Bel Power Solutions MAP80 Series of power supplies provides
reliable, tightly-regulated DC power for commercial and industrial
systems which require high peak current capabilities. Wide-range AC
input and full international safety, EMI, and ESD compliance ensure
worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally
efficient U-channel chassis to provide full power operation in
convection-cooled applications. Design innovations include metric
and SAE mounting inserts on each mounting surface to provide
integration flexibility. Dual-mode connectors provide traditional
terminal block connections or popular single-row Molex connector
mating.
Single-output models feature wide-range output adjustability to meet
a wide variety of standard and user-specific output voltage
requirements.
RoHS Compliant
Wide Range Input for 110/220 VAC Applications
CE marked to Low Voltage Directive
Input Transient and ESD Compliance to EN61000-4-2/-3/-4
Meets EN55022, Class B Limits
TTL Compatible Power Fail Signal
Greater than 175,000 Hours MTBF
Metric and SAE Mounting Inserts
2
MAP80 Series
MAX PEAK RIPPLE
OUTPUT ADJUSTMENT LINE LOAD INITIAL SETTING
7
MODEL OUTPUT OUTPUT &
VOLTAGE RANGE REGULATION REGULATION ACCURACY
1 2
CURRENT CURRENT NOISE
6 3
MAP80-1012G 12V/15V 11.5V to 15.5V 7.5/6.0A 9.2/7.3A 0.2% 1% 1% 11.76V to 12.15V
6
MAP80-1024G 24V/28V 23.0V to 29.0V 3.8/3.2A 4.6/3.9A 0.1% 0.5% 0.5% 23.8V to 24.2V
PEAK RIPPLE
OUTPUT ADJUSTMENT OUTPUT LINE LOAD INITIAL SETTING
7
MODEL OUTPUT &
VOLTAGE RANGE CURRENT REGULATION REGULATION ACCURACY
4 2
CURRENT NOISE
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
+12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 11.9V to 12.1V
5
MAP80-4000G
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V
-12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
+24V 23.04V to 24.96V 2A 3.5A 0.2% 1% 1% 24.0V to 24.1V
5
MAP80-4001G
-12V Fixed 1A 1A 0.5% 2% 1% -11.5V to -12.5V
+12V Fixed 1A 1A 0.5% 2% 1% 11.5V to 12.5V
+5V 4.7V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
+12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V
5
MAP80-4002G
-12V Fixed 1A 1A 0.5% 2% 1% -11.6V to -12.4V
+12V Fixed 1A 1A 0.5% 2% 1% 11.6V to 12.4V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
+15V 14.4V to 15.6V 3.5A 6A 0.2% 1% 1% 14.6V to 15.1V
5
MAP80-4003G
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V
-15V Fixed 1A 1A 0.5% 2% 1% -14.4V to -15.5V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
+24V 23.04V to 24.96V 2A 3.5A 0.2% 1% 1% 24.0V to 24.1V
5
MAP80-4004G
-15V Fixed 1A 1A 0.5% 2% 1% -14.4V to -15.5V
+15V Fixed 1A 1A 0.5% 2% 1% 14.4V to 15.5V
+5V 4.8V to 5.5V 14A 16A 0.2% 1% 1% 5.1V to 5.2V
+12V 11.52V to 12.48V 4A 7A 0.2% 1% 1% 12.0V to 12.1V
5
MAP80-4010G
-5V Fixed 1A 1A 0.5% 2% 1% -4.8V to -5.4V
-12V Fixed 3A 3A 0.5% 2% 1% -11.5V to -12.5V
1
Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
2
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3
MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
4
Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts.
5
Output rated 65 W max for 50C ambient, convection cooled.
6
Output rated 75 W max for 50C ambient, convection cooled.
7
Non-G models use lead solder exemption and are not recommended for new designs.