Cassette Style 100 Watt AC-DC Converters S Series PFC 100 Watt AC-DC Converters with PFC S Series Input voltage range from 85...264 V AC 1 or 2 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage Universal input voltage range Power factor >0.95, harmonics <IEC/EN 61000-3-2 Input over- and undervoltage lock-out Efcient input lter and built-in surge and transient suppression circuitry Fully isolated outputs Outputs overload, open- and short-circuit proof No derating over entire operating temperature range Safety according to IEC/EN 60950 LGA 111 4.4 3 U 60 168 2.4 6.6 12 TE Summary The S 4000/S 5000 series of AC-DC converters represents a exible range of power supplies for use in advanced elec- tronic systems. Features include full power factor correc- agencies LGA (Germany) and UL (USA). The UL Mark for tion, high efciency, high reliability, low output voltage noise Canada has been ofcially recognized by regulatory au- and excellent dynamic response to load/line changes. thorities in provinces across Canada. The converter inputs are protected against surges and tran- The case design allows operation at nominal load up to sients occurring at the source lines. An input over- and 71C in a free air ambient temperature. If forced cooling is undervoltage lock-out circuitry disables the outputs if the provided, the ambient temperature may exceed 71C but input voltage is outside the specied range. Inrush current the case temperature must remain below 95C under all limitation is included preventing circuit breakers and fuses conditions. from being damaged at switch-on. A temperature sensor generates an inhibit signal which All outputs are overload, open- and short-circuit proof and disables the outputs if the case temperature T exceeds C are protected against overvoltages by means of a built-in the limit. The outputs are automatically re-enabled when suppressor diode. The outputs can be inhibited by a logic the temperature drops below the limit. signal applied to the connector pin 18 (i). If the inhibit func- Various options are available to adapt the converters to in- tion is not used pin 18 must be connected to pin 14 to en- dividual applications. able the outputs. The modules may either be plugged into 19 rack systems LED indicators display the status of the converter and allow according to DIN 41494, or be chassis mounted. visual monitoring of the system at any time. Full input to output, input to case, output to case and output Important: to output isolation is provided. The modules are designed These products are intended to replace the LS 1000 and and built according to the international safety standards LS 2000 in order to comply with IEC/EN 61000-3-2. IEC/EN 60950 and have been approved by the safety Table of Contents Page Page Summary .......................................................................... 1 Electromagnetic Compatibility (EMC) ............................ 15 Type Survey and Key Data .............................................. 2 Immunity to Environmental Conditions........................... 17 Type Key .......................................................................... 2 Mechanical Data ............................................................ 18 Functional Description...................................................... 3 Safety and Installation Instructions ................................ 19 Description of Options .................................................... 22 Electrical Input Data ......................................................... 4 Electrical Output Data ...................................................... 6 Accessories .................................................................... 27 Auxiliary Functions ......................................................... 11 Edition 01/01.2001 1/27Cassette Style 100 Watt AC-DC Converters S Series PFC Type Survey and Key Data Non standard input/output configuration or special custom adaptions are available on request. See also: Commercial Infor- mation: Inquiry Form for Customized Power Supply. Table 1: Type survey LS 1 Output 1 Output 2 Input Voltage Range Efficiency Options U I U I U ...U h o nom o nom o nom o nom i min i max min 2 2 6 V DC A V DC A 85...255 V AC % 5.1 16.0 LS 4001-7R 77 -9 12.0 8.0 LS 4301-7R 81 E 15.0 6.5 LS 4501-7R 83 D 5 24.0 4.2 LS 4601-7R 83 V P 3 24.0 4.0 LS 5320-7R 81 T 3 30.0 3.2 LS 5540-7R 81 B1 3 48.0 2.0 LS 5660-7R 81 B2 4 12.0 4.0 12.0 4.0 LS 5320-7R 81 4 15.0 3.2 15.0 3.2 LS 5540-7R 81 4 24.0 2.0 24.0 2.0 LS 5660-7R 81 1 3 Efciency at U and I . Series connection of output 1 and 2, see: R-Function for differ- i nom o nom 2 If the output voltages are increased above U via R-input o nom ent output configurations. 4 control, option P setting, remote sensing or option T, the output Second output semi-regulated. 5 currents must be reduced accordingly so that P is not ex- Option V for LS 4000 types with 5 V outputs. o nom 6 ceeded. For DC-input please ask your local Power-One partner. Type Key Type Key L S 5 5 40 -7 E R P D V T B1 Input voltage range U : 85...255 V AC .............................. L i Series ...............................................................................S Number of outputs (4 for single, 5 for double outputs) 4...5 Single output units: Nominal voltage output 1 (main output), U o1 nom 5.1 V .................................................... 0, 1, 2 12 V ............................................................. 3 15 V ......................................................... 4, 5 24 V ............................................................. 6 other voltages .......................................... 7, 8 Other specifications for single output modules ....... 01...99 Symmetrical double output units: Nominal voltage output 1/output 2, U o1/2 nom 1 12 V/12 V (24 V series conn.) .................. 20 1 15 V/15 V (30 V series conn.) .................. 40 1 24 V/24 V (48 V series conn.) .................. 60 other symmetrical voltages ................. 70...99 Operational ambient temperature range T : A 25...71C .................................................. -7 40...71C .................................................. -9 customer specific .................................. -0...-6 Auxiliary functions and options: Inrush current limitation ............................... E 2 Output voltage control input ........................ R 2 Potentiometer (output voltage adjustment) .. P 3 Save data signal (D0...DD, to be specified) D 3, 4 ACFAIL signal (V2, V3)................................ V Current sharing ............................................ T Cooling plate standard case ...................... B1 Cooling plate for longe case 220 mm ........ B2 1 External wiring of main and second output depending upon the desired output configuration (see: R-Function for different output con- figurations). 2 Feature R excludes option P and vice versa. 3 Option D excludes option V and vice versa. 4 Option V available for LS 4000 types with 5V output. Edition 01/01.2001 2/27