MAP110 AC-DC Series Data Sheet Features RoHS lead-solder-exemption compliant New 3.3 V and 5 V output models Universal input 85-264 VAC Industry-standard footprint: 7.00 x 4.30 x 1.97 (177.8 x 109.2 x 50.0 mm) Input transient & ESD compliance to EN61000-4-2/-3/-4 Greater than 134,000 hours MTBF Remote sense and overvoltage protection on single output units and main output of multiple output units Options include overtemperature protection, Power Fail signal, chassis, & cover Description Power-Ones MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. Single-Output Model Selection OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012 12V 11.25V to 12.75V 7.5A 10A 0.1% 0.5% 1% 11.97V to 12.02V MAP110-1024 24V/28V 22.8V to 29.2V 3.8/3.2A (Note 2) 5.0/4.3A (Note 2) 0.1% 0.5% 1% 23.95V to 24.05V NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) MAP110-1024 output currents are expressed as 24V/28V operation. Multiple-Output Model Selection 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM) OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) CURRENT REGULATION REGULATION %p-p (NOTE 2) ACCURACY +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.2% 1% 1% 11.97V to 12.03V MAP110-4000 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1% 1% -11.4V to -12.6V -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +24V Fixed 3A/4.5A PK 3A/4.5A PK 0.1% 1% 1% 23.94V to 24.06V MAP110-4001 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4002 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +15V Fixed 5A/7.3A PK 5A/7.3A PK 0.1% 1% 1% 14.96V to 15.04V MAP110-4003 -15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.3V to -15.7V -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +24V Fixed 3A/4.5A PK 3A/4.5A PK 0.1% 1% 1% 23.94V to 24.06V MAP110-4004 -15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.3V to -15.7V +15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 14.3V to 15.7V Model numbers highlighted in yellow or shaded are not recommended for new designs. MCD10142 Rev. 2.0, 23-Aug-11 Page 1 of 5 www.power -one.comMAP110 AC-DC Series Data Sheet Multiple-Output Model Selection (Cont.) 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM) OUTPUT ADJUSTMENT CONVECTION COOLED FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT (NOTE 1) CURRENT REGULATION REGULATION %p-p (NOTE 2) ACCURACY +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 2% 1% 11.97V to 12.03V MAP110-4010 -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V -12V Fixed 3A/4A PK 3A/4A PK 0.3% 8% 1% -11.5V to -12.5V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4011 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +24V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 23.2V to 24.8V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4015 -15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.4V to -15.6V +15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 14.4V to 15.6V +12V 11.55V to 12.45V 5A/9A PK 5A/9A PK 0.2% 0.5% 0.5% 11.96V to 12.03V +24V Fixed 4A/4.5A PK 4A/4.5A PK 0.2% 1% 1% 23.94V to 24.06V MAP110-4200 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1% 1% -11.4V to -12.6V +5V Fixed 2A/2.5A PK 2A/2.5A PK 0.2% 1.5% 1% 4.75V to 5.25V +3.3V 3.2V to 3.4V 12A/20A PK 15A/20A PK 0.3% 0.7% 1% 3.29V to 3.31V +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V MAP110-4300 -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V (Note 3) +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V +3.3V 3.2V to 3.4V 12A/15A PK 15A/20A PK 0.3% 0.7% 1% 3.29V to 3.31V +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V MAP110-4305 -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -4.75V to -5.25V (Note 3) +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V NOTES: 1) Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak. Model numbers highlighted in yellow or shaded are not recommended for new designs. Maximum Output Rtating: MODEL/OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT MULTIPLE OUTPUT SINGLE OUTPUT OPTION BOARD ONLY BOARD ONLY L-BRACKET L-BRACKET C-COVER C-COVER CONVECTION CONTINUOUS/PEAK 80W/110W 90W/120W 80W/110W 90W/120W 60W/110W 65W/120W FORCED AIR 200 LFM 110W 120W 110W 120W 110W 120W Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC input voltage (110 VAC) 50% load: 40 mS Full rated load: 20 Input Current 85 VAC (110W load). 3.5 ARMS 110VAC (110W load). 2.8 Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 C. 41 APK Operating Frequency Switching frequency of main transformer, (fixed frequency). 20 25 kHz MCD10142 Rev. 2.0, 23-Aug-11 Page 2 of 5 www.power-one.com