MAP140 AC-DC Series Data Sheet
Features
RoHS lead-solder-exemption compliant
Universal input 85-264 VAC
Input transient & ESD compliance to EN61000-4-2/-3/-4
CE marked to Low Voltage Directive
Industry-standard footprint: 7.00" x 4.30" x 1.80"
(177.8mm x 109.2mm x 45.7mm)
Remote sense and overvoltage protection
Power Fail signal standard on MAP140-3000P, optional
on MAP140-1012 and MAP140-1024
Optional overtemperature protection, L-bracket, and cover
Description
Power-Ones MAP140 Series provides a full range of options and up to 30 watts more power than comparable
products in this industry-standard footprint. With a universal input from 85 to 264 VAC and power densities up to 2.6
watts/inch3, the MAP140 meets the most rigorous requirements of commercial, industrial, and datacom systems.
Rated for use in convection and forced-air cooled (200 LFM) applications, the MAP140 delivers dependable power
with a Mean Time Between Failures (MTBF) in excess of 180,000 hours. In addition to UL, CSA, and TV regulatory
compliance, the MAP140 displays the CE Mark.
Single Output Model Selection
OUTPUT ADJUSTMENT CONVECTION FORCED AIR LINE LOAD RIPPLE & NOISE INITIAL SETTING
MODEL
VOLTAGE RANGE COOLED CURRENT CURRENT (NOTE 3) REGULATION REGULATION %p-p (NOTE 1) ACCURACY
MAP140-1012 12V/15V 11.0V to 16.0V 9.2/7.3A (Note 2) 12.5A/10A (Note 2) 0.1% 0.5% 1% 11.97V to 12.03V
MAP140-1024 24V/28V 22.8V to 29.2V 4.6/4A (Note 2) 6.3A/5.4A (Note 2) 0.1% 0.5% 1% 23.95V to 24.05V
MAP140-1048 48V 45.6V to 54.0V 2.3A 3.1A 0.1% 0.5% 1% 47.9V to 48.1V
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024 output currents are expressed as 24V/28V operation.
3) With 200 LFM forced air cooling.
Multiple Output Model Selection 80W Convection Cooled, 140W Forced-Air Cooled (200 LFM)
OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
MODEL
VOLTAGE RANGE CURRENT (NOTE 1) CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
+5V 4.75 - 5.25V 16A/25A 20A/25A PK 0.2% 1% 1% 5.09V to 5.11V
MAP140-3000P +12V Fixed 4A/9A PK 4A/9A PK 0.1% 2% 1% 11.97V to 12.03V
-12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 2% 1% -11.4V to -12.6V
NOTES: 1) Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
MCD10167 Rev. 1.0, 04-Jun-10 Page 1 of 4 www.power-one.comMAP140 AC-DC Series Data Sheet
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 85 264 VAC
Input Frequency AC input. 47 63 Hz
Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC
Hold-up Time Nominal AC input voltage (110 VAC) 110 watt load: 20
mS
140 watt load: 16
Input Current 85 VAC (140W load). 2.5
ARMS
110 VAC (140W load). 2.0
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25C. 41 APK
Operating Frequency Switching frequency of main transformer. 22 kHz
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full load, 110 VAC. Varies with distribution of loads among outputs. 65 70 80 %
Minimum Loads Single output models. 0
Amps
MAP140-3000P, total output current of V1 + V2 (Note 1). 2
Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart.
Output Power Single output models. See Model Selection Chart.
MAP140-3000P with convection cooling. 80
Watts
MAP140-3000P with 200 LFM forced air cooling. 140
Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on/turn-off. 0 V
Regulation Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264,
See Model Selection Chart.
changes in load starting at 20% load and changing to 100% load.
Transient Response Recovery time, to within 1% of initial set point due to a 50-100%
500 S
load change, 4% max. deviation.
Turn-on Delay Time required for initial output voltage stabilization. MAP140-3000P 1
Sec
Single output models 2
Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 mS
NOTES: 1) Minimum load is required only to meet the regulation limits of V3.
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection Provided on single output models MAP140-3000P, V1 6.1 7.2
and V1 of MAP140-3000P. MAP140-1012 17.3 20.2
V
MAP140-1024 32.2 37.8
MAP140-1048 55.2 64.8
Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Remote Sense Voltage drop compensated for at the load. 250 mV
Input Power Fail TTL compatible logic signal. Time before regulation dropout due
Warning to loss of input power at 140 watts, 110 VAC. Standard on MAP140-3000P 2.3 mS
and optional on MAP140-1012.
Overtemperature Protection Optional signal provides system shutdown due to excessive internal temperature. See options.
MCD10167 Rev. 1.0, 04-Jun-10 Page 2 of 4 www.power-one.com