hz 8.0 AC ARMS At 85 VAC, 1000 W load, 50 / 60 Hz 14.5 Input Current - - 163 VDC, maximum load 9.0 A 120 V , 1000 W 10.0 DC At power-on asserted Cold start, 25 C ambient, full load Inrush Current Any point of the AC input sine 230 VAC - - 30 A 277 V - - 50 AC Fusing High breaking, 16 / 20 A, 277 VAC (250 VDC) on each AC line. - - 16 / 20 A 20% rated load 88 - - At 120 V 50% rated load 92 - - AC 100% rated load 92 - - Efficiency % 20% rated load 90 - - At 230 VAC 50% rated load 93 - - 100% rated load 94 - - At power on, no load, 100-277 V range (ABE1200-1T24 / -1T48) - 7.0 - AC Input Power Consumption At power on, no load, 100-277 VAC range (ABC1200-1T24-UCF / -PCF) - 6 - W Stand by, no load, nominal 100-277 VAC range - 4.0 - Power Factor Any nominal input line voltage, 50/60 Hz, from 50 to 100% maximum load 0.95 - - - THDi From 50 to 100% rated load, 100-277 V ,50/60 Hz. - - 20 % AC Complies with EN 61000-3-2 at 230 VAC, 50/60 Hz, Class A, D. Harmonic Current Complies with EN 61000-3-2 Class C at 230 VAC, 50/60 Hz, >300 W load. Fluctuations and Flicker Complies with EN 61000-3-3 at nominal voltages and full load. Normal conditions 115 VRMS, 60 Hz - 130 - Earth Leakage Current A 230 VRMS, 50 Hz - 240 - 264 V , 60 Hz (worst case) - - 400 RMS 264 V , 60 Hz RMS Touch Leakage Current Normal Condition (NC) - - 100 A Single Fault Condition (SFC) - - 500 * Suggested fuse SIBA 5012434.16 and fuse holder SIBA 5105805.1 tech.support psbel.com