FNP1500/1800 Front-Ends & FNR-3 Power Shelves Data Sheet Features RoHS compliant for all six substances 3 High density front-ends 15.2 to 18.3 W/in Wide input voltage range 85 to 264 VAC 12 V standby voltage, 1A per front-end Highly efficient topology reduces operating costs FNP1500/1800 front-ends have 2 I C interface status and control front-mounted AC input receptacles. 2 I C voltage and current limit setting Analog output voltage setting Overtemperature, output overvoltage, and output overcurrent protection ORing circuits for true redundant operation: Applications V : ORing FETs V : ORing Diodes o1 o2 Telecommunications Status LEDs: AC OK, DC OK, and Fan Fail/Overtemperature Fail Data communications Servers Distributed power FNR-3 Power Shelf FNR-3 shelves provide up to 5400 watts in a 19 rack. (See the Rack section for power shelf details.) Description The FNP1500/1800 front-ends are power-factor-corrected (PFC) which (depending on model type) provide a 12 VDC or 48 VDC (1500 or 1800 watt) output, and can be used in hot-swap redundant systems. Their very small dimensions allow configuration of up to three units in a 1U rack. The FNP front-ends have a front-mounted AC receptacle. The highly efficient thermal design with internal-fan cooling permits their use over wide temperature ranges and provides very high reliability. 2 2 Status information is provided with front panel LEDs, logic signals, and via an I C management interface. In addition, the I C bus can enable the power supply, set high fan speed, adjust the output voltage, and set the output current limit. The FNP1500/1800 s meet international safety standards and display the CE-Mark for the European Low Voltage Directive (LVD). FNR-3-12G and FNR-3-48G power-shelf solutions provide rectification, system management, and power distribution, while maintaining high reliability and offering flexibility for future expansion. The power shelves can be configured with up to three hot- swappable 1500 or 1800-watt AC-DC front-ends. BCD.00247 Rev. AA, 07-Nov-12 Page 1 of 18 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelves Data Sheet Model Selection Output 1 Output 2 Input voltage Rated power Compatible Model VAC V I V I 2 o1 nom o1 max o2 nom o2 max 1 W Shelf auto selected VDC ADC VDC ADC 108 264 12 129 11.64V 12 1 1512 FNP1500-12G FNR-3-12G 85 105 12 101.8 11.78A 12 1 1212 105 264 48 32.2 12 1 1512 FNP1500-48G FNR-3-48G 85 105 48 25.4 12 1 1212 180 264 48 39.2 12 1 1812 FNP1800-48G 105 180 48 32.2 12 1 1512 FNR-3-48G 85 105 48 25.4 12 1 1212 1 The available output power is automatically adjusted depending on the input voltage. 2 1U standard racks are available from Power-One. See the Rack (Power Shelf) section of this data sheet for configurations and details. Absolute Maximum Ratings Stress in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-term reliability, or cause permanent damage to the converter. Parameter Conditions/Description Min Max Unit Input voltage Continuous 264 VAC Transient, 60 ms max. 300 VAC Operating ambient temperature V -V , I , cooling by internal fan i min i max o nom 100 % load 0 50 C 50 % load 0 70 C Storage temperature Non-Operating -40 85 C Environmental, Mechanical, & Reliability Specifications Parameter Conditions/Description Min Nom Max Unit Altitude Operating 10 k ASL Ft. Non-Operating 40 k ASL Ft. Relative humidity, non-condensing Operating 10 90 % RH Storage 5 95 % RH Temperature coefficient 0 C to 70 C (after 15 min warm-up) 0.02 %/K Shock IEC/EN 60068-2-27, 11 ms 40 g pk Sinusoidal vibration IEC/EN 60068-2-6 2-8 Hz 7.5 mil 8-200 Hz 2 g pk 200-500 Hz 4 g pk Random vibration 10-2000 Hz 6.15 g rms MTBF Calculated per Bellcore (SR-332, Issue 1): GB 25 C 230 kh GB 25 C (FNP1500-12G) TBD kh Demonstrated 250 kh BCD.00247 Rev. AA, 07-Nov-12 Page 2 of 18 www.power-one.com