MAP130 AC-DC Series Data Sheet
Features
RoHS lead-solder-exemption compliant
Automatic 115/230 input voltage selection
All outputs fully regulated
Remote sense, overvoltage protection, and
overtemperature protection
Power Fail signal included
Greater than 100,000 Hour MTBF
U-Channel chassis: 8.50" x 4.50" x 2.00"
(215.9mm x 114.3mm x 50.8mm)
Optional cover
Metric and SAE mounting inserts
Description
Power-Ones MAP130 Series of single and multiple output power supplies provide fully-regulated outputs with high
peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include autos-
elect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE
mounting inserts.
This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to
50 C. All products are approved to the latest international regulatory standards and display the CE Mark.
Single Output Model Selection
OUTPUT ADJUSTMENT CONTINUOUS PEAK LINE LOAD TYPICAL RIPPLE & INITIAL SETTING
MODEL
VOLTAGE RANGE CURRENT CURRENT (NOTE 3) REGULATION REGULATION NOISE %p-p (NOTE 1) ACCURACY
MAP130-1005 5V 4.75V to 5.50V 26A 30A 0.2% 1% 1% 5.1V to 5.2V
MAP130-1012 12V/15V 11.4V to 15.75V 12A/10A (Note 2) 13.8A/11A 0.2% 1% 1% 12.0V to 12.2V
MAP130-1024 24V/28V 22.5V to 30.0V 6.2A/5.4A (Note 2) 6.8A/5.9A 0.2% 1% 1% 23.9V to 24.1V
NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
Multiple Output Model Selection 130W Continuous Output Power
OUTPUT ADJUSTMENT OUTPUT PEAK CURRENT LINE LOAD TYPICAL RIPPLE & INITIAL SETTING
MODEL
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION NOISE %p-p (NOTE 2) ACCURACY
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V
+12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.75V to 12.0V
MAP130-4000
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V
+24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V
MAP130-4001
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.2V
+12V 11.5V to 12.5V 5A 10A 0.5% 2% 1% 11.9V to 12.1V
MAP130-4002
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V
Model numbers highlighted in yellow or shaded are not recommended for new designs.
MCD10115 Rev. 1.3, 05-Feb-10 Page 1 of 4 www.power-one.comMAP130 AC-DC Series Data Sheet
Multiple Output Model Selection (Cont.) 130W Continuous Output Power
OUTPUT ADJUSTMENT OUTPUT PEAK CURRENT LINE LOAD TYPICAL RIPPLE & INITIAL SETTING
MODEL
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION NOISE %p-p (NOTE 2) ACCURACY
+5V 4.75V to 5.50V 20A 30A 1% 1% 1% 5.1V to 5.2V
+15V 14.0V to 16.0V 4A 8A 1% 2% 1% 15.0V to 15.1V
MAP130-4003
-5V Fixed 1A 1A 2% 2% 1% -4.8V to -5.2V
-15V Fixed 1A 1A 2% 2% 1% -14.7V to -15.3V
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.15V to 5.2V
+24V 23.0V to 25.0V 3.5A 5A 0.5% 2% 1% 23.9V to 24.1V
MAP130-4004
-15V Fixed 1A 1A 0.5% 2% 1% -14.5V to -15.5V
+15V Fixed 1A 1A 0.5% 2% 1% 14.5V to 15.5V
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.25V
+12V 11.5V to 12.8V 5A 10A 0.5% 2% 1% 11.75V to 12.0V
MAP130-4010
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.2V
-12V Fixed 3A 3A 0.5% 2% 1% -11.6V to -12.4V
+5V 4.75V to 5.50V 20A 30A 0.2% 1% 1% 5.1V to 5.25V
+12V 11.5V to 12.8V 5A 10A 0.5% 2% 1% 11.75V to 12.0V
MAP130-4020
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
-5V Fixed 3A 3A 0.5% 2% 1% -4.8V to -5.2V
NOTES: 1) Peak loads up to 165 Watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.).
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage- AC Auto-ranging. Low Range 90 115 132
VAC
High Range 175 230 264
Input Frequency AC Input. 47 63 Hz
Brown out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC
Hold-up Time Nominal AC input voltage (115 VAC). 130W load: 40 mS
Input Current 90 VAC, 130W load. 3.3 ARMS
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 C. 38 APK
Operating Frequency Switching frequency of main transformer (variable). Range: 16 120 kHz
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full Load, 115VAC. Varies with distribution of loads among outputs. 71 80 %
Minimum Loads MAP130-1012. 1.25
MAP130-1024. 0.63 Amps
MAP130-1005 and all multiple output models, main channel only. 3.00
Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart
Output Power Continuous output power, all multiple output models. 130
Watts
Peak output power (60s maximum, 10% duty cycle), all multiple output models. 165
Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on / turn-off 1 %
Regulation Varies by output, Total regulation includes: line changes from 90-132 VAC
See Model Selection Chart
or 175-264, changes in load starting at 20% load and changing to 100% load.
Transient Response Recovery time to within 1% of initial set point due to a 50-100% load change,
500 S
4% max. deviation. (Main output only on multi-output units)
Turn-on Delay Time required for initial output voltage stabilization. 2 Sec
Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS
MCD10115 Rev. 1.3, 05-Feb-10 Page 2 of 4 www.power-one.com