SPSPFE3-0XG power-shelf solutions provide rectification, system management, and power distribution, while maintaining high reliability and offering flexibility for future expansion. The power shelf can be configured with up to six hot-swap capable PFE3000-12-069RA AC/DC-DC power supplies that convert 3-phase AC mains power into a main output of 12 VDC for powering intermediate bus architectures (IBA) in high performance and reliability servers, routers, and network switches. The shelf is compatible with the Open Compute Rack Design. The shelf has an optional slot for Network Attached Controller for providing control functions and monitoring through a 10/100 MB base Ethernet port and can be connected directly to the data center management network. Two 3-Phase inputs, one AC inlet powers 3 power modules. Modules are hot-swap capable. 2 Modules support I C communication interface for control, programming and monitoring with PMBus protocol. Modules implement the following protections: Overtemperature, output overvoltage and output overcurrent. RoHS Compliant. Available for OCP V1 and V2 bus-bar style connection. High Performance Servers Routers Switches Disclaimer: PMBus is a registered trademark of SMIF, Inc. 2 SPSPFE3-0XG MODEL INPUT AND OUTPUT CONFIGURATION 3-phase, 200-277 / 346-480 VAC Line to Line input with Neutral line SPSPFE3-05G 3 sets of output blades for +12 VDC output (each set of blades has max.585 A) 3-phase, 200-277 / 346-480 VAC Line to Line input with Neutral line SPSPFE3-05CG 3 sets of output blades for +12 VDC output (each set of blades has max.585 A) Network Attached Controller included 3-phase, 200-277 / 346-480 VAC Line to Line input with Neutral line SPSPFE3-06G 1 set of output blade for +12 VDC output 3-phase, 200-277 / 346-480 VAC Line to Line input with Neutral line SPSPFE3-06CG 1 set of output blade for +12 VDC output Network Attached Controller included PARAMETER DESCRIPTION / CONDITION 1 Input 3-phase, 200-277 / 346-480 VAC Line to Line input with Neutral AC Inlet Configuration 3 power modules are powered from one AC inlet 3pcs. low power AC outlet providing 230 / 277 VAC output with max. 6A 10A, Auxiliary AC Outlet Protected by T 10A F 15 A / 500 VAC Fuse (serviceable) When T : +45 C to +55 C, Output load current must be derated to 75%. A Redundant Configuration 3+3 or 5+1 configuration 2 Rated Power 1 8700 W (3+3 configuration) 2 Rated Power 2 14400 W (5+1 configuration) SPSPFE-05G: 3 sets of output blades for +12 VDC output (each set of blades has max.585 A) Output Connection SPSPFE-06G: 1 set of output blade for +12 VDC output Standby Output 60 W (Standby output 12 V / 5 A) 2 Communication I C PMBus NAC1006-01 Network Attached Controller: Ethernet SNMPv3 / HTTP The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies Bel Power Solutions Inc. from all claims arising from the handling or use of the goods. Persons handling the product(s) must have electronics training and observe good engineering practice standards. CAUTION: Multiple power source. Disconnect all power cords before servicing. DOCUMENT NUMBER DESCRIPTION BCD.00297 PFE3000-12-069RA Datasheet BCA.00070 PFE3000-12-069RA PMBus Communication Manual BCM.00177 Installation Instruction PFE3000-12-069RA BCD.00926 NAC1006-01 Datasheet BCA.00178 SPSPFE3-0XG Communication Manual BCM.00444 Installation Instruction SPSPFE3-0XG PCA9547PW PCA9547PW Datasheet from NXP 1 Power modules are connected Line to Neutral. 2 Rated Power is reduced as per current share accuracy characteristic. See PFE3000-12-069RA Datasheet. tech.support psbel.com