M Series Data Sheet 50 Watt DC-DC and AC-DC Converters Features Extremly wide operating input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47 to 440 Hz RoHS lead-free-solder and lead-solder-exempted products available 5 year warranty for RoHS compliant products with an extended temperature range Class I equipment Input over- and undervoltage lockout 1, 2, or 3 individually isolated outputs up to 72 V Outputs: SELV, no load, overload, short-circuit proof, rectangular current limiting characteristic Adjustable output voltages with remote on/off Immunity according to IEC/EN 61000-4-2, -3, -4, -5, -6 Emissions according to EN 55011/55022 According to EN 45545 and NF-F-16 (Version V107 or later) 111 4.37 3U All PCBs boards coated by protective lacquer 168 Very high reliability 39 6.6 1.54 8TE Battery charger models available Safety-approved to the latest edition of IEC/EN 60950-1 Description and UL/CSA 60950-1 The M Series of DC-DC and AC-DC converters represents a broad and flexible range of power supplies for use in advanced industrial electronic systems. Features include high efficiency, reliability, low output voltage noise and excellent dynamic Full input to output, input to case, output to case, and output to response to load/line changes due to individual regulation of output isolation is provided. each output. The case design allows operation at nominal load up to 71 C The converter inputs are protected against surges and in a free-air ambient temperature. If forced cooling is provided, transients occurring at the source lines. An input over- and the ambient temperature may exceed 71 C but the case undervoltage lockout circuit disables the outputs, if the input temperature should remain below 95 C under all conditions. voltage is outside the specified range. An inrush current limitation prevents circuit breakers and fuses from tripping at A temperature sensor generates an inhibit signal, which switch-on. disables the outputs, when the case temperature T exceeds C the limit. The outputs automatically recover, when the All outputs are open- and short-circuit proof, and are protected temperature drops below the limit. against overvoltages by means of built-in suppressor diodes. The outputs can be inhibited by a logic signal applied to the Various options are available to adapt the converters to connector (pin 2). If the inhibit function is not used, pin 2 should individual applications. be connected to pin 23 to enable the outputs. The converters may either be plugged into a 19 rack system LED indicators display the status of the converter and allow according to IEC 60927-3 or be mounted onto a chassis or a visual monitoring of the system at any time. plate. Table of Contents Page Page Description ............................................................................. 1 Electromagnetic Compatibility (EMC) .................................. 14 Model Selection ..................................................................... 2 Immunity to Environmental Conditions ................................ 16 Functional Description ........................................................... 5 Mechanical Data .................................................................. 17 Electrical Input Data ............................................................... 6 Safety and Installation Instructions ...................................... 18 Electrical Output Data ............................................................ 8 Description of Options ......................................................... 20 Auxiliary Functions ............................................................... 11 Accessories.......................................................................... 26 Copyright 201 8, Bel Power Solutions Inc. All rights reserved. MELCHER BCD20018-G Rev AE1, 16-Apr-2018 Page 1 of 26 The Power Partners.M Series Data Sheet 50 Watt DC-DC and AC-DC Converters than 1000 different model types have been manufactured Model Selection with different input/output configurations and customized Non-standard input/output configurations or special custom specialties. Please consult the company for additional model adaptions are available on request. Table 1 provides an types overview of the basic input and output configurations. More Table 1a: Standard models AM, BM, FM Output 1 Output 2 Output 3 Operating input voltage range and efficiency Options 1 1 1 V I V I V I V V V V V V o nom o nom o nom o nom nom o nom i min i max min i min i max min i min i max min VDC A VDC A VDC A 8 35 VDC % 14 70 VDC % 20 100 VDC % 5.1 8.0 - - - - AM1001-9RG 72 BM1001-9RG 74 FM1001-9RG 74 -7, P 12 4.0 - - - - AM1301-9RG 79 BM1301-9RG 80 FM1301-9RG 80 D0 D9, 3 15 3.4 - - - - AM1501-9RG 79 BM1501-9RG 81 FM1501-9RG 81 V0 V3 24 2.0 - - - - AM1601-9RG 81 BM1601-9RG 83 FM1601-9RG 82 F, A, K, H 48 1.0 - - - - AM1901-9RG 81 BM1901-9RG 83 FM1901-9RG 83 non-G 5.1 4.0 5.1 4.0 - - AM2001-9G - BM2001-9G - - - -7, P 5.1 4.0 24 1.0 - - AM2060-9G - BM2060-9G - - - D0 D9 12 2.0 12 2.0 - - AM2320-9G 77 BM2320-9G 79 FM2320-9G 80 A, K, H 15 1.7 15 1.7 - - AM2540-9G 78 BM2540-9G 80 FM2540-9G 79 non-G 24 1.0 24 1.0 - - AM2660-9G - BM2660-9G - -- 5.1 5.0 12 0.7 12 0.7 AM3020-9G 75 BM3020-9G 76 FM3020-9G 76 -7, P 5.1 5.0 15 0.6 15 0.6 AM3040-9G 75 BM3040-9G 76 FM3040-9G 76 D0 D9, A 5.1 5.0 24 0.35 24 0.35 AM3060-9G - BM3060-9G - - - K, H, non-G Table 1b: Standard models CM, DM, LM Output 1 Output 2 Output 3 Operating input voltage range and efficiency Options 1 1 1 V I V I V I V V V V V V o nom o nom o nom o nom nom o nom i min i max min i min i max min i min i max min VDC A VDC A VDC A 28 140 VDC % 44 220 VDC % 88 372 VDC % 2 85 264 VAC 4 5.1 8.0 - - - - CM1001-9RG 74 DM1001-9RG 74 LM1001-9RG 74 -7, E , P 12 4.0 - - - - CM1301-9RG 80 DM1301-9RG 81 LM1301-9RG 80 D0 D9 3 15 3.4 - - - - CM1501-9RG 82 DM1501-9RG 82 LM1501-9RG 79 V0 V3 24 2.0 - - - - CM1601-9RG 82 DM1601-9RG LM1601-9RG 82 A, K, H 48 1.0 - - - - CM1901-9RG 82 DM1901-9R 83 LM1901-9RG 82 non-G 4 5.1 4.0 5.1 4.0 - - CM2001-9G - DM2001-9G LM2001-9G - -7, E , P 5.1 4.0 24 1.0 - - CM2060-9G - DM2060-9G LM2060-9G - D0 D9 12 2.0 12 2.0 - - CM2320-9G 79 DM2320-9G 80 LM2320-9G 80 A, K, H 15 1.7 15 1.7 - - CM2540-9G 80 DM2540-9G 80 LM2540-9G 79 non-G 24 1.0 24 1.0 - - CM2660-9G - DM2660-9G LM2660-9G 4 5.1 5.0 12 0.7 12 0.7 CM3020-9G 76 DM3020-9G 77 LM3020-9G 74 -7, E , P 5.1 5.0 15 0.6 15 0.6 CM3040-9G 76 DM3040-9G 76 LM3040-9G 73 D0 D9, A 5.1 5.0 24 0.35 24 0.35 CM3060-9G 76 DM3060-9G 76 LM3060-9G - K, H, non-G 1 Min. efficiency at V and I . Typ. values are approx. 2% better. i nom o nom 2 Operating frequency range: 47 440 Hz see Safety and Installation Instructions for >60 Hz 3 Option V0, V2, V3 available only for output 1 = 5.1 V (excludes option D) 4 Option E only available for CM and LM models (not for DM) NFND: Not for new designs. Preferred for new designs MELCHER BCD20018-G Rev AE1, 16-Apr-2018 Page 2 of 26 The Power Partners.