S Series Data Sheet 100 Watt AC-DC and DC-DC Converters Features Input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47-440 Hz 1or 2 isolated outputs up to 48 VDC Class I equipment RoHS lead solder exemption compliant Extremely-wide input voltage range Input over- and undervoltage lockout Efficient input filter and built-in surge and transient suppression circuitry Outputs: SELV, no-load, and short-circuit proof No derating over entire operating temperature range 111 PCBs coated with protective lacquer 4.4 3 U Very high reliability 60 168 2.4 6.6 12 TE Safety according to IEC/EN 60950 Description The S Series AC-DC and DC-DC converters represents a broad The case design allows operation at nominal load up to 71 C in a and flexible range of power supplies for use in advanced free-air ambient temperature. If forced cooling is provided, the electronic systems. Features include high efficiency, high ambient temperature may exceed 71 C, but the case temperature reliability, low output voltage noise and excellent dynamic must remain below 95 C under all conditions. response to load/line changes. LS models can be powered by A temperature sensor generates an inhibit signal, which disables DC or AC with a wide-input frequency range (without PFC). the outputs if the case temperature T exceeds the limit. The c The converter inputs are protected against surges and outputs are automatically re-enabled when the temperature drops transients. An input over- and undervoltage lockout circuitry below the limit. disables the outputs if the input voltage is outside of the Various options are available to adapt the converters to individual specified range. Certain types include an inrush current limiter applications. preventing circuit breakers and fuses from tripping at switch-on. The converters may either be plugged into a 19 rack system All outputs are open- and short-circuit proof and are protected according to IEC 60297-3, or be chassis mounted. They are ideally against overvoltages by means of built-in suppressor diodes. suited for Railway applications. The outputs can be inhibited by a logic signal applied to pin 18 (i). If the inhibit function is not used, pin 18 must be connected Important: For applications requiring compliance with IEC/EN with pin 14 to enable the outputs. 61000-3-2 (harmonic distortion), please use our LS4000 and LS5000 Series with incorporated power factor correction (PFC). LED indicators display the status of the converter and allow for visual monitoring of the system at any time. Full input-to-output, input-to-case, output-to-case and output-to- output isolation is provided. The converters are designed and built according to the international safety standards IEC/EN 60950 and EN50155. They have been approved by the safety agencies TV and UL (for USA and Canada). Table of Contents Page Page Description ................................................................................1 Electromagnetic Compatibility (EMC) ....................................15 Model Selection ........................................................................2 Immunity to Environmental Conditions ..................................17 Part Number Description and Product Marking ........................3 Mechanical Data ....................................................................18 Functional Description ..............................................................4 Safety and Installation Instructions ........................................19 Electrical Input Data..................................................................5 Description of Options ............................................................23 Electrical Output Data ..............................................................8 Accessories ............................................................................32 Auxiliary Functions..................................................................12 EC-Declaration of Conformity ................................................33 APR 26, 2006 revised to SEP 25, 2006 Page 1 of 33 www.power-one.comS Series Data Sheet 100 Watt AC-DC and DC-DC Converters Model Selection Non-standard input/output configurations or special custom adaptions are available on request. Table 1a: Model types AS 1 Output 1 Output 2 Input Voltage Efficiency Options V I V I V - V o nom o nom o nom o nom i min i max VDC A VDC A 8 to 35 VDC % 5.1 16 - - AS1001-7R 76 -9 12 8 - - AS1301-7R 81 D 2 15 6.5 - - AS1501-7R 83 V 24 4.2 - - AS1601-7R 84 P 3 12 4 12 4 AS2320-7R 79 T 3 15 3.2 15 3.2 AS2540-7R 80 B1, B2 3 24 2 24 2 AS2660-7R 80 Table 1b: Model types BS, CS, and FS 1 1 1 Output 1 Output 2 Input Voltage Eff. Input Voltage Eff. Input Voltage Eff. Options V I V I V - V V - V V - V o nom o nom o nom o nom i min i max i min i max i min i max VDC A VDC A 14 to 70 VDC % 28 to 140 VDC % 20 to 100 VDC % 5.1 16 - - BS1001-7R 77 CS1001-7R 77 FS1001-7R 77 -9 4 4 12 8 - - BS1301-7R 83 CS1301-7R 83 FS1301-7R 83 E , -9E 2 15 6.5 - - BS1501-7R 85 CS1501-7R 84 FS1501-7R 84 V 24 4.2 - - BS1601-7R 86 CS1601-7R 85 FS1601-7R 86 P 3 12 4 12 4 BS2320-7R 80 CS2320-7R 80 FS2320-7R 80 T 3 15 3.2 15 3.2 BS2540-7R 82 CS2540-7R 82 FS2540-7R 82 B1, B2 3 24 2 24 2 BS2660-7R 82 CS2660-7R 82 FS2660-7R 82 Table 1c: Model types DS, ES, and LS 1 1 1 Output 1 Output 2 Input Voltage Eff. Input Voltage Eff. Input Voltage Eff. Options V I V I V - V V - V V - V o nom o nom o nom o nom i min i max i min i max i min i max VDC A VDC A 44 to 220 VDC % 67 to 385 VDC % 88 to 372 VDC % 85 to 264 VAC 4 4 5.1 16 - - DS1001-7R 79 ---- -- LS1001-7R 78 E , -9E 12 8 - - DS1301-7R 84 ES1301-7R 83 LS1301-7R 83 D 2 15 6.5 - - DS1501-7R 86 ES1501-7R 84 LS1501-7R 84 V 24 4.2 - - DS1601-7R 86 ES1601-7R 86 LS1601-7R 85 P 3 12 4 12 4 DS2320-7R 81 ES2320-7R 81 LS2320-7R 80 T 3 15 3.2 15 3.2 DS2540-7R 82 ES2540-7R 83 LS2540-7R 81 B1, B2 3 24 2 24 2 DS2660-7R 83 ES2660-7R 83 LS2660-7R 81 1 Min. efficiency at V , I , and T = 25 C (DC input for LS models). Typical values are approx. 2% better. i nom o nom A 2 Option V for S1001 models only. 3 Second output semi-regulated. 4 Option E only for CS, DS, ES, FS, and LS models mandatory for all -9 models. APR 26, 2006 revised to SEP 25, 2006 Page 2 of 33 www.power-one.com