MAP30/40/42 AC-DC Series Data Sheet Features RoHS lead-solder-exemption compliant Universal input 85-264 VAC CE marked to Low Voltage Directive Input transient & ESD compliance to EN61000-4-2/-3/-4 Meets EN55022 conducted and radiated limits Greater than 311,000 Hours MTBF Remote sense (MAP30, MAP42) Description Power-Ones MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Fixed frequency operation simplifies system level operation. The MAP30/40/42 Series is configured to the international standard 3.00 x 5.00 footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. Single-Output Model Selection OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT CURRENT (NOTE 2) REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP30-1005 5V 4.7V to 5.8V 6A 8A 0.2% 1% 1% 4.9V to 5.1V MAP42-1005 5V 4.7V to 5.8V 8A 11A 0.2% 1% 1% 4.9V to 5.1V MAP42-1012 12V/15V 11.0V to 18.0V 3.4/2.7A (Note 3) 4.6/3.7A (Note 3) 0.2% 1% 1% 11.9V to 12.1V MAP42-1024 24V/28V 23.0V to 29.0V 1.7/1.4A (Note 3) 2.3/1.9A (Note 3) 0.2% 1% 1% 23.8V to 24.2V NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling. 3) MAP42-1012 output currents are expressed as 12V/15V operation. MAP42-1024 output currents are expressed as 24V/28V operation. Multiple-Output Model Selection 40W CONTINUOUS OUTPUT POWER OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY +5V 4.75V to 5.50V 3A 5A 0.2% 2% 1% 4.9V to 5.1V MAP40-3000 +12V Fixed 2A 3.5A 1% 3.5% (Note 3) 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% 2% (Note 4) 1% -11.4V to -12.6V +5V 4.75V to 5.25V 3A 5A 0.2% 2% 1% 4.9V to 5.1V MAP40-3100 +12V Fixed 2A 3.5A 1% 3.5% (Note 3) 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.4V to -12.6V +5V 4.75V to 5.25V 3A 5A 0.2% 2% 1% 4.9V to 5.1V MAP40-3101 +24V Fixed 1A 1.5A 1% 3.5% (Note 3) 1% 23.0V to 25.0V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.5V to -12.5V +5V 4.7V to 5.8V 3A 5A 0.2% 2% 1% 4.9V to 5.1V MAP40-3105 +12 Fixed 2A 3.5A 1% 3.5% (Note 3) 1% 11.5V to 12.5V -5V Fixed 0.5A 1.0A 1% 2% 1% -4.75V to -5.25V +5V 4.7V to 5.8V 5A 6A 0.2% 2% 1% 4.9V to 5.1V MAP40-3500 +12V Fixed 1A 3.5A 1% 3.5% (Note 3) 1% 11.5V to 12.5V -12V Fixed 0.3A 0.5A 1% 2% 1% -11.4V to -12.6V +5V 4.7V to 5.8V 3A 5A 0.2% 2% 1% 4.9V to 5.1V MAP40-3003 +15V Fixed 1.5A 3A 1% 3.5% (Note 3) 1% 14.7V to 15.3V -15V Fixed 0.2A 0.5A 1% 2% (Note 4) 1% -14.3V to -15.7V NOTES : 1) Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.). 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Quasi regulated output. See Regulation Curves for more information. 4) Requires a minimum load of 0.5A on V1 or 0.3A on V2. Model numbers highlighted in yellow or shaded are not recommended for new designs. REV. JUN 19, 2006 revised to APR 13, 2007 Page 1 of 5 www.power-one.comMAP30/40/42 AC-DC Series Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. MAP42 85 264 VAC MAP30, MAP40 90 264 Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 15 ms Input Current 90 VAC (40W load). 1.2 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25 C. 38 APK Operating Frequency Switching frequency of power supply (fixed frequency). 23 25 30 kHz Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full load, 120VAC. 70 % Minimum Loads Single output models MAP30, MAP42. 0.0 Amps All multiple output models, see regulation graphs. Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart. Output Power Multiple output models with convection cooling. 40 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1. 1 % Regulation Varies by output, total regulation includes: Line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing See regulation graphs. to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% 500 s load change, 4% max. deviation. (Main output only of multiple output units). Turn-on Delay Time required for initial output voltage stabilization. 1 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS MAP30-1005, MAP42-1005 5.8 6.8 Overvoltage MAP42-1012 20.0 22.0 V Protection MAP42-1024 32.0 37.0 Main output only of multiple output units. 5.8 6.8 Overload Fully protected against output overload and short circuit. Automatic 130 % Protection recovery upon removal of overload condition. Remote Sense Total cable drop, single output models only. 250 mV Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL60950. CSA 22.2 No. 60950. Approved. EN60950 (TUV). Dielectric Withstand Input to output. 2600 VDC Voltage Electromagnetic FCC CFR title 47 part 15 sub-part B - conducted. B Interference EN55022 / CISPR 22 conducted (Note 1). B Class EN55022 / CISPR 22 radiated (Note 2). B Input Transient EN61000-4-5 Level 3 Line to Line 1 kV Protection Line to Ground 2 Insulation Resistance Input to output. 7 M Leakage Current Per EN60950, 264VAC MAP42, MAP40-3100, 3001, 3105, 3500 500 A MAP30-1005, MAP40-3000, MAP40-3003 750 NOTES: 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A. 2) MAP40-3000, MAP40-3003, MAP3500 meet Class A. REV. JUN 19, 2006 revised to APR 13, 2007 Page 2 of 5 www.power-one.com