The MPB150 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. MPB150s deliver a regulated main output plus a second 12V output for fans or other system functions. The MPB150 is rated for convection as well as forced-air cooling. Full output power is available with as few as 15 Cubic Feet per Minute (CFM) forced-air cooling. The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark. RoHS Compliant for All Six Substances High Power Density Industry-Standard 3 x 5 Footprint Power Factor Correction (PFC) Meets EN61000-3-2 Main Output Remote Sense Power Good Signals CE Marked to Low Voltage Directive Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5 North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 tech.support psbel.com 2015 Bel Power Solutions, Inc. BCD.00605 AA END OF LIFEMPB150 Dual-Output AC-DC Series 1 OUTPUT MAXIMUM OUTPUT TOTAL REGULATION RIPPLE & NOISE REGULATION MODEL VOLTAGE V CURRENT (AMPS), 130 LFM % % pk-pk RANGE +12V 12.5A 3% 1% 11.64V to 12.36V 2, 3, 4 MPB150-2012G 12V 0.5A 5% 1% 11.40V to 12.60V +24V 6.0A 3% 1% 23.28V to 24.72V 2, 3, 4 MPB150-2024G 12V 0.5A 5% 1% 11.40V to 12.60V +48V 3.1A 3% 1% 46.56V to 49.44V 2, 3, 4 MPB150-2048G 12V 0.5A 5% 1% 11.40V to 12.60V NOTES: 1 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2 Maximum forced-air output power is 150 watts with 15 CFM airflow. 3 Maximum convection output power is 70 watts. 4 V2 is isolated from V1 and can be used as a negative or positive output. PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage- AC Continuous input range 90 264 VAC Input Frequency AC Input 47 63 Hz Lowest AC input voltage that regulation is maintained with full rated Brownout Protection 90 VAC loads Hold-up Time Over full AC input voltage range at full rated load 17 ms Input Current 90 VAC at full rated load 2.2 ARMS Non-user serviceable internally located AC input line fuse, 250 VAC, Input Protection 3.15A 110VAC: 23 Inrush Surge Current Internally limited by thermistor, one cycle, 25C A PK 220VAC: 46 Power Factor Circuitry Active PFC meets requirements of EN61000-3-2 Operating Frequency Switching frequency of main transformer 45 kHz PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full Load, 230VAC. Varies with distribution of loads among outputs. 75 80 85 % V1 load for full regulation on V2. All models operate at no load Minimum Loads 5 Watts without any damage and meet all specs on V1 above 0 amps. Full load, 20 MHz bandwidth Ripple and Noise See Model Selection Chart At 15 CFM forced-air cooling. See Application Note for details. Output Power (Note 1) 150 Watts Convection: Consult Factory. Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on 10 % Varies by output. Total regulation includes: line changes from 85-132 Regulation VAC or 170-264 VAC, changes in load starting at 20% load and See Model Selection Chart changing to 100% load. Maximum deviation due to a 25% load change with unit at 75% load. Transient Response 3 % Turn-on Delay Time required for initial output voltage stabilization 0.2 1.5 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90% 0.2 20 ms 866.513.2839 tech.support psbel.com 2015 Bel Power Solutions, Inc. BCD.00605 AA END OF LIFE