The MBC150 Series of open-frame medical power supplies, with its wide universal input range 90-264 VAC, is available at 150 W of output power with forced-air cooling and a variety of single output voltages. The MBC series is designed and approved to the latest Medical standards (EN/IEC 60601-1), providing 2 x MOPP (Means of Patient Protection) isolation for Class I & Class II applications. These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications. 4 x 2 x 1.3 Inch Form Factor 150 W with Forced-Air Cooling Approved to EN/IEC 60601-1 12 V 0.5 A fan voltage auxiliary output High Efficiency > 86% Low conducted and radiated noise Light weight IEC Protection Class Options: Class I: Earthing Tab J4 (no suffix) Class II: No Earthing Tab (-2 suffix) Medical Safety Agency Approvals RoHS Compliant Diagnostic Dialysis Drug Pump Home Health Care Monitoring Portable Equipment 2 MBC150 Series MAX LOAD MAX LOAD RIPPLE & 1 MODEL CONNECTOR OUTPUT VOLTAGE MINIMUM LOAD 2 2,3, 4 5 CONVECTION 300 LFM NOISE 0.0 A MBC150-1005G JST 5 VDC 16.0 A 16.0 A 1% 0.0 A MBC150-1T05G Screw Terminal 5 VDC 16.0 A 20.0 A 1% 0.0 A MBC150-1012G JST 12 VDC 8.33 A 12.5 A 1% 0.0 A MBC150-1T12G Screw Terminal 12 VDC 8.33 A 12.5 A 1% 0.0 A MBC150-1015G JST 15 VDC 6.67 A 10.0 A 1% 0.0 A MBC150-1T15G Screw Terminal 15 VDC 6.67 A 10.0 A 1% 0.0 A MBC150-1024G JST 24 VDC 4.17 A 6.25 A 1% 0.0 A MBC150-1T24G Screw Terminal 24 VDC 4.17 A 6.25 A 1% 0.0 A MBC150-1048G JST 48 VDC 2.08 A 3.13 A 1% 0.0 A MBC150-1T48G Screw Terminal 48 VDC 2.08 A 3.13 A 1% 6 COVER-201-XBC Metal cover kit accessory Specifications are for nominal input voltage, 25C unless otherwise stated. PARAMETER DESCRIPTION / CONDITION SPECIFICATION Input Voltage Universal 90-264 VAC / 120-390 VDC Input Frequency 47 to 63 Hz 120 VAC: 1.7 A max. Input Current 230 VAC: 0.85 A max. No Load Power 1.2 W 120 VAC: 35 A max. Inrush Current 230 VAC: 65 A max. 120 VAC: < 140 A Leakage Current 230 VAC: < 250 A 120 VAC: 0.99 Power Factor 230 VAC: 0.95 PFC converter (variable) 35 - 250 kHz, 90 kHz typical Switching Frequency Resonant converter (variable) 35 - 250 kHz, 90 kHz typical 1 For Class II (without input Earth pin) add suffix -2 (e.g.: MBC150-1012G-2). 2 Combined output power from V1, VSTBY and VFAN should not exceed the total output power rating. 3 Fan output voltage tolerance is +/-20%. 4 Peak current for fan output is 1 A 5 Ripple is 2% up to 20% load and < 1% above 20% load. Ripple is peak to peak with 20 MHz bandwidth and 10 F (Tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 6 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. tech.support psbel.com