The FNP600/850/1000 power factor corrected (PFC) front ends provide (depending on model) either a 12 VDC or a 48 VDC output for telecom, datacom, and other distributed power applications. Their small 1U by 2U size allows for configurations of either height in hot- swap redundant systems while their internal fan and cooling design permits wide use with reliable operation. Status is provided with front panel LEDs, logic signals, 2 and via the I C management interface bus. In addition, 2 the I C bus can enable the power supply, control fan speed, and on the 12 VDC models it allows for adjusting the output voltage from 7 to 12 VDC. This powerful feature allows the same power supply to be used in various applications where bus voltages driving isolated dc-dc converters and POL regulators may be different. Also, the FNP850-12R is uniquely designed with airflow from the rear of the power supply to the front. This airflow direction supports those critical applications where space limitations and/or higher ambient temperatures near the rear of the rack system, prohibit RoHS lead free solder and lead solder exempted the discharge of higher temperature airflow from regular products are available front-to-rear cooled power supplies. 3 High density front-ends 10.5 to 16.1 W/in Universal input voltage range (90-264 VAC) with PFC The FNP600/850/1000 s meet international safety 1U or 2U height configurations requirements and are CE marked to the Low Voltage Droop current share with ORing FETs Directive (LVD). 2 I C interface status and control Standby voltage of 12 VDC 0.5 A Overtemperature, overload, and overvoltage protection Telecom Status LEDs: AC OK, DC OK, Overtemperature Datacom FNP850-12 model has airflow direction from Distributed Power Systems front-to-rear or from rear-to-front (-12R model) ON/OFF Enable switch - shuts OFF Vo1 Vaux and fan are operational. North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 tech.support psbel.com 2015 Bel Power Solutions, Inc. BCD20034-G AE FNP600/850/1000 NOMINAL MAXIMUM ADJUSTMENT LINE LOAD RIPPLE & OUTPUT OUTPUT COMPATIBLE MODEL RANGE REGULATION REGULATION NOISE VOLTAGE CURRENT SHELF 2 3 (VDC) (%) (%) pk-pk % 1 (VDC) (Amps) 12 7 to 12 51 0.17 6 1 FNP600-12 FNR-5-12 12 (Standby) N/A 0.5 8 8 1 12 7 to 12 73 0.17 6 1 FNP850-12 FNR-5-12 12 (Standby) N/A 0.5 8 8 1 12 7 to 12 73 0.17 6 1 4 FNP850-12R FNR-5-12 12 (Standby) N/A 0.5 8 8 1 48 44 to 50.5 12.6 0.17 6 1 FNP600-48 FNR-5-48 12 (Standby) N/A 0.5 8 8 1 48 44 to 50.5 21 0.17 6 1 FNP1000-48 FNR-5-48 12 (Standby) N/A 0.5 8 8 1 1 Models with 5V and 3.3V standby voltages are also available. (Contact factory.) 2 Primary 12V and 48V outputs have built-in droop regulation. 3 Maximum peak-to-peak noise expressed as a percentage of output voltage 20 MHz bandwidth. 4 FNP850-12R model has airflow from rear to front. Options Suffixes to Add to Part Number RoHS lead solder exemption No RoHS suffix character required. RoHS compliant for all 6 substances Add as the last character of the part number. PARAMETER CONDITIONS/DESCRIPTION MIN. NOM. MAX. UNITS AC Input Voltage Single-phase continuous input range. 90 264 VAC Input Frequency AC input. 47 63 Hz 1 Hold-up Time After last AC line peak at full power. At 115 VAC 20 ms Input Current At full-rated load. At 90 VAC 14 A rms Inrush Surge Current Internally limited. Vin = 230 VAC, T = 25 C 34 A pk Power Factor Per EN61000-3-2 0.97 W/VA 1 FNP1000-48 model has a hold-up time of 16 ms PARAMETER CONDITIONS/DESCRIPTION MIN. NOM. MAX. UNITS FNP600-48 88 89.5 FNP1000-48 88 89.5 Efficiency: Full rated load at 230 VAC input. % FNP600-12 84 87 FNP850-12 84 87 Minimum Load Minimum loading required to maintain regulation. 0 A FNP1000 1006 Output Power FNP850 856 W FNP600 600 Overshoot Output voltage overshoot at turn-on. 3 % Maximum recovery time to within 1% 12V or 48V output: 400 s of initial set point due to a 50% load Standby output: 2 ms Transient Response change, 1A/s. 12V or 48V output: 2 Maximum deviation: % Standby output: 4 Time required for initial output voltage stabilization after Turn-On Delay 1.5 Sec application of AC input.. Output Regulation See Model Selection table. 866.513.2839 tech.support psbel.com 2015 Bel Power Solutions, Inc. BCD20034-G AE