FXP7000 AC-DC Series Data Sheet Features Three-phase AC input Suitable for 3U or 5U height mounting Single-wire current share or Droop current share Remote voltage adjust and current monitoring Overtemperature, overload, and overvoltage protection LED supply status indicators Current share control for up to 30 units Standard & customized rack adaptors available FXP7000 Front panel selectable-input-range Front and Rear Views The FXP7000 Series of rack-mounted power systems indicator lights on the front panel and a single hot-plug provides AC front-end capability to automatic test connector on the rear. Airflow is from the front through equipment, telecom, data communications, and other the rear. Alarm, monitoring, and control signals are distributed power designs. The pluggable FXP supplies floating from the main output and can be referenced to do not include an output isolation diode and may be the positive or negative output or sense line of the power paralleled up to 210 kW of total output power. These supply. The output is floating with respect to the chassis supplies provide excellent protection against input and may be used as a positive or negative polarity voltage transients. supply. Access to interfaces for remote sensing, remote voltage The FXP7000 Series meets international safety adjust, current sharing, current monitoring, power supply requirements and is CE Marked to the Low Voltage status, standby voltage and inhibit, as well as power Directive. This series operates on three-phase European connections, is through a connector at the rear of the voltages as well as (up to) 480VAC, delta or wye. supply. The FXP has its fan, handles, voltage adjust, and Hot-Pluggable Model OUTPUT INPUT VOLTAGE RANGE ADJUSTMENT MAXIMUM OUTPUT LINE LOAD INITIAL SETTING MODEL VOLTAGE 3-PHASE (VAC) RANGE CURRENT REGULATION REGULATION (NOTE 1) ACCURACY FXP7000-48-S 48V 180 to 264 or 342 to 528 45.6V to 50.4V 145A 0.15% 0.2% 47.90V to 48.10V NOTES: 1) With Remote Sense connected. Input Specifications PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Input Voltage - AC 3-phase delta low input range, nominal. 200 240 VAC 3-phase delta high input range, nominal. 380 480 Continuous deviation from the above nominals. -10 +10 % Input Current Per phase at full rated load. FXP7000 at 180 VAC: 30 ARMS Inrush Surge Current Internally limited. Vin = 264VAC (one cycle). 25 C: 38 APK Vin = 528VAC (one cycle). 25 C: 38 Input Frequency AC input. 50 60 Hz Hold-up Time After last AC line peak at full power. 208 VAC: 17 ms 400 VAC: 13 Operating Frequency Switching frequency, fixed. 100 kHz Power Factor 0.90 W/VA MCD10162 Rev. 1.0, 04-Jun-10 Page 1 of 8 www.power-one.comFXP7000 AC-DC Series Data Sheet Output Specifications PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Output Voltage An additional 1.0 Volt is provided to the output terminals to provide for 45.6 48 50.4 V Adjustment Range load lead losses. Output Power Continuous duty rating. 7000 Watts Output Current Continuous duty rating. 145 A Efficiency Full rated load (208Vac). 88 91 % Regulation Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: 0.2 With Remote Sense not connected: 0.75 % Utilizing Droop Current Share: 2.0 Line, Under all specified operating conditions. 0.2 Ripple & Noise Measured at mating connector w/ 0.01F + 10F Tant. 20 MHz BW: 1 % p-p 100 MHz BW: 2 Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Minimum Loads Minimum loading required to maintain regulation. 0 A Transient Response Maximum recovery time, to within 1% of initial set Time: 800 s point due to a 25% load change, 1A/S. Deviation: 3.2 % Turn-On Delay Time required for initial output voltage stabilization after power-up. 3 s Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 100 ms Interface Signals and Protection PARAMETER (NOTE 1,2) DESCRIPTION/CONDITIONS MIN NOM MAX UNITS AC Power Fail Warning Warning provided prior to Vout dropping 5% after loss of AC input. 4 ms Auxiliary Power Output voltage - diode isolated. Inclusive of line, load, and initial tolerances. 11.6 12.0 12.4 V Output current. 500 mA Current Monitor Monitor output current over a compliance range of 0~10V. Normal output: 0.10 mA/A Total error current: 0.5 0 0.5 mA Current Share Static sharing deviation as a percent of full-load rating Active: 5 % for loads >10%. Passive: 10 Input Range Select Status Maximum signal resistance in high input voltage range selection. 0.10 Loss of Phase Warning Warning provided prior to protective reduction in current limit. 500 ms Output Inhibit Voltage required to enable supply (0.5 mA sink). (NOTE 3) 1.0 V Output Interlock Voltage required to enable supply (6 mA sink). (NOTE 3) 1.0 V Output Overload Protection Straight line current limit (above approx. 5V Vout). 149 156 A Output Overload Warning Signal level on overload. 2.2 V Output Short Circuit Protection Occurs on overload when Vout is below approx. 5V. Iavg: 25 90 A May operate in burst-mode. Output Voltage Fault Signal Deviation from adjusted Vout that is considered as a fault. 3 4 5 % Output Voltage Margin Output voltage swing available through Margin pin (analog). 4.8 5.0 5.2 % Overtemperature/ Time between fault warning and shutdown. 100 ms Fan Failure Warning Latching shutdown. Overvoltage Protection Latch style overvoltage protection. 55.2 57.6 60.0 V Power Supply Present Signal Resistance to logic ground upon insertion of supply. 1000 Remote Sense Maximum load lead loss compensation (round trip). 1.0 V NOTES: 1) All logic outputs listed below feature a standard active pull-down output with 0.4V max at 40 mA sink capability, and a 100k pull-up to 5V. 2) In addition to those listed below, signals and front-panel LEDs are provided to indicate: overtemperature/fan fault, AC phase imbalance, output good, interlock open, and supply inhibited. The FXP also provides 4 L E D s indicating output loading. 3) Both signals must be pulled to logic ground for the unit to operate. Enables are 100% redundant internally for applications where redundant inhibit is desirable. Contact factory for additional design details. MCD10162 Rev. 1.0, 04-Jun-10 Page 2 of 8 www.power-one.com