MAP55 AC-DC Series Data Sheet Features RoHS lead-solder-exempt compliant Wide Range Input for 110/220 VAC Applications Meets EN55022, Conducted Class B Limits Compact Footprint: 6.00 x 3.27 x 1.60 (152.4mm x 83.1mm x 40.6mm) Greater than 225,000 Hours MTBF Metric and SAE Mounting Inserts Description Power-One s MAP55 Series of power supplies provides reliable, tightly-regulated DC power for commercial and industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. The MAP55 utilizes a thermally efficient U-channel chassis design, which allows full power operation in convection- cooled applications. Other mechanical design innovations include metric and SAE mounting inserts on each mounting surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular single row Molex connector mating. Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. Single-Output Model Selection OUTPUT ADJUSTMENT MAXIMUM OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT CURRENT (NOTE 3) REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP40-1005 5V 4.7V to 5.50V 8A 11A 0.2% 1.5% 1% 5.0V to 5.2V MAP55-1012 12V/15V 11.4V to 15.75V 5.0/4.0A (Note 2) 5.8/4.7A (Note 2) 0.2% 1% 1% 12.0V to 12.2V MAP55-1024 24V/28V 23.5V to 28.5V 2.5/2.2A (Note 2) 2.9/2.5A (Note 2) 0.2% 1% 1% 23.8V to 24.2V NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple-Output Model Selection 55W Continuous Output Power OUTPUT ADJUSTMENT OUTPUT PEAK OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING MODEL VOLTAGE RANGE CURRENT CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY +5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V MAP55-4000 +12V Fixed 3A 5A 0.2% 2% 1% 11.6V to 12.4V -5V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -4.8V to -5.2V -12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -11.6V to -12.4V +5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V MAP55-4001 +24V Fixed 1.5A 2.5A 0.2% 2% 1% 23.0V to 24.9V -12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% 11.6V to 12.4V +5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V +12V Fixed 3A 5A 0.2% 2% 1% 11.6V to 12.4V MAP55-4002 -12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -11.6V to -12.4V +12V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% 11.6V to 12.4V +5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V +15V Fixed 2.5A 3.5A 0.2% 2% 1% 14.6V to 15.4V MAP55-4003 -5V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -4.8V to -5.2V -15V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -14.4V to -15.6V +5V 4.7V to 5.6V 6A 8A 0.2% 2% 1% 5.0V to 5.2V +24V Fixed 1.5A 2.5A 0.2% 2% 1% 23.0V to 24.9V MAP55-4004 -15V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% -14.5V to -15.5V +15V Fixed 0.5A 1A (Note 3) 0.5% 2% 1% 14.5V to 15.5V NOTES: 1) Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded. JUL 14, 2006 revised to AUG 10, 2006 Page 1 of 3 www.power-one.comMAP55 AC-DC Series Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 90 132 VAC 175 264 Input Frequency AC input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC Hold-up Time Nominal AC Input Voltage (115VAC), full rated load. 20 ms Input Current 90 VAC (55W load). 1.6 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264VAC (one cycle). 25 C. 38 APK Operating Frequency Switching frequency of power supply (varies with load). 22 180 kHz Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full load, 115VAC. Varies with distribution of loads among outputs. 73 % Minimum Loads MAP55-1012 0.21 MAP55-1024 0.11 Amps MAP40-1005 and all multiple output models, main channel only. 0.50 Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Chart. Output Power Continuous output power, all multiple output models. 55 Watts Peak output power (60s maximum, 10% duty cycle), all multiple output models. 65 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on, V1, V2. 1 % Regulation Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264 VAC, See Model Selection Chart. changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 50-100% 500 s load change, 4% max. deviation. (Main output of multiple output units). Turn-on Delay Time required for initial output voltage stabilization. 1 4 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90% (Note 1). 7 ms NOTES: 1) Nominal rise time for MAP55-1024 is 36 msec. Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection MAP40-1005 5.5 6.8 MAP55-1012 17.5 19.7 V MAP55-1024 32.0 36.0 Main output only of multiple output units. 5.6 6.8 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 No. 234/950. Approved. EN60950 (TUV). Dielectric Withstand Input to output. 2600 VDC Voltage Electromagnetic FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated. B Interference, EN55022 / CISPR 22 conducted. B Class Conducted EN55022 / CISPR 22 radiated. A Insulation Resistance Input to output. 7 M Leakage Current Per EN60950, 264VAC. 500 A NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. JUL 14, 2006 revised to AUG 10, 2006 Page 2 of 3 www.power-one.com