The FCP400-12G is highly-efficient AC-DC power supply, with one high current output and an additional standby output, which can be used in a wide range of applications. Active current share along with internal ORing FET allow the FCP400 s to be also used in redundant, hot-swap applications. Model meet international safety standards and display the CE Mark for the low Voltage Directive. RoHS lead free solder Certified to efficiency 80plus platinum Wide input voltage range 90-264 VAC Two outputs (one high current output) Low conducted and radiated EMI (EN 55022 class B) Telecommunication Equipment Safety approved to the latest editions of the following standards: CSA/UL60950-1, EN60950-1 and IEC60950-1 High density design 4 x 1.58 x 8.5 cassette Highly-efficient topology 2 I C interface Overtemperature, output overvoltage, and output overcurrent protection Supervisory signaling Included ORing FET for true redundant operation North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 tech.support psbel.com 2015 Bel Power Solutions, Inc. BCD.00141 AC FCP400-12G Output 1 Output 2 Input Voltage Rated Power Model V I V I o nom o max o nom o max VAC W VDC ADC VDC ADC FCP400-12G* 90-264 12 33.3 12 0.7 408 * Suffix G added to the part number means the product is RoHS compliant for all 6 substances Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability, and cause permanent damage to the converter. PARAMETER CONDITIONS / DESCRIPTION MIN MAX UNITS Continuous 264 VAC Input Voltage Transient, 60 ms 300 VAC Ambient Operating Temperature 0 55 C V -V , I , cooling by internal fan i min i max o nom Storage Temperature Non-operational -40 85 C All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage 90 115/230 264 VAC Turn-On Input Voltage Ramping up 70 - 90 VAC Turn-Off Input Voltage Ramping down 70 - 90 VAC Input Frequency 47 50/60 63 Hz Inrush Current Limitation 115/230 VAC 20/27 A Power Factor V , I 0.96 i nom o nom Efficiency V = 230 VAC, I 90 % i o nom All specifications apply over specified input voltage, output load, and temperature range unless otherwise noted. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Output Voltage Setpoint Accuracy V = 230 VAC, I 16.6 ADC, T = 25 C -0.01 0.01 VDC i o1 C Output Current V1 0 33.3 33.3 ADC Output Current V2 0 0.7 0.7 Static Line Regulation V1 Vi min-Vi max, Vi nom, 0-100% Io nom -0.06 0.06 VDC Static Load Regulation V1 V -V , V , 0-100% I -0.1 0.1 VDC i min i max i nom o nom (Droop Characteristic) Hold-Up Time Starting at Vi = 230 VAC, Po nom 20 ms Load change 5A to 16A, 16A to 27A and back Dynamic Load Regulation voltage deviation -0.24 0.24 VDC recovery time 400 s Start-Up Time Vi nom, Io nom 1.5 s Output Voltage Ripple and Noise Vi nom, Io nom, 20 MHz bandwidth 120 mVpp +1.866.513.2839 tech.support psbel.com 2015 Bel Power Solutions, Inc. BCD.00141 AC